Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC295TP2M — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC295TP2M is a 295.0 W STC (271.0 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.2 V Voc at 25 C, and 43.19 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
271.0 W
Voc @ 25C
39.2 V
Efficiency
18.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC295TP2M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC295TP2M (Mono-c-Si) residential solar systems.

REC Group REC295TP2M delivers 182.1 W/m2 (1.70 percentage points below 19.91% CEC median) and strong 91.9% PTC-to-STC heat retention (#14,464 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft). At -4 F (-20 C), string voltage climbs to 44.33 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W).

Where Does REC Group REC295TP2M Fall Across Listed CEC Models?

Comparison of REC Group REC295TP2M (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC295TP2M (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC295TP: 295.0 W

What Dataset Percentiles Define REC Group REC295TP2M?

Relative ranking of REC Group REC295TP2M across nameplate watts, 91.9% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

REC Group REC295TP2M Engineering BenchmarksPercentile comparison of REC Group REC295TP2M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention91.9%Module Efficiency18.21%

What Do the Dataset Ranks Show for REC Group REC295TP2M?

Summary of REC Group REC295TP2M output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,805

18.21% Aperture Efficiency

Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 91.9% (rank #14,464).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.19 V at -10 C (561.5 V string) and 44.33 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,588 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.2 * (1 + (-0.291/100) * (-10 - 25)) = 43.19 V | OCPD = 1.56 * 9.58 = 14.94 A

Inputs from CEC Modules.csv for REC Group REC295TP2M: Voc=39.2 V, beta_Voc=-0.291%/C, Isc=9.58 A, STC=295.0 W, Area=1.62 m2.

Result: 13 panels max on 600 V (561.5 V); 28 panels for 8 kW (488 sq ft).

What Are the Published CEC Specifications for REC Group REC295TP2M?

Complete CEC test sheet for REC Group REC295TP2M including Isc (9.58 A), Voc (39.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC295TP2M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 271.0 W (91.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.8 V / 9.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.291 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.21% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC295TP2M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC295TP2M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 366 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 488 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 593 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC295TP2M series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the REC Group REC295TP2M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC290TP2M 290.0 W 266.3 W 39.0 V 32.6 V 17.9%
REC Group REC295TP2M 295.0 W 271.0 W 39.2 V 32.8 V 18.21%

How Many REC Group REC295TP2M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC295TP2M (39.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=39.2V and beta_Voc=-0.291%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.33 V 13 panels 576.3 V 22 panels
-10 C (14 F) 43.19 V 13 panels 561.5 V 23 panels
0 C (32 F) 42.05 V 14 panels 588.7 V 23 panels
25 C (77 F STC) 39.2 V 15 panels 588.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC295TP2M?

Four comparable CEC modules such as GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/60295
GCL System Integration Technology Co Ltd
295.0 W Tie (0 W) 39.3 V 18.1% 90.2%
CSI Solar Co Ltd CS3K-295MS
CSI Solar Co Ltd
295.0 W Tie (0 W) 39.1 V 18.4% 93.0%
GCL System Integration Technology Co Ltd GCL-M6/60290
GCL System Integration Technology Co Ltd
290.0 W -5.0 W 39.1 V 17.79% 90.2%
GCL System Integration Technology Co Ltd GCL-P6/60290
GCL System Integration Technology Co Ltd
290.0 W -5.0 W 39.1 V 17.79% 90.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC295TP2M?

Evaluate REC Group REC295TP2M (295.0 W STC, 39.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC295TP2M reaches 44.33 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC295TP2M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC295TP2M 8 kW Residential Fit

Needs 28 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC295TP2M by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

How many REC Group REC295TP2M panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC295TP2M cold Voc rises from 39.2 V to 43.19 V (beta_Voc -0.291%/C), capping a 600 V string at 13 panels (561.5 V).

How much roof area does an 8 kW array of REC Group REC295TP2M need?

An 8 kW DC system uses 28 REC Group REC295TP2M modules (8,260 W STC / 7,588 W PTC), covering roughly 488 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does REC Group REC295TP2M compare against GCL System Integration Technology Co Ltd GCL-M6/60295?

REC Group REC295TP2M outputs 295.0 W STC (39.2 V Voc, rank #16,890 of 21,677), while GCL System Integration Technology Co Ltd GCL-M6/60295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.