Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC295NP — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC295NP is a 295.0 W STC (275.3 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.4 V Voc at 25 C, and 43.07 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
275.3 W
Voc @ 25C
39.4 V
Efficiency
18.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC295NP Compare Against Peer CEC Listings?

How REC Group REC Group REC295NP handles rooftop heat (275.3 W PTC), 8 kW sizing, and cold winter string voltage.

REC Group builds the REC Group REC295NP (Mono-c-Si) as a compact residential or specialty off-grid module delivering 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). Compared against GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Lower 39.4 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 15.23 A overcurrent floor served by a 20 A breaker.

Where Does REC Group REC295NP Fall Across Listed CEC Models?

Where REC Group REC295NP (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC295NP (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC295NP: 295.0 W

What Dataset Percentiles Define REC Group REC295NP?

Percentile placement of REC Group REC295NP across power density (182.1 W/m2), thermal retention, and nameplate STC wattage.

REC Group REC295NP Engineering BenchmarksPercentile comparison of REC Group REC295NP wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention93.3%Module Efficiency18.21%

What Do the Dataset Ranks Show for REC Group REC295NP?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC295NP specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,805

18.21% Aperture Efficiency

Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.07 V at -10 C (559.9 V string) and 44.12 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,708 W PTC; NEC 690.8 OCPD floor is 15.23 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.4 * (1 + (-0.266/100) * (-10 - 25)) = 43.07 V | OCPD = 1.56 * 9.76 = 15.23 A

Inputs from CEC Modules.csv for REC Group REC295NP: Voc=39.4 V, beta_Voc=-0.266%/C, Isc=9.76 A, STC=295.0 W, Area=1.62 m2.

Result: 13 panels max on 600 V (559.9 V); 28 panels for 8 kW (488 sq ft).

What Are the Published CEC Specifications for REC Group REC295NP?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC295NP.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC295NP.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 275.3 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.76 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.7 V / 9.04 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.21% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC295NP Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC295NP (295.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 366 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 488 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 593 sq ft $2,510 $4,245

How Many REC Group REC295NP Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC295NP from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.4V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.12 V 13 panels 573.6 V 22 panels
-10 C (14 F) 43.07 V 13 panels 559.9 V 23 panels
0 C (32 F) 42.02 V 14 panels 588.3 V 23 panels
25 C (77 F STC) 39.4 V 15 panels 591.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC295NP?

Alternative CEC solar modules from competing brands near REC Group REC295NP (295.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60295.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/60295
GCL System Integration Technology Co Ltd
295.0 W Tie (0 W) 39.3 V 18.1% 90.2%
CSI Solar Co Ltd CS3K-295MS
CSI Solar Co Ltd
295.0 W Tie (0 W) 39.1 V 18.4% 93.0%
AXITEC AC-290M/60S
AXITEC
290.0 W -5.0 W 39.42 V 17.79% 91.1%
AXITEC AC-290M/60V
AXITEC
290.0 W -5.0 W 39.42 V 17.79% 91.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC295NP?

Evaluate REC Group REC295NP (295.0 W STC, 39.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC295NP reaches 44.12 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC295NP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC295NP 8 kW Residential Fit

Needs 28 modules (488 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 275.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC295NP by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC295NP?

Multiplying REC Group REC295NP's 9.76 A short-circuit current by 1.56 equals 15.23 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC295NP pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.07 V cold Voc at 14 F and handles 9.76 A Isc; string inverters cap REC Group REC295NP at 13 panels on 600 V.

Is REC Group REC295NP eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC295NP rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.