REC Group REC295NP is a 295.0 W STC (275.3 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.4 V Voc at 25 C, and 43.07 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 275.3 W
- Voc @ 25C
- 39.4 V
- Efficiency
- 18.21%
How Does REC Group REC295NP Compare Against Peer CEC Listings?
How REC Group REC Group REC295NP handles rooftop heat (275.3 W PTC), 8 kW sizing, and cold winter string voltage.
REC Group builds the REC Group REC295NP (Mono-c-Si) as a compact residential or specialty off-grid module delivering 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). Compared against GCL System Integration Technology Co Ltd GCL-M6/60295 (295.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Lower 39.4 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 15.23 A overcurrent floor served by a 20 A breaker.
Where Does REC Group REC295NP Fall Across Listed CEC Models?
Where REC Group REC295NP (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define REC Group REC295NP?
Percentile placement of REC Group REC295NP across power density (182.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for REC Group REC295NP?
Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC295NP specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.21% Aperture Efficiency
Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.07 V at -10 C (559.9 V string) and 44.12 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,708 W PTC; NEC 690.8 OCPD floor is 15.23 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.4 * (1 + (-0.266/100) * (-10 - 25)) = 43.07 V | OCPD = 1.56 * 9.76 = 15.23 A
Inputs from CEC Modules.csv for REC Group REC295NP: Voc=39.4 V, beta_Voc=-0.266%/C, Isc=9.76 A, STC=295.0 W, Area=1.62 m2.
Result: 13 panels max on 600 V (559.9 V); 28 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for REC Group REC295NP?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC295NP.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 275.3 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.76 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.7 V / 9.04 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.21% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC295NP Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC295NP (295.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 366 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 488 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 593 sq ft | $2,510 | $4,245 |
How Many REC Group REC295NP Modules Fit in a Cold-Weather String?
Maximum series module counts for REC Group REC295NP from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.12 V | 13 panels | 573.6 V | 22 panels |
| -10 C (14 F) | 43.07 V | 13 panels | 559.9 V | 23 panels |
| 0 C (32 F) | 42.02 V | 14 panels | 588.3 V | 23 panels |
| 25 C (77 F STC) | 39.4 V | 15 panels | 591.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC295NP?
Alternative CEC solar modules from competing brands near REC Group REC295NP (295.0 W), including GCL System Integration Technology Co Ltd GCL-M6/60295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| CSI Solar Co Ltd CS3K-295MS CSI Solar Co Ltd |
295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| AXITEC AC-290M/60S AXITEC |
290.0 W | -5.0 W | 39.42 V | 17.79% | 91.1% |
| AXITEC AC-290M/60V AXITEC |
290.0 W | -5.0 W | 39.42 V | 17.79% | 91.1% |
What Are the Design Limits and Best-Fit Uses for REC Group REC295NP?
Evaluate REC Group REC295NP (295.0 W STC, 39.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC295NP reaches 44.12 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of REC Group REC295NP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC295NP 8 kW Residential Fit
Needs 28 modules (488 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 275.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC295NP by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC295NP?
Multiplying REC Group REC295NP's 9.76 A short-circuit current by 1.56 equals 15.23 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can REC Group REC295NP pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.07 V cold Voc at 14 F and handles 9.76 A Isc; string inverters cap REC Group REC295NP at 13 panels on 600 V.
Is REC Group REC295NP eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC295NP rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)