Skip to main content
WireAndSun
Calculators
CEC PV Module

Qcells North America QPRO-G3 260 — CEC Solar Module Specifications

Manufacturer: Qcells North America Registry: CEC Verified Engineering Specification

Qcells North America QPRO-G3 260 is a 260.0 W STC (236.5 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.73% efficiency, 38.21 V Voc at 25 C, and 42.49 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
236.5 W
Voc @ 25C
38.21 V
Efficiency
15.73%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Qcells North America QPRO-G3 260 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Qcells North America QPRO-G3 260 (Multi-c-Si) residential solar systems.

Qcells North America QPRO-G3 260 delivers 157.3 W/m2 (4.18 percentage points below 19.91% CEC median) and typical 91.0% PTC-to-STC thermal output (236.5 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (552 sq ft). At -4 F (-20 C), string voltage climbs to 43.71 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Centrosolar America DM60 260 (260.0 W).

Where Does Qcells North America QPRO-G3 260 Fall Across Listed CEC Models?

Comparison of Qcells North America QPRO-G3 260 (260.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Qcells North America QPRO-G3 260 (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCQcells North Ameri: 260.0 W

What Dataset Percentiles Define Qcells North America QPRO-G3 260?

Relative ranking of Qcells North America QPRO-G3 260 across nameplate watts, 91.0% PTC thermal ratio, and module aperture efficiency.

Qcells North America QPRO-G3 260 Engineering BenchmarksPercentile comparison of Qcells North America QPRO-G3 260 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention91.0%Module Efficiency15.73%

What Do the Dataset Ranks Show for Qcells North America QPRO-G3 260?

Summary of Qcells North America QPRO-G3 260 output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,566

15.73% Aperture Efficiency

Power density 157.3 W/m2 (4.18 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.49 V at -10 C (594.9 V string) and 43.71 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 51.2 m2 (552 sq ft) producing 7,332 W PTC; NEC 690.8 OCPD floor is 14.23 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.21 * (1 + (-0.32/100) * (-10 - 25)) = 42.49 V | OCPD = 1.56 * 9.12 = 14.23 A

Inputs from CEC Modules.csv for Qcells North America QPRO-G3 260: Voc=38.21 V, beta_Voc=-0.32%/C, Isc=9.12 A, STC=260.0 W, Area=1.653 m2.

Result: 14 panels max on 600 V (594.9 V); 31 panels for 8 kW (552 sq ft).

What Are the Published CEC Specifications for Qcells North America QPRO-G3 260?

Complete CEC test sheet for Qcells North America QPRO-G3 260 including Isc (9.12 A), Voc (38.21 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Qcells North America QPRO-G3 260.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 236.5 W (91.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.21 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.18 V / 8.7 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.73% (1.653 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Qcells North America QPRO-G3 260 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Qcells North America QPRO-G3 260.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 427 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 552 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 694 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Qcells North America Series?

Related Qcells North America power steps and black/silver trims consolidated into this Qcells North America QPRO-G3 260 series guide.

Sibling CEC listings grouped into the Qcells North America QPRO-G3 260 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Qcells North America QPRO-G3 250 250.0 W 227.1 W 37.78 V 29.89 V 15.12%
Qcells North America QPRO-G3 255 255.0 W 231.8 W 37.99 V 30.04 V 15.43%
Qcells North America QPRO-G3 260 260.0 W 236.5 W 38.21 V 30.18 V 15.73%
Qcells North America QPRO-G3 265 265.0 W 241.1 W 38.43 V 30.32 V 16.03%

How Many Qcells North America QPRO-G3 260 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Qcells North America QPRO-G3 260 (38.21 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.21V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.71 V 13 panels 568.2 V 22 panels
-10 C (14 F) 42.49 V 14 panels 594.9 V 23 panels
0 C (32 F) 41.27 V 14 panels 577.8 V 24 panels
25 C (77 F STC) 38.21 V 15 panels 573.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Qcells North America QPRO-G3 260?

Four comparable CEC modules such as Centrosolar America DM60 260 (260.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DM60 260
Centrosolar America
260.0 W Tie (0 W) 38.2 V 15.86% 90.8%
Centrosolar America DP60 260
Centrosolar America
260.0 W Tie (0 W) 38.28 V 15.86% 90.2%
BYD Company Limited BYD 260P6C-30
BYD Company Limited
260.0 W Tie (0 W) 38.38 V 15.98% 90.4%
BYD Company Limited BYD260P6K-30
BYD Company Limited
260.0 W Tie (0 W) 38.38 V 15.95% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Qcells North America QPRO-G3 260?

Evaluate Qcells North America QPRO-G3 260 (260.0 W STC, 38.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Qcells North America QPRO-G3 260 reaches 43.71 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 552 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (552 sq ft).
  • 2026 tax credit baseline: cash residential installs of Qcells North America QPRO-G3 260 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Qcells North America QPRO-G3 260 8 kW Residential Fit

Needs 31 modules (552 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America DM60 260.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 236.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Qcells North America QPRO-G3 260 by Qcells North America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Qcells North America QPRO-G3 260 panels fit on a 600 V winter solar string?

At -10 C (14 F), Qcells North America QPRO-G3 260 cold Voc rises from 38.21 V to 42.49 V (beta_Voc -0.32%/C), capping a 600 V string at 14 panels (594.9 V).

How much roof area does an 8 kW array of Qcells North America QPRO-G3 260 need?

An 8 kW DC system uses 31 Qcells North America QPRO-G3 260 modules (8,060 W STC / 7,332 W PTC), covering roughly 552 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Qcells North America QPRO-G3 260 compare against Centrosolar America DM60 260?

Qcells North America QPRO-G3 260 outputs 260.0 W STC (38.21 V Voc, rank #19,146 of 21,677), while Centrosolar America DM60 260 delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.