Qcells North America QPLUS L-G42/TAA 340 is a 340.0 W STC (312.2 W PTC) Multi-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.05% efficiency, 47.07 V Voc at 25 C, and 51.91 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 340.0 W
- PTC Wattage
- 312.2 W
- Voc @ 25C
- 47.07 V
- Efficiency
- 17.05%
How Does Qcells North America QPLUS L-G42/TAA 340 Compare Against Peer CEC Listings?
Solar engineering breakdown for Qcells North America QPLUS L-G42/TAA 340: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Qcells North America and peers, Qcells North America QPLUS L-G42/TAA 340 stands 61.2 W above the 278.8 W Multi-c-Si median and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,532-$2,553/yr in baseline US bill offset. Mid-range 47.07 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Qcells North America QPLUS L-G42/TAA 340 Fall Across Listed CEC Models?
Distribution marker showing Qcells North America QPLUS L-G42/TAA 340 (340.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Qcells North America QPLUS L-G42/TAA 340?
Dataset percentiles tracking Qcells North America QPLUS L-G42/TAA 340 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Qcells North America QPLUS L-G42/TAA 340?
Benchmark highlights for Qcells North America QPLUS L-G42/TAA 340 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
340.0 W STC · Higher Than 36.1%
340.0 W STC (-45.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.05% Aperture Efficiency
Power density 170.5 W/m2 (2.86 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.91 V at -10 C (571.0 V string) and 53.3 V at -20 C (11 max).
24 Panels = 8,160 W STC
Occupies 47.9 m2 (515 sq ft) producing 7,493 W PTC; NEC 690.8 OCPD floor is 14.96 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.07 * (1 + (-0.294/100) * (-10 - 25)) = 51.91 V | OCPD = 1.56 * 9.59 = 14.96 A
Inputs from CEC Modules.csv for Qcells North America QPLUS L-G42/TAA 340: Voc=47.07 V, beta_Voc=-0.294%/C, Isc=9.59 A, STC=340.0 W, Area=1.994 m2.
Result: 11 panels max on 600 V (571.0 V); 24 panels for 8 kW (515 sq ft).
What Are the Published CEC Specifications for Qcells North America QPLUS L-G42/TAA 340?
Official CEC datasheet figures for Qcells North America QPLUS L-G42/TAA 340 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 312.2 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.07 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.63 V / 9.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.294 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.05% (1.994 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Qcells North America QPLUS L-G42/TAA 340 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Qcells North America QPLUS L-G42/TAA 340 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.12 kW | 386 sq ft | $1,532 | $2,590 |
| 8 kW Class | 24 | 8.16 kW | 515 sq ft | $2,042 | $3,454 |
| 10 kW Class | 30 | 10.2 kW | 644 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This Qcells North America Series?
Consolidated Qcells North America wattage variants sharing the Qcells North America QPLUS L-G42/TAA 340 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Qcells North America QPLUS L-G42/TAA 335 | 335.0 W | 307.5 W | 46.81 V | 37.33 V | 16.8% |
| Qcells North America QPLUS L-G42/TAA 340 | 340.0 W | 312.2 W | 47.07 V | 37.63 V | 17.05% |
| Qcells North America QPLUS L-G42/TAA 345 | 345.0 W | 316.9 W | 47.46 V | 37.93 V | 17.3% |
How Many Qcells North America QPLUS L-G42/TAA 340 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Qcells North America QPLUS L-G42/TAA 340 (51.91 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.3 V | 11 panels | 586.3 V | 18 panels |
| -10 C (14 F) | 51.91 V | 11 panels | 571.0 V | 19 panels |
| 0 C (32 F) | 50.53 V | 11 panels | 555.8 V | 19 panels |
| 25 C (77 F STC) | 47.07 V | 12 panels | 564.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Qcells North America QPLUS L-G42/TAA 340?
Competing CEC solar panels closest to Qcells North America QPLUS L-G42/TAA 340 in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
340.0 W | Tie (0 W) | 46.97 V | 17.52% | 91.0% |
| Advance Power API-M340 Advance Power |
340.0 W | Tie (0 W) | 47.18 V | 17.53% | 91.7% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
340.0 W | Tie (0 W) | 46.91 V | 17.68% | 91.4% |
| DEHUI SOLAR POWER INC DH-72M-340W DEHUI SOLAR POWER INC |
340.0 W | Tie (0 W) | 47.3 V | 17.68% | 91.3% |
What Are the Design Limits and Best-Fit Uses for Qcells North America QPLUS L-G42/TAA 340?
Evaluate Qcells North America QPLUS L-G42/TAA 340 (340.0 W STC, 47.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Qcells North America QPLUS L-G42/TAA 340 reaches 53.3 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 515 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (515 sq ft).
- 2026 tax credit baseline: cash residential installs of Qcells North America QPLUS L-G42/TAA 340 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Qcells North America QPLUS L-G42/TAA 340 8 kW Residential Fit
Needs 24 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 312.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Qcells North America QPLUS L-G42/TAA 340 by Qcells North America grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Qcells North America QPLUS L-G42/TAA 340?
Multiplying Qcells North America QPLUS L-G42/TAA 340's 9.59 A short-circuit current by 1.56 equals 14.96 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Qcells North America QPLUS L-G42/TAA 340 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.91 V cold Voc at 14 F and handles 9.59 A Isc; string inverters cap Qcells North America QPLUS L-G42/TAA 340 at 11 panels on 600 V.
Is Qcells North America QPLUS L-G42/TAA 340 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Qcells North America QPLUS L-G42/TAA 340 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)