PT NUSA SOLAR INDONESIA NS415M10T-B54yy is a 415.0 W STC (389.7 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.28% efficiency, 38.84 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 389.7 W
- Voc @ 25C
- 38.84 V
- Efficiency
- 21.28%
How Does PT NUSA SOLAR INDONESIA NS415M10T-B54yy Compare Against Peer CEC Listings?
How PT NUSA SOLAR INDONESIA PT NUSA SOLAR INDONESIA NS415M10T-B54yy handles rooftop heat (389.7 W PTC), 8 kW sizing, and cold winter string voltage.
PT NUSA SOLAR INDONESIA builds the PT NUSA SOLAR INDONESIA NS415M10T-B54yy (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). Compared against Boviet Solar Technology Co Ltd BVM7609M-415-H-HC (415.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Lower 38.84 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.33 A overcurrent floor served by a 25 A breaker.
Where Does PT NUSA SOLAR INDONESIA NS415M10T-B54yy Fall Across Listed CEC Models?
Where PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PT NUSA SOLAR INDONESIA NS415M10T-B54yy?
Percentile placement of PT NUSA SOLAR INDONESIA NS415M10T-B54yy across power density (212.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?
Four critical engineering numbers homeowners and solar installers check first when reviewing PT NUSA SOLAR INDONESIA NS415M10T-B54yy specifications.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.28% Aperture Efficiency
Power density 212.8 W/m2 (1.37 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 43.05 V at -20 C (13 max).
20 Panels = 8,300 W STC
Occupies 39.0 m2 (420 sq ft) producing 7,794 W PTC; NEC 690.8 OCPD floor is 21.33 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.84 * (1 + (-0.241/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 13.67 = 21.33 A
Inputs from CEC Modules.csv for PT NUSA SOLAR INDONESIA NS415M10T-B54yy: Voc=38.84 V, beta_Voc=-0.241%/C, Isc=13.67 A, STC=415.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (589.7 V); 20 panels for 8 kW (420 sq ft).
What Are the Published CEC Specifications for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PT NUSA SOLAR INDONESIA NS415M10T-B54yy.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 389.7 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.84 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.23 V / 12.89 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.241 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.28% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT NUSA SOLAR INDONESIA NS415M10T-B54yy Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 315 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 420 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 525 sq ft | $2,598 | $4,393 |
Which Sibling Wattage & Trim Variants Belong to This PT NUSA SOLAR INDONESIA Series?
All closely matched PT NUSA SOLAR INDONESIA wattages and cosmetic trims sharing the PT NUSA SOLAR INDONESIA NS415M10T-B54yy architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT NUSA SOLAR INDONESIA NS405M10T-B54yy | 405.0 W | 380.1 W | 38.44 V | 31.83 V | 20.77% |
| PT NUSA SOLAR INDONESIA NS410M10T-B54yy | 410.0 W | 384.9 W | 38.64 V | 32.03 V | 21.03% |
| PT NUSA SOLAR INDONESIA NS415M10T-B54yy | 415.0 W | 389.7 W | 38.84 V | 32.23 V | 21.28% |
| PT NUSA SOLAR INDONESIA NS420M10T-B54yy | 420.0 W | 394.6 W | 39.04 V | 32.43 V | 21.54% |
How Many PT NUSA SOLAR INDONESIA NS415M10T-B54yy Modules Fit in a Cold-Weather String?
Maximum series module counts for PT NUSA SOLAR INDONESIA NS415M10T-B54yy from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.05 V | 13 panels | 559.6 V | 23 panels |
| -10 C (14 F) | 42.12 V | 14 panels | 589.7 V | 23 panels |
| 0 C (32 F) | 41.18 V | 14 panels | 576.5 V | 24 panels |
| 25 C (77 F STC) | 38.84 V | 15 panels | 582.6 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to PT NUSA SOLAR INDONESIA NS415M10T-B54yy?
Alternative CEC solar modules from competing brands near PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W), including Boviet Solar Technology Co Ltd BVM7609M-415-H-HC.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM7609M-415-H-HC Boviet Solar Technology Co Ltd |
415.0 W | Tie (0 W) | 38.47 V | 19.21% | 94.7% |
| AXITEC AC-415TGB/108BB AXITEC |
415.0 W | Tie (0 W) | 38.04 V | 21.84% | 94.9% |
| Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| Aptos Solar Technology LLC DNA-108-BF10-415W Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |
What Are the Design Limits and Best-Fit Uses for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?
Evaluate PT NUSA SOLAR INDONESIA NS415M10T-B54yy (415.0 W STC, 38.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT NUSA SOLAR INDONESIA NS415M10T-B54yy reaches 43.05 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT NUSA SOLAR INDONESIA NS415M10T-B54yy carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT NUSA SOLAR INDONESIA NS415M10T-B54yy 8 kW Residential Fit
Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM7609M-415-H-HC.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 389.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT NUSA SOLAR INDONESIA NS415M10T-B54yy by PT NUSA SOLAR INDONESIA grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PT NUSA SOLAR INDONESIA NS415M10T-B54yy?
Multiplying PT NUSA SOLAR INDONESIA NS415M10T-B54yy's 13.67 A short-circuit current by 1.56 equals 21.33 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can PT NUSA SOLAR INDONESIA NS415M10T-B54yy pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.12 V cold Voc at 14 F and handles 13.67 A Isc; string inverters cap PT NUSA SOLAR INDONESIA NS415M10T-B54yy at 14 panels on 600 V.
Is PT NUSA SOLAR INDONESIA NS415M10T-B54yy eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT NUSA SOLAR INDONESIA NS415M10T-B54yy rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)