Skip to main content
WireAndSun
Calculators
CEC PV Module

PT IDN SOLAR TECH NUSA144H-440MB — CEC Solar Module Specifications

Manufacturer: PT IDN SOLAR TECH Registry: CEC Verified Engineering Specification

PT IDN SOLAR TECH NUSA144H-440MB is a 440.0 W STC (411.1 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.18% efficiency, 49.9 V Voc at 25 C, and 54.81 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
411.1 W
Voc @ 25C
49.9 V
Efficiency
20.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PT IDN SOLAR TECH NUSA144H-440MB Compare Against Peer CEC Listings?

Engineering position of PT IDN SOLAR TECH NUSA144H-440MB (440.0 W STC) vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, PT IDN SOLAR TECH NUSA144H-440MB pairs strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677) with 49.9 V nominal Voc. An 8 kW residential build (8,360 W DC, 7,811 W PTC) saves ~$2,092/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W offers a 440.0 W alternative.

Where Does PT IDN SOLAR TECH NUSA144H-440MB Fall Across Listed CEC Models?

Plots PT IDN SOLAR TECH NUSA144H-440MB at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PT IDN SOLAR TECH NUSA144H-440MB (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPT IDN SOLAR TECH : 440.0 W

What Dataset Percentiles Define PT IDN SOLAR TECH NUSA144H-440MB?

Benchmarks PT IDN SOLAR TECH NUSA144H-440MB on STC wattage, thermal PTC/STC retention, and 20.18 aperture conversion efficiency against CEC peers.

PT IDN SOLAR TECH NUSA144H-440MB Engineering BenchmarksPercentile comparison of PT IDN SOLAR TECH NUSA144H-440MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention93.4%Module Efficiency20.18%

What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA144H-440MB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PT IDN SOLAR TECH NUSA144H-440MB by PT IDN SOLAR TECH.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,844

20.18% Aperture Efficiency

Power density 201.8 W/m2 (0.27 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.81 V at -10 C (548.1 V string) and 56.21 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 41.4 m2 (446 sq ft) producing 7,811 W PTC; NEC 690.8 OCPD floor is 17.52 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.9 * (1 + (-0.281/100) * (-10 - 25)) = 54.81 V | OCPD = 1.56 * 11.23 = 17.52 A

Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA144H-440MB: Voc=49.9 V, beta_Voc=-0.281%/C, Isc=11.23 A, STC=440.0 W, Area=2.18 m2.

Result: 10 panels max on 600 V (548.1 V); 19 panels for 8 kW (446 sq ft).

What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA144H-440MB?

Laboratory test ratings recorded for PT IDN SOLAR TECH NUSA144H-440MB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PT IDN SOLAR TECH NUSA144H-440MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 411.1 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.2 V / 10.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.18% (2.18 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PT IDN SOLAR TECH NUSA144H-440MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (446 sq ft at 8 kW), and estimated Year-1 electric bill offset for PT IDN SOLAR TECH NUSA144H-440MB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 329 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 446 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 540 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?

Sibling wattage bins and frame colors grouped with PT IDN SOLAR TECH NUSA144H-440MB under PT IDN SOLAR TECH to prevent duplicate spec pages.

Sibling CEC listings grouped into the PT IDN SOLAR TECH NUSA144H-440MB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PT IDN SOLAR TECH NUSA144H-430MB 430.0 W 401.5 W 49.5 V 40.8 V 19.72%
PT IDN SOLAR TECH NUSA144H-435MB 435.0 W 406.3 W 49.7 V 41.0 V 19.95%
PT IDN SOLAR TECH NUSA144H-440MB 440.0 W 411.1 W 49.9 V 41.2 V 20.18%
PT IDN SOLAR TECH NUSA144H-445MB 445.0 W 415.9 W 50.1 V 41.4 V 20.41%

How Many PT IDN SOLAR TECH NUSA144H-440MB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PT IDN SOLAR TECH NUSA144H-440MB (beta_Voc -0.281%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.9V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.21 V 10 panels 562.1 V 17 panels
-10 C (14 F) 54.81 V 10 panels 548.1 V 18 panels
0 C (32 F) 53.41 V 11 panels 587.5 V 18 panels
25 C (77 F STC) 49.9 V 12 panels 598.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA144H-440MB?

Closest cross-brand CEC competitors to PT IDN SOLAR TECH NUSA144H-440MB matched near 440.0 W STC and 49.9 V Voc, led by Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.6 V 20.75% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.3 V 20.56% 92.6%
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
Bluesun Solar CoLtd BSM440M-72HPH
Bluesun Solar CoLtd
440.0 W Tie (0 W) 49.2 V 20.28% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA144H-440MB?

Evaluate PT IDN SOLAR TECH NUSA144H-440MB (440.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA144H-440MB reaches 56.21 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 446 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (446 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA144H-440MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PT IDN SOLAR TECH NUSA144H-440MB 8 kW Residential Fit

Needs 19 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 411.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PT IDN SOLAR TECH NUSA144H-440MB by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for PT IDN SOLAR TECH NUSA144H-440MB?

Multiplying PT IDN SOLAR TECH NUSA144H-440MB's 11.23 A short-circuit current by 1.56 equals 17.52 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can PT IDN SOLAR TECH NUSA144H-440MB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.81 V cold Voc at 14 F and handles 11.23 A Isc; string inverters cap PT IDN SOLAR TECH NUSA144H-440MB at 10 panels on 600 V.

Is PT IDN SOLAR TECH NUSA144H-440MB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PT IDN SOLAR TECH NUSA144H-440MB rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.