PT IDN SOLAR TECH NUSA144H-405M is a 405.0 W STC (378.3 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.15% efficiency, 49.8 V Voc at 25 C, and 55.36 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 378.3 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 20.15%
How Does PT IDN SOLAR TECH NUSA144H-405M Compare Against Peer CEC Listings?
Solar engineering breakdown for PT IDN SOLAR TECH NUSA144H-405M: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 405.0 W STC and 378.3 W PTC, PT IDN SOLAR TECH NUSA144H-405M sits +20.0 W vs all-CEC median (top 43.4%; higher than 56.6% of peers) among 21,677 listed modules. Power density reaches 201.5 W/m2 (0.24 percentage points above 19.91% CEC median). Higher 49.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-405L-H rates 405.0 W.
Where Does PT IDN SOLAR TECH NUSA144H-405M Fall Across Listed CEC Models?
Distribution marker showing PT IDN SOLAR TECH NUSA144H-405M (405.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define PT IDN SOLAR TECH NUSA144H-405M?
Dataset percentiles tracking PT IDN SOLAR TECH NUSA144H-405M power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA144H-405M?
Benchmark highlights for PT IDN SOLAR TECH NUSA144H-405M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.15% Aperture Efficiency
Power density 201.5 W/m2 (0.24 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.36 V at -10 C (553.6 V string) and 56.95 V at -20 C (10 max).
20 Panels = 8,100 W STC
Occupies 40.2 m2 (433 sq ft) producing 7,566 W PTC; NEC 690.8 OCPD floor is 16.1 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.319/100) * (-10 - 25)) = 55.36 V | OCPD = 1.56 * 10.32 = 16.1 A
Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA144H-405M: Voc=49.8 V, beta_Voc=-0.319%/C, Isc=10.32 A, STC=405.0 W, Area=2.01 m2.
Result: 10 panels max on 600 V (553.6 V); 20 panels for 8 kW (433 sq ft).
What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA144H-405M?
Official CEC datasheet figures for PT IDN SOLAR TECH NUSA144H-405M (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 378.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.5 V / 9.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.319 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.15% (2.01 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT IDN SOLAR TECH NUSA144H-405M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PT IDN SOLAR TECH NUSA144H-405M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 325 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 433 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 541 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?
Consolidated PT IDN SOLAR TECH wattage variants sharing the PT IDN SOLAR TECH NUSA144H-405M mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT IDN SOLAR TECH NUSA144H-400M | 400.0 W | 373.5 W | 49.5 V | 41.3 V | 19.9% |
| PT IDN SOLAR TECH NUSA144H-405M | 405.0 W | 378.3 W | 49.8 V | 41.5 V | 20.15% |
| PT IDN SOLAR TECH NUSA144H-410M | 410.0 W | 383.1 W | 50.1 V | 41.8 V | 20.4% |
How Many PT IDN SOLAR TECH NUSA144H-405M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PT IDN SOLAR TECH NUSA144H-405M (55.36 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.95 V | 10 panels | 569.5 V | 17 panels |
| -10 C (14 F) | 55.36 V | 10 panels | 553.6 V | 18 panels |
| 0 C (32 F) | 53.77 V | 11 panels | 591.5 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA144H-405M?
Competing CEC solar panels closest to PT IDN SOLAR TECH NUSA144H-405M in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-405L-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 20.35% | 93.3% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 19.95% | 93.6% |
| CSI Solar Co Ltd CS3U-405MS CSI Solar Co Ltd |
405.0 W | Tie (0 W) | 49.3 V | 21.09% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | Tie (0 W) | 49.2 V | 21.2% | 92.6% |
What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA144H-405M?
Evaluate PT IDN SOLAR TECH NUSA144H-405M (405.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA144H-405M reaches 56.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 433 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (433 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA144H-405M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT IDN SOLAR TECH NUSA144H-405M 8 kW Residential Fit
Needs 20 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT IDN SOLAR TECH NUSA144H-405M by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.
How many PT IDN SOLAR TECH NUSA144H-405M panels fit on a 600 V winter solar string?
At -10 C (14 F), PT IDN SOLAR TECH NUSA144H-405M cold Voc rises from 49.8 V to 55.36 V (beta_Voc -0.319%/C), capping a 600 V string at 10 panels (553.6 V).
How much roof area does an 8 kW array of PT IDN SOLAR TECH NUSA144H-405M need?
An 8 kW DC system uses 20 PT IDN SOLAR TECH NUSA144H-405M modules (8,100 W STC / 7,566 W PTC), covering roughly 433 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does PT IDN SOLAR TECH NUSA144H-405M compare against Boviet Solar Technology Co Ltd BVM6612M-405L-H?
PT IDN SOLAR TECH NUSA144H-405M outputs 405.0 W STC (49.8 V Voc, rank #8,961 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-405L-H delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)