PT IDN SOLAR TECH NUSA120H-455MT is a 455.0 W STC (428.8 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.06% efficiency, 41.33 V Voc at 25 C, and 45.47 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 428.8 W
- Voc @ 25C
- 41.33 V
- Efficiency
- 21.06%
How Does PT IDN SOLAR TECH NUSA120H-455MT Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT IDN SOLAR TECH NUSA120H-455MT (Mono-c-Si) residential solar systems.
PT IDN SOLAR TECH NUSA120H-455MT delivers 210.6 W/m2 (1.15 percentage points above 19.91% CEC median) and strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 46.65 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with CertainTeed CTM10455HC11-06 (455.0 W).
Where Does PT IDN SOLAR TECH NUSA120H-455MT Fall Across Listed CEC Models?
Comparison of PT IDN SOLAR TECH NUSA120H-455MT (455.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define PT IDN SOLAR TECH NUSA120H-455MT?
Relative ranking of PT IDN SOLAR TECH NUSA120H-455MT across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA120H-455MT?
Summary of PT IDN SOLAR TECH NUSA120H-455MT output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.06% Aperture Efficiency
Power density 210.6 W/m2 (1.15 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.47 V at -10 C (591.1 V string) and 46.65 V at -20 C (12 max).
18 Panels = 8,190 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,718 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.33 * (1 + (-0.286/100) * (-10 - 25)) = 45.47 V | OCPD = 1.56 * 13.93 = 21.73 A
Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA120H-455MT: Voc=41.33 V, beta_Voc=-0.286%/C, Isc=13.93 A, STC=455.0 W, Area=2.16 m2.
Result: 13 panels max on 600 V (591.1 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA120H-455MT?
Complete CEC test sheet for PT IDN SOLAR TECH NUSA120H-455MT including Isc (13.93 A), Voc (41.33 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 428.8 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.06 V / 13.36 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.286 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.06% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT IDN SOLAR TECH NUSA120H-455MT Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT IDN SOLAR TECH NUSA120H-455MT.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 326 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 419 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 512 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?
Related PT IDN SOLAR TECH power steps and black/silver trims consolidated into this PT IDN SOLAR TECH NUSA120H-455MT series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT IDN SOLAR TECH NUSA120H-450MT | 450.0 W | 423.9 W | 41.18 V | 33.91 V | 20.83% |
| PT IDN SOLAR TECH NUSA120H-455MT | 455.0 W | 428.8 W | 41.33 V | 34.06 V | 21.06% |
| PT IDN SOLAR TECH NUSA120H-460MT | 460.0 W | 433.6 W | 41.48 V | 34.2 V | 21.3% |
How Many PT IDN SOLAR TECH NUSA120H-455MT Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for PT IDN SOLAR TECH NUSA120H-455MT (41.33 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.65 V | 12 panels | 559.8 V | 21 panels |
| -10 C (14 F) | 45.47 V | 13 panels | 591.1 V | 21 panels |
| 0 C (32 F) | 44.29 V | 13 panels | 575.8 V | 22 panels |
| 25 C (77 F STC) | 41.33 V | 14 panels | 578.6 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA120H-455MT?
Four comparable CEC modules such as CertainTeed CTM10455HC11-06 (455.0 W) for side-by-side solar quote checks. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10455HC11-06 CertainTeed |
455.0 W | Tie (0 W) | 41.33 V | 21.06% | 93.8% |
| Energate Energy Inc EG-120L455W Energate Energy Inc |
455.0 W | Tie (0 W) | 41.33 V | 21.26% | 93.8% |
| Energate Enerji retim San A EG-120L455W Energate Enerji retim San A |
455.0 W | Tie (0 W) | 41.33 V | 21.26% | 93.8% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
455.0 W | Tie (0 W) | 41.3 V | 21.26% | 92.9% |
What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA120H-455MT?
Evaluate PT IDN SOLAR TECH NUSA120H-455MT (455.0 W STC, 41.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA120H-455MT reaches 46.65 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA120H-455MT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT IDN SOLAR TECH NUSA120H-455MT 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CTM10455HC11-06.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 428.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT IDN SOLAR TECH NUSA120H-455MT by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.
How many PT IDN SOLAR TECH NUSA120H-455MT panels fit on a 600 V winter solar string?
At -10 C (14 F), PT IDN SOLAR TECH NUSA120H-455MT cold Voc rises from 41.33 V to 45.47 V (beta_Voc -0.286%/C), capping a 600 V string at 13 panels (591.1 V).
How much roof area does an 8 kW array of PT IDN SOLAR TECH NUSA120H-455MT need?
An 8 kW DC system uses 18 PT IDN SOLAR TECH NUSA120H-455MT modules (8,190 W STC / 7,718 W PTC), covering roughly 419 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does PT IDN SOLAR TECH NUSA120H-455MT compare against CertainTeed CTM10455HC11-06?
PT IDN SOLAR TECH NUSA120H-455MT outputs 455.0 W STC (41.33 V Voc, rank #5,417 of 21,677), while CertainTeed CTM10455HC11-06 delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)