PT IDN SOLAR TECH NUSA120H-455M is a 455.0 W STC (426.8 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.06% efficiency, 41.33 V Voc at 25 C, and 45.26 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 426.8 W
- Voc @ 25C
- 41.33 V
- Efficiency
- 21.06%
How Does PT IDN SOLAR TECH NUSA120H-455M Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PT IDN SOLAR TECH NUSA120H-455M (Mono-c-Si) residential solar systems.
Homeowners evaluating PT IDN SOLAR TECH NUSA120H-455M need 14 panels for 6 kW or 18 panels (419 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.272%/C) pushes open-circuit voltage to 45.26 V at 14 F and 46.39 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does PT IDN SOLAR TECH NUSA120H-455M Fall Across Listed CEC Models?
Comparison of PT IDN SOLAR TECH NUSA120H-455M (455.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define PT IDN SOLAR TECH NUSA120H-455M?
Relative ranking of PT IDN SOLAR TECH NUSA120H-455M across nameplate watts, 93.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for PT IDN SOLAR TECH NUSA120H-455M?
Summary of PT IDN SOLAR TECH NUSA120H-455M output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.06% Aperture Efficiency
Power density 210.6 W/m2 (1.15 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.26 V at -10 C (588.4 V string) and 46.39 V at -20 C (12 max).
18 Panels = 8,190 W STC
Occupies 38.9 m2 (419 sq ft) producing 7,682 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.33 * (1 + (-0.272/100) * (-10 - 25)) = 45.26 V | OCPD = 1.56 * 13.93 = 21.73 A
Inputs from CEC Modules.csv for PT IDN SOLAR TECH NUSA120H-455M: Voc=41.33 V, beta_Voc=-0.272%/C, Isc=13.93 A, STC=455.0 W, Area=2.16 m2.
Result: 13 panels max on 600 V (588.4 V); 18 panels for 8 kW (419 sq ft).
What Are the Published CEC Specifications for PT IDN SOLAR TECH NUSA120H-455M?
Complete CEC test sheet for PT IDN SOLAR TECH NUSA120H-455M including Isc (13.93 A), Voc (41.33 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 426.8 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.33 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.93 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.06 V / 13.36 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.06% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PT IDN SOLAR TECH NUSA120H-455M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PT IDN SOLAR TECH NUSA120H-455M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 326 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 419 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 512 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This PT IDN SOLAR TECH Series?
Related PT IDN SOLAR TECH power steps and black/silver trims consolidated into this PT IDN SOLAR TECH NUSA120H-455M series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PT IDN SOLAR TECH NUSA120H-450M | 450.0 W | 422.0 W | 41.18 V | 33.91 V | 20.83% |
| PT IDN SOLAR TECH NUSA120H-455M | 455.0 W | 426.8 W | 41.33 V | 34.06 V | 21.06% |
| PT IDN SOLAR TECH NUSA120H-460M | 460.0 W | 431.6 W | 41.48 V | 34.2 V | 21.3% |
How Many PT IDN SOLAR TECH NUSA120H-455M Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for PT IDN SOLAR TECH NUSA120H-455M (41.33 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.39 V | 12 panels | 556.7 V | 21 panels |
| -10 C (14 F) | 45.26 V | 13 panels | 588.4 V | 22 panels |
| 0 C (32 F) | 44.14 V | 13 panels | 573.8 V | 22 panels |
| 25 C (77 F STC) | 41.33 V | 14 panels | 578.6 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to PT IDN SOLAR TECH NUSA120H-455M?
Four comparable CEC modules such as CertainTeed CTM10455HC11-06 (455.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10455HC11-06 CertainTeed |
455.0 W | Tie (0 W) | 41.33 V | 21.06% | 93.8% |
| Energate Energy Inc EG-120L455W Energate Energy Inc |
455.0 W | Tie (0 W) | 41.33 V | 21.26% | 93.8% |
| Energate Enerji retim San A EG-120L455W Energate Enerji retim San A |
455.0 W | Tie (0 W) | 41.33 V | 21.26% | 93.8% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
455.0 W | Tie (0 W) | 41.3 V | 21.26% | 92.9% |
What Are the Design Limits and Best-Fit Uses for PT IDN SOLAR TECH NUSA120H-455M?
Evaluate PT IDN SOLAR TECH NUSA120H-455M (455.0 W STC, 41.33 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PT IDN SOLAR TECH NUSA120H-455M reaches 46.39 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PT IDN SOLAR TECH NUSA120H-455M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PT IDN SOLAR TECH NUSA120H-455M 8 kW Residential Fit
Needs 18 modules (419 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CTM10455HC11-06.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PT IDN SOLAR TECH NUSA120H-455M by PT IDN SOLAR TECH grounded in CEC test data and NEC 690.7/690.8 limits.
Why is PT IDN SOLAR TECH NUSA120H-455M PTC wattage (426.8 W) lower than STC (455.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 426.8 W PTC (93.8% retention) across PT IDN SOLAR TECH NUSA120H-455M's 2.16 m2 aperture.
Who should skip PT IDN SOLAR TECH NUSA120H-455M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 PT IDN SOLAR TECH NUSA120H-455M panels (419 sq ft) leave unusable roof gaps vs. CertainTeed CTM10455HC11-06.
What is the 1,000 V commercial string limit for PT IDN SOLAR TECH NUSA120H-455M?
On 1,000 V commercial inverters at -10 C (45.26 V cold Voc), PT IDN SOLAR TECH NUSA120H-455M fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)