Prism Solar Technologies Inc BN60-333BSTC — CEC Solar Module Specifications

Manufacturer: Prism Solar Technologies Inc Registry: CEC Verified Engineering Specification

Prism Solar Technologies Inc BN60-333BSTC is a 295.0 W STC (274.1 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 17.85% efficiency, 40.11 V Voc at 25 C, and 44.0 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
295.0 W
PTC Wattage
274.1 W
Voc @ 25C
40.11 V
Efficiency
17.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Prism Solar Technologies Inc BN60-333BSTC Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Prism Solar Technologies Inc BN60-333BSTC (Mono-c-Si) residential solar systems.

Prism Solar Technologies Inc BN60-333BSTC delivers 178.5 W/m2 (2.06 percentage points below 19.91% CEC median) and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (498 sq ft). At -4 F (-20 C), string voltage climbs to 45.11 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with Auxin Solar AXN6M610B295 (295.0 W).

Where Does Prism Solar Technologies Inc BN60-333BSTC Fall Across Listed CEC Models?

Comparison of Prism Solar Technologies Inc BN60-333BSTC (295.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Prism Solar Technologies Inc BN60-333BSTC (295.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPrism Solar Techno: 295.0 W

What Dataset Percentiles Define Prism Solar Technologies Inc BN60-333BSTC?

Relative ranking of Prism Solar Technologies Inc BN60-333BSTC across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency.

Prism Solar Technologies Inc BN60-333BSTC Engineering BenchmarksPercentile comparison of Prism Solar Technologies Inc BN60-333BSTC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage295.0 WPTC/STC Retention92.9%Module Efficiency17.85%

What Do the Dataset Ranks Show for Prism Solar Technologies Inc BN60-333BSTC?

Summary of Prism Solar Technologies Inc BN60-333BSTC output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.

Rank #16,890 / 21,677

295.0 W STC · Higher Than 20.4%

295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,310

17.85% Aperture Efficiency

Power density 178.5 W/m2 (2.06 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.0 V at -10 C (572.0 V string) and 45.11 V at -20 C (13 max).

8 kW Reference Array

28 Panels = 8,260 W STC

Occupies 46.3 m2 (498 sq ft) producing 7,675 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.11 * (1 + (-0.277/100) * (-10 - 25)) = 44.0 V | OCPD = 1.56 * 9.77 = 15.24 A

Inputs from CEC Modules.csv for Prism Solar Technologies Inc BN60-333BSTC: Voc=40.11 V, beta_Voc=-0.277%/C, Isc=9.77 A, STC=295.0 W, Area=1.653 m2.

Result: 13 panels max on 600 V (572.0 V); 28 panels for 8 kW (498 sq ft).

What Are the Published CEC Specifications for Prism Solar Technologies Inc BN60-333BSTC?

Complete CEC test sheet for Prism Solar Technologies Inc BN60-333BSTC including Isc (9.77 A), Voc (40.11 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Prism Solar Technologies Inc BN60-333BSTC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 295.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 274.1 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.11 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.24 V / 9.15 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.277 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.85% (1.653 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Bifacial glass-glass

How Many Prism Solar Technologies Inc BN60-333BSTC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Prism Solar Technologies Inc BN60-333BSTC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 21 6.2 kW 374 sq ft $1,552 $2,624
8 kW Class 28 8.26 kW 498 sq ft $2,067 $3,496
10 kW Class 34 10.03 kW 605 sq ft $2,510 $4,245

How Many Prism Solar Technologies Inc BN60-333BSTC Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Prism Solar Technologies Inc BN60-333BSTC (40.11 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.11V and beta_Voc=-0.277%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.11 V 13 panels 586.4 V 22 panels
-10 C (14 F) 44.0 V 13 panels 572.0 V 22 panels
0 C (32 F) 42.89 V 13 panels 557.6 V 23 panels
25 C (77 F STC) 40.11 V 14 panels 561.5 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Prism Solar Technologies Inc BN60-333BSTC?

Four comparable CEC modules such as Auxin Solar AXN6M610B295 (295.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M610B295
Auxin Solar
295.0 W Tie (0 W) 40.11 V 17.85% 92.9%
GCL System Integration Technology Co Ltd GCL-M6/60295
GCL System Integration Technology Co Ltd
295.0 W Tie (0 W) 39.3 V 18.1% 90.2%
CSI Solar Co Ltd CS3K-295MS
CSI Solar Co Ltd
295.0 W Tie (0 W) 39.1 V 18.4% 93.0%
CertainTeed CT290M10-02
CertainTeed
290.0 W -5.0 W 39.77 V 17.83% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Prism Solar Technologies Inc BN60-333BSTC?

Evaluate Prism Solar Technologies Inc BN60-333BSTC (295.0 W STC, 40.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Prism Solar Technologies Inc BN60-333BSTC reaches 45.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 28 panels for an 8 kW build require 498 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (498 sq ft).
  • 2026 tax credit baseline: cash residential installs of Prism Solar Technologies Inc BN60-333BSTC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Prism Solar Technologies Inc BN60-333BSTC 8 kW Residential Fit

Needs 28 modules (498 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610B295.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 274.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Prism Solar Technologies Inc BN60-333BSTC by Prism Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many Prism Solar Technologies Inc BN60-333BSTC panels fit on a 600 V winter solar string?

At -10 C (14 F), Prism Solar Technologies Inc BN60-333BSTC cold Voc rises from 40.11 V to 44.0 V (beta_Voc -0.277%/C), capping a 600 V string at 13 panels (572.0 V).

How much roof area does an 8 kW array of Prism Solar Technologies Inc BN60-333BSTC need?

An 8 kW DC system uses 28 Prism Solar Technologies Inc BN60-333BSTC modules (8,260 W STC / 7,675 W PTC), covering roughly 498 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does Prism Solar Technologies Inc BN60-333BSTC compare against Auxin Solar AXN6M610B295?

Prism Solar Technologies Inc BN60-333BSTC outputs 295.0 W STC (40.11 V Voc, rank #16,890 of 21,677), while Auxin Solar AXN6M610B295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.