Skip to main content
WireAndSun
Calculators
CEC PV Module

Prism Solar Technologies Inc PST-450W-M60H-M10 — CEC Solar Module Specifications

Manufacturer: Prism Solar Technologies Inc Registry: CEC Verified Engineering Specification

Prism Solar Technologies Inc PST-450W-M60H-M10 is a 450.0 W STC (421.7 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.03% efficiency, 41.18 V Voc at 25 C, and 45.59 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
450.0 W
PTC Wattage
421.7 W
Voc @ 25C
41.18 V
Efficiency
21.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Prism Solar Technologies Inc PST-450W-M60H-M10 Compare Against Peer CEC Listings?

How Prism Solar Technologies Inc Prism Solar Technologies Inc PST-450W-M60H-M10 handles rooftop heat (421.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Prism Solar Technologies Inc PST-450W-M60H-M10 exhibits 13.85 A short-circuit current, requiring a 21.61 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,679 of 21,677 (40.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.5 m2 for an 8 kW system (23 panels for 10 kW). Mid-range 41.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Prism Solar Technologies Inc PST-450W-M60H-M10 Fall Across Listed CEC Models?

Where Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPrism Solar Techno: 450.0 W

What Dataset Percentiles Define Prism Solar Technologies Inc PST-450W-M60H-M10?

Percentile placement of Prism Solar Technologies Inc PST-450W-M60H-M10 across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.

Prism Solar Technologies Inc PST-450W-M60H-M10 Engineering BenchmarksPercentile comparison of Prism Solar Technologies Inc PST-450W-M60H-M10 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage450.0 WPTC/STC Retention93.7%Module Efficiency21.03%

What Do the Dataset Ranks Show for Prism Solar Technologies Inc PST-450W-M60H-M10?

Four critical engineering numbers homeowners and solar installers check first when reviewing Prism Solar Technologies Inc PST-450W-M60H-M10 specifications.

Rank #5,679 / 21,677

Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,235

21.03% Aperture Efficiency

Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.59 V at -10 C (592.7 V string) and 46.85 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,100 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,591 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.18 * (1 + (-0.306/100) * (-10 - 25)) = 45.59 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for Prism Solar Technologies Inc PST-450W-M60H-M10: Voc=41.18 V, beta_Voc=-0.306%/C, Isc=13.85 A, STC=450.0 W, Area=2.14 m2.

Result: 13 panels max on 600 V (592.7 V); 18 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for Prism Solar Technologies Inc PST-450W-M60H-M10?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Prism Solar Technologies Inc PST-450W-M60H-M10.

Official California Energy Commission (NREL SAM) test parameters for Prism Solar Technologies Inc PST-450W-M60H-M10.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 450.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 421.7 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.18 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.91 V / 13.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.03% (2.14 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Prism Solar Technologies Inc PST-450W-M60H-M10 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.3 kW 322 sq ft $1,577 $2,666
8 kW Class 18 8.1 kW 415 sq ft $2,027 $3,428
10 kW Class 23 10.35 kW 530 sq ft $2,591 $4,380

How Many Prism Solar Technologies Inc PST-450W-M60H-M10 Modules Fit in a Cold-Weather String?

Maximum series module counts for Prism Solar Technologies Inc PST-450W-M60H-M10 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.18V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.85 V 12 panels 562.2 V 21 panels
-10 C (14 F) 45.59 V 13 panels 592.7 V 21 panels
0 C (32 F) 44.33 V 13 panels 576.3 V 22 panels
25 C (77 F STC) 41.18 V 14 panels 576.5 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Prism Solar Technologies Inc PST-450W-M60H-M10?

Alternative CEC solar modules from competing brands near Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W), including CertainTeed CTM10450HC11-06.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10450HC11-06
CertainTeed
450.0 W Tie (0 W) 41.18 V 20.83% 93.8%
Dehui Solar Power (Vietnam) CoLtd DH-M160B 455W
Dehui Solar Power (Vietnam) CoLtd
455.0 W +5.0 W 41.28 V 21.26% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M160W 455W
Dehui Solar Power (Vietnam) CoLtd
455.0 W +5.0 W 41.28 V 21.26% 92.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W +5.0 W 41.3 V 21.26% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Prism Solar Technologies Inc PST-450W-M60H-M10?

Evaluate Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W STC, 41.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Prism Solar Technologies Inc PST-450W-M60H-M10 reaches 46.85 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Prism Solar Technologies Inc PST-450W-M60H-M10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Prism Solar Technologies Inc PST-450W-M60H-M10 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CTM10450HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 421.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Prism Solar Technologies Inc PST-450W-M60H-M10 by Prism Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Prism Solar Technologies Inc PST-450W-M60H-M10 PTC wattage (421.7 W) lower than STC (450.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 421.7 W PTC (93.7% retention) across Prism Solar Technologies Inc PST-450W-M60H-M10's 2.14 m2 aperture.

Who should skip Prism Solar Technologies Inc PST-450W-M60H-M10 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Prism Solar Technologies Inc PST-450W-M60H-M10 panels (415 sq ft) leave unusable roof gaps vs. CertainTeed CTM10450HC11-06.

What is the 1,000 V commercial string limit for Prism Solar Technologies Inc PST-450W-M60H-M10?

On 1,000 V commercial inverters at -10 C (45.59 V cold Voc), Prism Solar Technologies Inc PST-450W-M60H-M10 fits up to 21 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.