Prism Solar Technologies Inc PST-450W-M60H-M10 is a 450.0 W STC (421.7 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.03% efficiency, 41.18 V Voc at 25 C, and 45.59 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 421.7 W
- Voc @ 25C
- 41.18 V
- Efficiency
- 21.03%
How Does Prism Solar Technologies Inc PST-450W-M60H-M10 Compare Against Peer CEC Listings?
How Prism Solar Technologies Inc Prism Solar Technologies Inc PST-450W-M60H-M10 handles rooftop heat (421.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Prism Solar Technologies Inc PST-450W-M60H-M10 exhibits 13.85 A short-circuit current, requiring a 21.61 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,679 of 21,677 (40.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.5 m2 for an 8 kW system (23 panels for 10 kW). Mid-range 41.18 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does Prism Solar Technologies Inc PST-450W-M60H-M10 Fall Across Listed CEC Models?
Where Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Prism Solar Technologies Inc PST-450W-M60H-M10?
Percentile placement of Prism Solar Technologies Inc PST-450W-M60H-M10 across power density (210.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Prism Solar Technologies Inc PST-450W-M60H-M10?
Four critical engineering numbers homeowners and solar installers check first when reviewing Prism Solar Technologies Inc PST-450W-M60H-M10 specifications.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.03% Aperture Efficiency
Power density 210.3 W/m2 (1.12 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.59 V at -10 C (592.7 V string) and 46.85 V at -20 C (12 max).
18 Panels = 8,100 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,591 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.18 * (1 + (-0.306/100) * (-10 - 25)) = 45.59 V | OCPD = 1.56 * 13.85 = 21.61 A
Inputs from CEC Modules.csv for Prism Solar Technologies Inc PST-450W-M60H-M10: Voc=41.18 V, beta_Voc=-0.306%/C, Isc=13.85 A, STC=450.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (592.7 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for Prism Solar Technologies Inc PST-450W-M60H-M10?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Prism Solar Technologies Inc PST-450W-M60H-M10.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 421.7 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.18 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.91 V / 13.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.306 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.03% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Prism Solar Technologies Inc PST-450W-M60H-M10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 322 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 415 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 530 sq ft | $2,591 | $4,380 |
How Many Prism Solar Technologies Inc PST-450W-M60H-M10 Modules Fit in a Cold-Weather String?
Maximum series module counts for Prism Solar Technologies Inc PST-450W-M60H-M10 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.85 V | 12 panels | 562.2 V | 21 panels |
| -10 C (14 F) | 45.59 V | 13 panels | 592.7 V | 21 panels |
| 0 C (32 F) | 44.33 V | 13 panels | 576.3 V | 22 panels |
| 25 C (77 F STC) | 41.18 V | 14 panels | 576.5 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Prism Solar Technologies Inc PST-450W-M60H-M10?
Alternative CEC solar modules from competing brands near Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W), including CertainTeed CTM10450HC11-06.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CTM10450HC11-06 CertainTeed |
450.0 W | Tie (0 W) | 41.18 V | 20.83% | 93.8% |
| Dehui Solar Power (Vietnam) CoLtd DH-M160B 455W Dehui Solar Power (Vietnam) CoLtd |
455.0 W | +5.0 W | 41.28 V | 21.26% | 92.7% |
| Dehui Solar Power (Vietnam) CoLtd DH-M160W 455W Dehui Solar Power (Vietnam) CoLtd |
455.0 W | +5.0 W | 41.28 V | 21.26% | 92.9% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
455.0 W | +5.0 W | 41.3 V | 21.26% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Prism Solar Technologies Inc PST-450W-M60H-M10?
Evaluate Prism Solar Technologies Inc PST-450W-M60H-M10 (450.0 W STC, 41.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Prism Solar Technologies Inc PST-450W-M60H-M10 reaches 46.85 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Prism Solar Technologies Inc PST-450W-M60H-M10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Prism Solar Technologies Inc PST-450W-M60H-M10 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CTM10450HC11-06.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 421.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Prism Solar Technologies Inc PST-450W-M60H-M10 by Prism Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Prism Solar Technologies Inc PST-450W-M60H-M10 PTC wattage (421.7 W) lower than STC (450.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 421.7 W PTC (93.7% retention) across Prism Solar Technologies Inc PST-450W-M60H-M10's 2.14 m2 aperture.
Who should skip Prism Solar Technologies Inc PST-450W-M60H-M10 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Prism Solar Technologies Inc PST-450W-M60H-M10 panels (415 sq ft) leave unusable roof gaps vs. CertainTeed CTM10450HC11-06.
What is the 1,000 V commercial string limit for Prism Solar Technologies Inc PST-450W-M60H-M10?
On 1,000 V commercial inverters at -10 C (45.59 V cold Voc), Prism Solar Technologies Inc PST-450W-M60H-M10 fits up to 21 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)