PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB is a 390.0 W STC (361.5 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.0% efficiency, 36.72 V Voc at 25 C, and 40.45 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 361.5 W
- Voc @ 25C
- 36.72 V
- Efficiency
- 20.0%
How Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB Compare Against Peer CEC Listings?
How PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB handles rooftop heat (361.5 W PTC), 8 kW sizing, and cold winter string voltage.
PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd builds the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). Compared against Aptos Solar Technology LLC DNA-108-BF10-390W (390.0 W), this model holds strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677). Lower 36.72 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.2 A overcurrent floor served by a 25 A breaker.
Where Does PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB Fall Across Listed CEC Models?
Where PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB?
Percentile placement of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB across power density (200.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB?
Four critical engineering numbers homeowners and solar installers check first when reviewing PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB specifications.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.0% Aperture Efficiency
Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.45 V at -10 C (566.3 V string) and 41.51 V at -20 C (14 max).
21 Panels = 8,190 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,592 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.72 * (1 + (-0.29/100) * (-10 - 25)) = 40.45 V | OCPD = 1.56 * 13.59 = 21.2 A
Inputs from CEC Modules.csv for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB: Voc=36.72 V, beta_Voc=-0.29%/C, Isc=13.59 A, STC=390.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (566.3 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 361.5 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.88 V / 12.64 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.29 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.0% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB (390.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 336 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 441 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 546 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd Series?
All closely matched PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd wattages and cosmetic trims sharing the PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-385HGB | 385.0 W | 356.7 W | 36.64 V | 30.76 V | 19.74% |
| PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB | 390.0 W | 361.5 W | 36.72 V | 30.88 V | 20.0% |
| PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-395HGB | 395.0 W | 366.2 W | 36.83 V | 31.04 V | 20.26% |
How Many PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB Modules Fit in a Cold-Weather String?
Maximum series module counts for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.51 V | 14 panels | 581.1 V | 24 panels |
| -10 C (14 F) | 40.45 V | 14 panels | 566.3 V | 24 panels |
| 0 C (32 F) | 39.38 V | 15 panels | 590.7 V | 25 panels |
| 25 C (77 F STC) | 36.72 V | 16 panels | 587.5 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB?
Alternative CEC solar modules from competing brands near PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB (390.0 W), including Aptos Solar Technology LLC DNA-108-BF10-390W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-BF10-390W Aptos Solar Technology LLC |
390.0 W | Tie (0 W) | 36.85 V | 20.21% | 93.2% |
| Dehui Solar Power (Vietnam) CoLtd DH-M154T 390W Dehui Solar Power (Vietnam) CoLtd |
390.0 W | Tie (0 W) | 36.85 V | 20.21% | 93.2% |
| ELITE Solar ET-M754BH390TB ELITE Solar |
390.0 W | Tie (0 W) | 36.85 V | 15.23% | 93.8% |
| ELITE Solar ET-M754BH390TW ELITE Solar |
390.0 W | Tie (0 W) | 36.85 V | 15.23% | 93.8% |
What Are the Design Limits and Best-Fit Uses for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB?
Evaluate PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB (390.0 W STC, 36.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB reaches 41.51 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-BF10-390W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 361.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB by PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB?
Multiplying PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB's 13.59 A short-circuit current by 1.56 equals 21.2 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.45 V cold Voc at 14 F and handles 13.59 A Isc; string inverters cap PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB at 14 panels on 600 V.
Is PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)