Manufacturer: Phono Solar Technology Co Ltd Registry: CEC Verified Engineering Specification

Phono Solar Technology Co Ltd PS270P-24/T is a 270.0 W STC (243.3 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.92% efficiency, 44.4 V Voc at 25 C, and 49.78 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
243.3 W
Voc @ 25C
44.4 V
Efficiency
13.92%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Phono Solar Technology Co Ltd PS270P-24/T Compare Against Peer CEC Listings?

Engineering position of Phono Solar Technology Co Ltd PS270P-24/T (270.0 W STC) vs. AXITEC AC-270P/156-72S across 1,407 CEC Multi-c-Si solar modules.

Ranking #18,572 across 21,677 CEC solar panels (below all-CEC median; higher than 12.9% of peers), Phono Solar Technology Co Ltd PS270P-24/T operates as a compact residential or specialty off-grid module sitting 8.8 W below the 278.8 W Multi-c-Si median. Mid-range 44.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With typical 90.1% PTC-to-STC thermal output (243.3 W real-world rating), 30 panels occupy 626 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Phono Solar Technology Co Ltd PS270P-24/T Fall Across Listed CEC Models?

Plots Phono Solar Technology Co Ltd PS270P-24/T at 270.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Phono Solar Technology Co Ltd PS270P-24/T (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPhono Solar Techno: 270.0 W

What Dataset Percentiles Define Phono Solar Technology Co Ltd PS270P-24/T?

Benchmarks Phono Solar Technology Co Ltd PS270P-24/T on STC wattage, thermal PTC/STC retention, and 13.92 aperture conversion efficiency against CEC peers.

Phono Solar Technology Co Ltd PS270P-24/T Engineering BenchmarksPercentile comparison of Phono Solar Technology Co Ltd PS270P-24/T wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention90.1%Module Efficiency13.92%

What Do the Dataset Ranks Show for Phono Solar Technology Co Ltd PS270P-24/T?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Phono Solar Technology Co Ltd PS270P-24/T by Phono Solar Technology Co Ltd.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,945

13.92% Aperture Efficiency

Power density 139.2 W/m2 (5.99 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.78 V at -10 C (597.4 V string) and 51.31 V at -20 C (11 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 58.2 m2 (626 sq ft) producing 7,299 W PTC; NEC 690.8 OCPD floor is 12.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.4 * (1 + (-0.346/100) * (-10 - 25)) = 49.78 V | OCPD = 1.56 * 8.2 = 12.79 A

Inputs from CEC Modules.csv for Phono Solar Technology Co Ltd PS270P-24/T: Voc=44.4 V, beta_Voc=-0.346%/C, Isc=8.2 A, STC=270.0 W, Area=1.94 m2.

Result: 12 panels max on 600 V (597.4 V); 30 panels for 8 kW (626 sq ft).

What Are the Published CEC Specifications for Phono Solar Technology Co Ltd PS270P-24/T?

Laboratory test ratings recorded for Phono Solar Technology Co Ltd PS270P-24/T (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Phono Solar Technology Co Ltd PS270P-24/T.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 243.3 W (90.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.5 V / 7.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.346 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.92% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Phono Solar Technology Co Ltd PS270P-24/T Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (626 sq ft at 8 kW), and estimated Year-1 electric bill offset for Phono Solar Technology Co Ltd PS270P-24/T.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 480 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 626 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 794 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Phono Solar Technology Co Ltd Series?

Sibling wattage bins and frame colors grouped with Phono Solar Technology Co Ltd PS270P-24/T under Phono Solar Technology Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Phono Solar Technology Co Ltd PS270P-24/T wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Phono Solar Technology Co Ltd PS260P-24/T 260.0 W 234.1 W 44.0 V 35.2 V 13.4%
Phono Solar Technology Co Ltd PS270P-24/T 270.0 W 243.3 W 44.4 V 35.5 V 13.92%

How Many Phono Solar Technology Co Ltd PS270P-24/T Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Phono Solar Technology Co Ltd PS270P-24/T (beta_Voc -0.346%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=44.4V and beta_Voc=-0.346%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.31 V 11 panels 564.4 V 19 panels
-10 C (14 F) 49.78 V 12 panels 597.4 V 20 panels
0 C (32 F) 48.24 V 12 panels 578.9 V 20 panels
25 C (77 F STC) 44.4 V 13 panels 577.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Phono Solar Technology Co Ltd PS270P-24/T?

Closest cross-brand CEC competitors to Phono Solar Technology Co Ltd PS270P-24/T matched near 270.0 W STC and 44.4 V Voc, led by AXITEC AC-270P/156-72S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-270P/156-72S
AXITEC
270.0 W Tie (0 W) 44.18 V 13.94% 89.9%
Advance Power API-M270
Advance Power
270.0 W Tie (0 W) 44.64 V 13.84% 89.0%
Auxin Solar AXN6M612T270
Auxin Solar
270.0 W Tie (0 W) 44.64 V 13.84% 89.0%
Centrosolar America DP72 270
Centrosolar America
270.0 W Tie (0 W) 43.85 V 13.89% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Phono Solar Technology Co Ltd PS270P-24/T?

Evaluate Phono Solar Technology Co Ltd PS270P-24/T (270.0 W STC, 44.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Phono Solar Technology Co Ltd PS270P-24/T reaches 51.31 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 626 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (626 sq ft).
  • 2026 tax credit baseline: cash residential installs of Phono Solar Technology Co Ltd PS270P-24/T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Phono Solar Technology Co Ltd PS270P-24/T 8 kW Residential Fit

Needs 30 modules (626 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-270P/156-72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 243.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Phono Solar Technology Co Ltd PS270P-24/T by Phono Solar Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Phono Solar Technology Co Ltd PS270P-24/T panels fit on a 600 V winter solar string?

At -10 C (14 F), Phono Solar Technology Co Ltd PS270P-24/T cold Voc rises from 44.4 V to 49.78 V (beta_Voc -0.346%/C), capping a 600 V string at 12 panels (597.4 V).

How much roof area does an 8 kW array of Phono Solar Technology Co Ltd PS270P-24/T need?

An 8 kW DC system uses 30 Phono Solar Technology Co Ltd PS270P-24/T modules (8,100 W STC / 7,299 W PTC), covering roughly 626 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Phono Solar Technology Co Ltd PS270P-24/T compare against AXITEC AC-270P/156-72S?

Phono Solar Technology Co Ltd PS270P-24/T outputs 270.0 W STC (44.4 V Voc, rank #18,572 of 21,677), while AXITEC AC-270P/156-72S delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls