Philadelphia Solar PS-P54-220 is a 220.0 W STC (195.1 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 14.86% efficiency, 33.64 V Voc at 25 C, and 37.6 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 195.1 W
- Voc @ 25C
- 33.64 V
- Efficiency
- 14.86%
How Does Philadelphia Solar PS-P54-220 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Philadelphia Solar PS-P54-220 (Multi-c-Si) residential solar systems.
Homeowners evaluating Philadelphia Solar PS-P54-220 need 28 panels for 6 kW or 37 panels (589 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (589 sq ft). Under NEC 690.7(A), beta_Voc (-0.336%/C) pushes open-circuit voltage to 37.6 V at 14 F and 38.73 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Philadelphia Solar PS-P54-220 Fall Across Listed CEC Models?
Comparison of Philadelphia Solar PS-P54-220 (220.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define Philadelphia Solar PS-P54-220?
Relative ranking of Philadelphia Solar PS-P54-220 across nameplate watts, 88.7% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for Philadelphia Solar PS-P54-220?
Summary of Philadelphia Solar PS-P54-220 output rank, 8 kW array size (37 panels), efficiency rating, and 600 V string limit.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.86% Aperture Efficiency
Power density 148.6 W/m2 (5.05 percentage points below 19.91% CEC median). PTC/STC ratio: 88.7% (rank #21,046).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.6 V at -10 C (564.0 V string) and 38.73 V at -20 C (15 max).
37 Panels = 8,140 W STC
Occupies 54.8 m2 (589 sq ft) producing 7,219 W PTC; NEC 690.8 OCPD floor is 13.09 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.64 * (1 + (-0.336/100) * (-10 - 25)) = 37.6 V | OCPD = 1.56 * 8.39 = 13.09 A
Inputs from CEC Modules.csv for Philadelphia Solar PS-P54-220: Voc=33.64 V, beta_Voc=-0.336%/C, Isc=8.39 A, STC=220.0 W, Area=1.48 m2.
Result: 15 panels max on 600 V (564.0 V); 37 panels for 8 kW (589 sq ft).
What Are the Published CEC Specifications for Philadelphia Solar PS-P54-220?
Complete CEC test sheet for Philadelphia Solar PS-P54-220 including Isc (8.39 A), Voc (33.64 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 195.1 W (88.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.64 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.39 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.97 V / 7.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.336 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.86% (1.48 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many Philadelphia Solar PS-P54-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Philadelphia Solar PS-P54-220.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 446 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 589 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 733 sq ft | $2,533 | $4,283 |
How Many Philadelphia Solar PS-P54-220 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Philadelphia Solar PS-P54-220 (33.64 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.73 V | 15 panels | 580.9 V | 25 panels |
| -10 C (14 F) | 37.6 V | 15 panels | 564.0 V | 26 panels |
| 0 C (32 F) | 36.47 V | 16 panels | 583.5 V | 27 panels |
| 25 C (77 F STC) | 33.64 V | 17 panels | 571.9 V | 29 panels |
Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-P54-220?
Four comparable CEC modules such as Gintung Energy ASEC-220G6M69 (220.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-220G6M69 Gintung Energy |
220.0 W | Tie (0 W) | 33.75 V | 15.02% | 89.6% |
| Gintung Energy GTEC-220G6M69 Gintung Energy |
220.0 W | Tie (0 W) | 33.75 V | 15.02% | 89.6% |
| Gintung Energy ASEC-220G6S69 Gintung Energy |
220.0 W | Tie (0 W) | 33.86 V | 15.02% | 89.8% |
| Gintung Energy GTEC-220G6S69 Gintung Energy |
220.0 W | Tie (0 W) | 33.86 V | 15.02% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-P54-220?
Evaluate Philadelphia Solar PS-P54-220 (220.0 W STC, 33.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-P54-220 reaches 38.73 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 589 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (589 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-P54-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Philadelphia Solar PS-P54-220 8 kW Residential Fit
Needs 37 modules (589 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Gintung Energy ASEC-220G6M69.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 195.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Philadelphia Solar PS-P54-220 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Philadelphia Solar PS-P54-220 PTC wattage (195.1 W) lower than STC (220.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 195.1 W PTC (88.7% retention) across Philadelphia Solar PS-P54-220's 1.48 m2 aperture.
Who should skip Philadelphia Solar PS-P54-220 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 37 Philadelphia Solar PS-P54-220 panels (589 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-220G6M69.
What is the 1,000 V commercial string limit for Philadelphia Solar PS-P54-220?
On 1,000 V commercial inverters at -10 C (37.6 V cold Voc), Philadelphia Solar PS-P54-220 fits up to 26 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Philadelphia Solar PS-P54-220.