Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy GTEC-220G6S69 — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy GTEC-220G6S69 is a 220.0 W STC (197.5 W PTC) Mono-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 15.02% efficiency, 33.86 V Voc at 25 C, and 37.89 V cold Voc at -10 C (15 panels max per 600 V string).

STC Wattage
220.0 W
PTC Wattage
197.5 W
Voc @ 25C
33.86 V
Efficiency
15.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy GTEC-220G6S69 Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy GTEC-220G6S69: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Measured at 220.0 W STC and 197.5 W PTC, Gintung Energy GTEC-220G6S69 sits -165.0 W vs all-CEC median (below all-CEC median; higher than 3.8% of peers) among 21,677 listed modules. Power density reaches 150.2 W/m2 (4.89 percentage points below 19.91% CEC median). Lower 33.86 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 26 panels in series. Alternative peer Alps Technology ATI-M660-220 rates 220.0 W.

Where Does Gintung Energy GTEC-220G6S69 Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy GTEC-220G6S69 (220.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy GTEC-220G6S69 (220.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy GTE: 220.0 W

What Dataset Percentiles Define Gintung Energy GTEC-220G6S69?

Dataset percentiles tracking Gintung Energy GTEC-220G6S69 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Gintung Energy GTEC-220G6S69 Engineering BenchmarksPercentile comparison of Gintung Energy GTEC-220G6S69 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage220.0 WPTC/STC Retention89.8%Module Efficiency15.02%

What Do the Dataset Ranks Show for Gintung Energy GTEC-220G6S69?

Benchmark highlights for Gintung Energy GTEC-220G6S69 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #20,759 / 21,677

220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,685

15.02% Aperture Efficiency

Power density 150.2 W/m2 (4.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).

NEC 690.7 Limit

15 Panels Max @ -10 C (600 V)

Cold Voc reaches 37.89 V at -10 C (568.4 V string) and 39.04 V at -20 C (15 max).

8 kW Reference Array

37 Panels = 8,140 W STC

Occupies 54.2 m2 (583 sq ft) producing 7,308 W PTC; NEC 690.8 OCPD floor is 13.43 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.86 * (1 + (-0.34/100) * (-10 - 25)) = 37.89 V | OCPD = 1.56 * 8.61 = 13.43 A

Inputs from CEC Modules.csv for Gintung Energy GTEC-220G6S69: Voc=33.86 V, beta_Voc=-0.34%/C, Isc=8.61 A, STC=220.0 W, Area=1.465 m2.

Result: 15 panels max on 600 V (568.4 V); 37 panels for 8 kW (583 sq ft).

What Are the Published CEC Specifications for Gintung Energy GTEC-220G6S69?

Official CEC datasheet figures for Gintung Energy GTEC-220G6S69 (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy GTEC-220G6S69.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 220.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 197.5 W (89.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.86 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.61 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 26.67 V / 8.25 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.02% (1.465 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy GTEC-220G6S69 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy GTEC-220G6S69 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.16 kW 442 sq ft $1,542 $2,607
8 kW Class 37 8.14 kW 583 sq ft $2,037 $3,445
10 kW Class 46 10.12 kW 725 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy GTEC-220G6S69 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Gintung Energy GTEC-220G6S69 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy GTEC-215G6S69 215.0 W 192.9 W 33.77 V 26.58 V 14.68%
Gintung Energy GTEC-220G6S69 220.0 W 197.5 W 33.86 V 26.67 V 15.02%

How Many Gintung Energy GTEC-220G6S69 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy GTEC-220G6S69 (37.89 V at 14 F).

Computed from Voc=33.86V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 39.04 V 15 panels 585.6 V 25 panels
-10 C (14 F) 37.89 V 15 panels 568.4 V 26 panels
0 C (32 F) 36.74 V 16 panels 587.8 V 27 panels
25 C (77 F STC) 33.86 V 17 panels 575.6 V 29 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-220G6S69?

Competing CEC solar panels closest to Gintung Energy GTEC-220G6S69 in nameplate wattage and Voc, starting with Alps Technology ATI-M660-220.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Alps Technology ATI-M660-220
Alps Technology
220.0 W Tie (0 W) 36.06 V 13.67% 86.0%
Anji Technology AJP-M660-220
Anji Technology
220.0 W Tie (0 W) 36.06 V 13.55% 86.0%
Centrosolar America DP60 220
Centrosolar America
220.0 W Tie (0 W) 36.26 V 13.42% 89.8%
Anhui Rinengzhongtian Semiconductor Development QJM220-60
Anhui Rinengzhongtian Semiconductor Development
220.0 W Tie (0 W) 36.29 V 13.52% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-220G6S69?

Evaluate Gintung Energy GTEC-220G6S69 (220.0 W STC, 33.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-220G6S69 reaches 39.04 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 37 panels for an 8 kW build require 583 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (583 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-220G6S69 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy GTEC-220G6S69 8 kW Residential Fit

Needs 37 modules (583 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Alps Technology ATI-M660-220.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 197.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy GTEC-220G6S69 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Gintung Energy GTEC-220G6S69 panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy GTEC-220G6S69 cold Voc rises from 33.86 V to 37.89 V (beta_Voc -0.34%/C), capping a 600 V string at 15 panels (568.4 V).

How much roof area does an 8 kW array of Gintung Energy GTEC-220G6S69 need?

An 8 kW DC system uses 37 Gintung Energy GTEC-220G6S69 modules (8,140 W STC / 7,308 W PTC), covering roughly 583 sq ft and saving ~$2,037/yr at 18.54 c/kWh.

How does Gintung Energy GTEC-220G6S69 compare against Alps Technology ATI-M660-220?

Gintung Energy GTEC-220G6S69 outputs 220.0 W STC (33.86 V Voc, rank #20,759 of 21,677), while Alps Technology ATI-M660-220 delivers 220.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.