Gintung Energy GTEC-220G6M69 is a 220.0 W STC (197.1 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 15.02% efficiency, 33.75 V Voc at 25 C, and 37.65 V cold Voc at -10 C (15 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 197.1 W
- Voc @ 25C
- 33.75 V
- Efficiency
- 15.02%
How Does Gintung Energy GTEC-220G6M69 Compare Against Peer CEC Listings?
How Gintung Energy Gintung Energy GTEC-220G6M69 handles rooftop heat (197.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Gintung Energy GTEC-220G6M69 exhibits 8.75 A short-circuit current, requiring a 13.65 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,759 of 21,677 (58.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 54.2 m2 for an 8 kW system (46 panels for 10 kW). Lower 33.75 V string voltage fits 15 panels in series at 14 F and pairs easily with microinverters.
Where Does Gintung Energy GTEC-220G6M69 Fall Across Listed CEC Models?
Where Gintung Energy GTEC-220G6M69 (220.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy GTEC-220G6M69?
Percentile placement of Gintung Energy GTEC-220G6M69 across power density (150.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Gintung Energy GTEC-220G6M69?
Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy GTEC-220G6M69 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.02% Aperture Efficiency
Power density 150.2 W/m2 (4.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).
15 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.65 V at -10 C (564.8 V string) and 38.76 V at -20 C (15 max).
37 Panels = 8,140 W STC
Occupies 54.2 m2 (583 sq ft) producing 7,293 W PTC; NEC 690.8 OCPD floor is 13.65 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.75 * (1 + (-0.33/100) * (-10 - 25)) = 37.65 V | OCPD = 1.56 * 8.75 = 13.65 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-220G6M69: Voc=33.75 V, beta_Voc=-0.33%/C, Isc=8.75 A, STC=220.0 W, Area=1.465 m2.
Result: 15 panels max on 600 V (564.8 V); 37 panels for 8 kW (583 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-220G6M69?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy GTEC-220G6M69.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 197.1 W (89.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.75 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.71 V / 8.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.02% (1.465 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-220G6M69 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy GTEC-220G6M69 (220.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 442 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 583 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 725 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy GTEC-220G6M69 architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-215G6M69 | 215.0 W | 192.5 W | 33.69 V | 26.61 V | 14.68% |
| Gintung Energy GTEC-220G6M69 | 220.0 W | 197.1 W | 33.75 V | 26.71 V | 15.02% |
How Many Gintung Energy GTEC-220G6M69 Modules Fit in a Cold-Weather String?
Maximum series module counts for Gintung Energy GTEC-220G6M69 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.76 V | 15 panels | 581.4 V | 25 panels |
| -10 C (14 F) | 37.65 V | 15 panels | 564.8 V | 26 panels |
| 0 C (32 F) | 36.53 V | 16 panels | 584.5 V | 27 panels |
| 25 C (77 F STC) | 33.75 V | 17 panels | 573.8 V | 29 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-220G6M69?
Alternative CEC solar modules from competing brands near Gintung Energy GTEC-220G6M69 (220.0 W), including Alps Technology ATI-M660-220. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Alps Technology ATI-M660-220 Alps Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| Anji Technology AJP-M660-220 Anji Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.55% | 86.0% |
| Centrosolar America DP60 220 Centrosolar America |
220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| Anhui Rinengzhongtian Semiconductor Development QJM220-60 Anhui Rinengzhongtian Semiconductor Development |
220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-220G6M69?
Evaluate Gintung Energy GTEC-220G6M69 (220.0 W STC, 33.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-220G6M69 reaches 38.76 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 583 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (583 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-220G6M69 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-220G6M69 8 kW Residential Fit
Needs 37 modules (583 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 15 panels (-10 C) or 15 panels (-20 C), or compare Alps Technology ATI-M660-220.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 197.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-220G6M69 by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Gintung Energy GTEC-220G6M69 PTC wattage (197.1 W) lower than STC (220.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 197.1 W PTC (89.6% retention) across Gintung Energy GTEC-220G6M69's 1.465 m2 aperture.
Who should skip Gintung Energy GTEC-220G6M69 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 37 Gintung Energy GTEC-220G6M69 panels (583 sq ft) leave unusable roof gaps vs. Alps Technology ATI-M660-220.
What is the 1,000 V commercial string limit for Gintung Energy GTEC-220G6M69?
On 1,000 V commercial inverters at -10 C (37.65 V cold Voc), Gintung Energy GTEC-220G6M69 fits up to 26 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy GTEC-220G6M69.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)