Philadelphia Solar PS-M60(BF)-295 is a 295.0 W STC (270.7 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.21% efficiency, 39.6 V Voc at 25 C, and 43.34 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 270.7 W
- Voc @ 25C
- 39.6 V
- Efficiency
- 18.21%
How Does Philadelphia Solar PS-M60(BF)-295 Compare Against Peer CEC Listings?
How Philadelphia Solar Philadelphia Solar PS-M60(BF)-295 handles rooftop heat (270.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Philadelphia Solar PS-M60(BF)-295 exhibits 9.83 A short-circuit current, requiring a 15.33 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #16,890 of 21,677 (115.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 45.4 m2 for an 8 kW system (34 panels for 10 kW). Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does Philadelphia Solar PS-M60(BF)-295 Fall Across Listed CEC Models?
Where Philadelphia Solar PS-M60(BF)-295 (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Philadelphia Solar PS-M60(BF)-295?
Percentile placement of Philadelphia Solar PS-M60(BF)-295 across power density (182.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Philadelphia Solar PS-M60(BF)-295?
Four critical engineering numbers homeowners and solar installers check first when reviewing Philadelphia Solar PS-M60(BF)-295 specifications.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.21% Aperture Efficiency
Power density 182.1 W/m2 (1.70 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.34 V at -10 C (563.4 V string) and 44.41 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,580 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.6 * (1 + (-0.27/100) * (-10 - 25)) = 43.34 V | OCPD = 1.56 * 9.83 = 15.33 A
Inputs from CEC Modules.csv for Philadelphia Solar PS-M60(BF)-295: Voc=39.6 V, beta_Voc=-0.27%/C, Isc=9.83 A, STC=295.0 W, Area=1.62 m2.
Result: 13 panels max on 600 V (563.4 V); 28 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for Philadelphia Solar PS-M60(BF)-295?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Philadelphia Solar PS-M60(BF)-295.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 270.7 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.74 V / 9.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.27 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.21% (1.62 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Philadelphia Solar PS-M60(BF)-295 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Philadelphia Solar PS-M60(BF)-295 (295.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 366 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 488 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 593 sq ft | $2,510 | $4,245 |
How Many Philadelphia Solar PS-M60(BF)-295 Modules Fit in a Cold-Weather String?
Maximum series module counts for Philadelphia Solar PS-M60(BF)-295 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.41 V | 13 panels | 577.3 V | 22 panels |
| -10 C (14 F) | 43.34 V | 13 panels | 563.4 V | 23 panels |
| 0 C (32 F) | 42.27 V | 14 panels | 591.8 V | 23 panels |
| 25 C (77 F STC) | 39.6 V | 15 panels | 594.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Philadelphia Solar PS-M60(BF)-295?
Alternative CEC solar modules from competing brands near Philadelphia Solar PS-M60(BF)-295 (295.0 W), including Auxin Solar AXN6M610B295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610B295 Auxin Solar |
295.0 W | Tie (0 W) | 40.11 V | 17.85% | 92.9% |
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| CSI Solar Co Ltd CS3K-295MS CSI Solar Co Ltd |
295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | -5.0 W | 39.7 V | 17.68% | 90.9% |
What Are the Design Limits and Best-Fit Uses for Philadelphia Solar PS-M60(BF)-295?
Evaluate Philadelphia Solar PS-M60(BF)-295 (295.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Philadelphia Solar PS-M60(BF)-295 reaches 44.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of Philadelphia Solar PS-M60(BF)-295 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Philadelphia Solar PS-M60(BF)-295 8 kW Residential Fit
Needs 28 modules (488 sq ft) with a 20 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610B295.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 270.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Philadelphia Solar PS-M60(BF)-295 by Philadelphia Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Philadelphia Solar PS-M60(BF)-295 PTC wattage (270.7 W) lower than STC (295.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 270.7 W PTC (91.8% retention) across Philadelphia Solar PS-M60(BF)-295's 1.62 m2 aperture.
Who should skip Philadelphia Solar PS-M60(BF)-295 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Philadelphia Solar PS-M60(BF)-295 panels (488 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M610B295.
What is the 1,000 V commercial string limit for Philadelphia Solar PS-M60(BF)-295?
On 1,000 V commercial inverters at -10 C (43.34 V cold Voc), Philadelphia Solar PS-M60(BF)-295 fits up to 23 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)