Perfect Source Technology PST 188 3GP48 — CEC Solar Module Specifications

Manufacturer: Perfect Source Technology Registry: CEC Verified Engineering Specification

Perfect Source Technology PST 188 3GP48 is a 188.0 W STC (167.8 W PTC) Multi-c-Si solar module ranking #21,184 of 21,677 CEC listings (below all-CEC median; higher than 2.3% of peers). It delivers 14.02% efficiency, 30.0 V Voc at 25 C, and 33.57 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
188.0 W
PTC Wattage
167.8 W
Voc @ 25C
30.0 V
Efficiency
14.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Perfect Source Technology PST 188 3GP48 Compare Against Peer CEC Listings?

How Perfect Source Technology Perfect Source Technology PST 188 3GP48 handles rooftop heat (167.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Perfect Source Technology PST 188 3GP48 exhibits 8.21 A short-circuit current, requiring a 12.81 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,184 of 21,677 (90.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.7 m2 for an 8 kW system (54 panels for 10 kW). Lower 30.0 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters.

Where Does Perfect Source Technology PST 188 3GP48 Fall Across Listed CEC Models?

Where Perfect Source Technology PST 188 3GP48 (188.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Perfect Source Technology PST 188 3GP48 (188.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPerfect Source Tec: 188.0 W

What Dataset Percentiles Define Perfect Source Technology PST 188 3GP48?

Percentile placement of Perfect Source Technology PST 188 3GP48 across power density (140.2 W/m2), thermal retention, and nameplate STC wattage.

Perfect Source Technology PST 188 3GP48 Engineering BenchmarksPercentile comparison of Perfect Source Technology PST 188 3GP48 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage188.0 WPTC/STC Retention89.3%Module Efficiency14.02%

What Do the Dataset Ranks Show for Perfect Source Technology PST 188 3GP48?

Four critical engineering numbers homeowners and solar installers check first when reviewing Perfect Source Technology PST 188 3GP48 specifications.

Rank #21,184 / 21,677

188.0 W STC · Higher Than 2.3%

188.0 W STC (-197.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,896

14.02% Aperture Efficiency

Power density 140.2 W/m2 (5.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.57 V at -10 C (570.7 V string) and 34.59 V at -20 C (17 max).

8 kW Reference Array

43 Panels = 8,084 W STC

Occupies 57.7 m2 (621 sq ft) producing 7,215 W PTC; NEC 690.8 OCPD floor is 12.81 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 30.0 * (1 + (-0.34/100) * (-10 - 25)) = 33.57 V | OCPD = 1.56 * 8.21 = 12.81 A

Inputs from CEC Modules.csv for Perfect Source Technology PST 188 3GP48: Voc=30.0 V, beta_Voc=-0.34%/C, Isc=8.21 A, STC=188.0 W, Area=1.341 m2.

Result: 17 panels max on 600 V (570.7 V); 43 panels for 8 kW (621 sq ft).

What Are the Published CEC Specifications for Perfect Source Technology PST 188 3GP48?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Perfect Source Technology PST 188 3GP48.

Official California Energy Commission (NREL SAM) test parameters for Perfect Source Technology PST 188 3GP48.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 188.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 167.8 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 30.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.21 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 24.58 V / 7.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.02% (1.341 m2) Array roof footprint density
Cell Count & Technology 48 cells (Multi-c-Si) Monofacial backsheet

How Many Perfect Source Technology PST 188 3GP48 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Perfect Source Technology PST 188 3GP48 (188.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 32 6.02 kW 462 sq ft $1,507 $2,548
8 kW Class 43 8.08 kW 621 sq ft $2,022 $3,420
10 kW Class 54 10.15 kW 779 sq ft $2,540 $4,296

Which Sibling Wattage & Trim Variants Belong to This Perfect Source Technology Series?

All closely matched Perfect Source Technology wattages and cosmetic trims sharing the Perfect Source Technology PST 188 3GP48 architecture.

Sibling CEC listings grouped into the Perfect Source Technology PST 188 3GP48 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Perfect Source Technology PST 176 3GP48 176.0 W 156.8 W 29.33 V 24.0 V 13.12%
Perfect Source Technology PST 188 3GP48 188.0 W 167.8 W 30.0 V 24.58 V 14.02%

How Many Perfect Source Technology PST 188 3GP48 Modules Fit in a Cold-Weather String?

Maximum series module counts for Perfect Source Technology PST 188 3GP48 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=30.0V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.59 V 17 panels 588.0 V 28 panels
-10 C (14 F) 33.57 V 17 panels 570.7 V 29 panels
0 C (32 F) 32.55 V 18 panels 585.9 V 30 panels
25 C (77 F STC) 30.0 V 20 panels 600.0 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Perfect Source Technology PST 188 3GP48?

Alternative CEC solar modules from competing brands near Perfect Source Technology PST 188 3GP48 (188.0 W), including Lightway Green New Energy LW190(23)P1310x990.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Lightway Green New Energy LW190(23)P1310x990
Lightway Green New Energy
190.0 W +2.0 W 30.0 V 14.8% 89.6%
Lightway Green New Energy LW185(23)P1310x990
Lightway Green New Energy
185.0 W -3.0 W 30.0 V 14.41% 89.6%
APOS Energy AS185
APOS Energy
185.0 W -3.0 W 29.78 V 13.8% 89.6%
Mitsubishi Electric PV-UD190HA6
Mitsubishi Electric
190.0 W +2.0 W 30.5 V 13.74% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Perfect Source Technology PST 188 3GP48?

Evaluate Perfect Source Technology PST 188 3GP48 (188.0 W STC, 30.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Perfect Source Technology PST 188 3GP48 reaches 34.59 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 43 panels for an 8 kW build require 621 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 43 panels (621 sq ft).
  • 2026 tax credit baseline: cash residential installs of Perfect Source Technology PST 188 3GP48 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Perfect Source Technology PST 188 3GP48 8 kW Residential Fit

Needs 43 modules (621 sq ft) with a 15 A string OCPD, offsetting ~$2,022/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Lightway Green New Energy LW190(23)P1310x990.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 167.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Perfect Source Technology PST 188 3GP48 by Perfect Source Technology grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Perfect Source Technology PST 188 3GP48 PTC wattage (167.8 W) lower than STC (188.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 167.8 W PTC (89.3% retention) across Perfect Source Technology PST 188 3GP48's 1.341 m2 aperture.

Who should skip Perfect Source Technology PST 188 3GP48 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 43 Perfect Source Technology PST 188 3GP48 panels (621 sq ft) leave unusable roof gaps vs. Lightway Green New Energy LW190(23)P1310x990.

What is the 1,000 V commercial string limit for Perfect Source Technology PST 188 3GP48?

On 1,000 V commercial inverters at -10 C (33.57 V cold Voc), Perfect Source Technology PST 188 3GP48 fits up to 29 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.