Lightway Green New Energy LW190(23)P1310x990 is a 190.0 W STC (170.3 W PTC) Multi-c-Si solar module ranking #21,132 of 21,677 CEC listings (below all-CEC median; higher than 2.3% of peers). It delivers 14.8% efficiency, 30.0 V Voc at 25 C, and 33.78 V cold Voc at -10 C (17 panels max per 600 V string).
- STC Wattage
- 190.0 W
- PTC Wattage
- 170.3 W
- Voc @ 25C
- 30.0 V
- Efficiency
- 14.8%
How Does Lightway Green New Energy LW190(23)P1310x990 Compare Against Peer CEC Listings?
How Lightway Green New Energy Lightway Green New Energy LW190(23)P1310x990 handles rooftop heat (170.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Lightway Green New Energy LW190(23)P1310x990 exhibits 8.56 A short-circuit current, requiring a 13.35 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,132 of 21,677 (88.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 55.2 m2 for an 8 kW system (53 panels for 10 kW). Lower 30.0 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters.
Where Does Lightway Green New Energy LW190(23)P1310x990 Fall Across Listed CEC Models?
Where Lightway Green New Energy LW190(23)P1310x990 (190.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Lightway Green New Energy LW190(23)P1310x990?
Percentile placement of Lightway Green New Energy LW190(23)P1310x990 across power density (148.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Lightway Green New Energy LW190(23)P1310x990?
Four critical engineering numbers homeowners and solar installers check first when reviewing Lightway Green New Energy LW190(23)P1310x990 specifications.
190.0 W STC · Higher Than 2.3%
190.0 W STC (-195.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.8% Aperture Efficiency
Power density 148.0 W/m2 (5.11 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).
17 Panels Max @ -10 C (600 V)
Cold Voc reaches 33.78 V at -10 C (574.3 V string) and 34.86 V at -20 C (17 max).
43 Panels = 8,170 W STC
Occupies 55.2 m2 (594 sq ft) producing 7,323 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 30.0 * (1 + (-0.36/100) * (-10 - 25)) = 33.78 V | OCPD = 1.56 * 8.56 = 13.35 A
Inputs from CEC Modules.csv for Lightway Green New Energy LW190(23)P1310x990: Voc=30.0 V, beta_Voc=-0.36%/C, Isc=8.56 A, STC=190.0 W, Area=1.284 m2.
Result: 17 panels max on 600 V (574.3 V); 43 panels for 8 kW (594 sq ft).
What Are the Published CEC Specifications for Lightway Green New Energy LW190(23)P1310x990?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Lightway Green New Energy LW190(23)P1310x990.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 190.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 170.3 W (89.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 30.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 24.0 V / 7.92 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.8% (1.284 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Multi-c-Si) | Monofacial backsheet |
How Many Lightway Green New Energy LW190(23)P1310x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Lightway Green New Energy LW190(23)P1310x990 (190.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 32 | 6.08 kW | 442 sq ft | $1,522 | $2,573 |
| 8 kW Class | 43 | 8.17 kW | 594 sq ft | $2,045 | $3,458 |
| 10 kW Class | 53 | 10.07 kW | 733 sq ft | $2,520 | $4,262 |
How Many Lightway Green New Energy LW190(23)P1310x990 Modules Fit in a Cold-Weather String?
Maximum series module counts for Lightway Green New Energy LW190(23)P1310x990 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 34.86 V | 17 panels | 592.6 V | 28 panels |
| -10 C (14 F) | 33.78 V | 17 panels | 574.3 V | 29 panels |
| 0 C (32 F) | 32.7 V | 18 panels | 588.6 V | 30 panels |
| 25 C (77 F STC) | 30.0 V | 20 panels | 600.0 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW190(23)P1310x990?
Alternative CEC solar modules from competing brands near Lightway Green New Energy LW190(23)P1310x990 (190.0 W), including Mitsubishi Electric PV-UD190HA6.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Mitsubishi Electric PV-UD190HA6 Mitsubishi Electric |
190.0 W | Tie (0 W) | 30.5 V | 13.74% | 91.7% |
| Perfect Source Technology PST 188 3GP48 Perfect Source Technology |
188.0 W | -2.0 W | 30.0 V | 14.02% | 89.3% |
| Shanghai ST Solar STP195-48 Shanghai ST Solar |
195.0 W | +5.0 W | 30.0 V | 14.58% | 89.6% |
| Gintung Energy ASEC-195G6M68 Gintung Energy |
195.0 W | +5.0 W | 29.87 V | 14.95% | 89.5% |
What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW190(23)P1310x990?
Evaluate Lightway Green New Energy LW190(23)P1310x990 (190.0 W STC, 30.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW190(23)P1310x990 reaches 34.86 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 43 panels for an 8 kW build require 594 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 43 panels (594 sq ft).
- 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW190(23)P1310x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lightway Green New Energy LW190(23)P1310x990 8 kW Residential Fit
Needs 43 modules (594 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare Mitsubishi Electric PV-UD190HA6.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 170.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lightway Green New Energy LW190(23)P1310x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Lightway Green New Energy LW190(23)P1310x990 PTC wattage (170.3 W) lower than STC (190.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 170.3 W PTC (89.6% retention) across Lightway Green New Energy LW190(23)P1310x990's 1.284 m2 aperture.
Who should skip Lightway Green New Energy LW190(23)P1310x990 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 43 Lightway Green New Energy LW190(23)P1310x990 panels (594 sq ft) leave unusable roof gaps vs. Mitsubishi Electric PV-UD190HA6.
What is the 1,000 V commercial string limit for Lightway Green New Energy LW190(23)P1310x990?
On 1,000 V commercial inverters at -10 C (33.78 V cold Voc), Lightway Green New Energy LW190(23)P1310x990 fits up to 29 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)