Skip to main content
WireAndSun
Calculators
CEC PV Module

Mission Solar Energy LLC TXI10-400108BB — CEC Solar Module Specifications

Manufacturer: Mission Solar Energy LLC Registry: CEC Verified Engineering Specification

Mission Solar Energy LLC TXI10-400108BB is a 400.0 W STC (374.9 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.51% efficiency, 37.04 V Voc at 25 C, and 40.57 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
374.9 W
Voc @ 25C
37.04 V
Efficiency
20.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mission Solar Energy LLC TXI10-400108BB Compare Against Peer CEC Listings?

Engineering position of Mission Solar Energy LLC TXI10-400108BB (400.0 W STC) vs. CertainTeed CTM10400HC11-06 across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,407 across 21,677 CEC solar panels (top 45.5%; higher than 54.5% of peers), Mission Solar Energy LLC TXI10-400108BB operates as a modern high-density residential and light-commercial module sitting 10.0 W below the 410.0 W Mono-c-Si median. Lower 37.04 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677), 20 panels occupy 420 sq ft and offset roughly $2,002/yr at average US rates (or $3,386/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Mission Solar Energy LLC TXI10-400108BB Fall Across Listed CEC Models?

Plots Mission Solar Energy LLC TXI10-400108BB at 400.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mission Solar Energy LLC TXI10-400108BB (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMission Solar Ener: 400.0 W

What Dataset Percentiles Define Mission Solar Energy LLC TXI10-400108BB?

Benchmarks Mission Solar Energy LLC TXI10-400108BB on STC wattage, thermal PTC/STC retention, and 20.51 aperture conversion efficiency against CEC peers.

Mission Solar Energy LLC TXI10-400108BB Engineering BenchmarksPercentile comparison of Mission Solar Energy LLC TXI10-400108BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention93.7%Module Efficiency20.51%

What Do the Dataset Ranks Show for Mission Solar Energy LLC TXI10-400108BB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Mission Solar Energy LLC TXI10-400108BB by Mission Solar Energy LLC.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,487

20.51% Aperture Efficiency

Power density 205.1 W/m2 (0.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.57 V at -10 C (568.0 V string) and 41.57 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 39.0 m2 (420 sq ft) producing 7,498 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.04 * (1 + (-0.272/100) * (-10 - 25)) = 40.57 V | OCPD = 1.56 * 13.79 = 21.51 A

Inputs from CEC Modules.csv for Mission Solar Energy LLC TXI10-400108BB: Voc=37.04 V, beta_Voc=-0.272%/C, Isc=13.79 A, STC=400.0 W, Area=1.95 m2.

Result: 14 panels max on 600 V (568.0 V); 20 panels for 8 kW (420 sq ft).

What Are the Published CEC Specifications for Mission Solar Energy LLC TXI10-400108BB?

Laboratory test ratings recorded for Mission Solar Energy LLC TXI10-400108BB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Mission Solar Energy LLC TXI10-400108BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 374.9 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.04 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.79 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.01 V / 12.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.51% (1.95 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Mission Solar Energy LLC TXI10-400108BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (420 sq ft at 8 kW), and estimated Year-1 electric bill offset for Mission Solar Energy LLC TXI10-400108BB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 315 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 420 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 525 sq ft $2,503 $4,232

How Many Mission Solar Energy LLC TXI10-400108BB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Mission Solar Energy LLC TXI10-400108BB (beta_Voc -0.272%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.04V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.57 V 14 panels 582.0 V 24 panels
-10 C (14 F) 40.57 V 14 panels 568.0 V 24 panels
0 C (32 F) 39.56 V 15 panels 593.4 V 25 panels
25 C (77 F STC) 37.04 V 16 panels 592.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Mission Solar Energy LLC TXI10-400108BB?

Closest cross-brand CEC competitors to Mission Solar Energy LLC TXI10-400108BB matched near 400.0 W STC and 37.04 V Voc, led by CertainTeed CTM10400HC11-06.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10400HC11-06
CertainTeed
400.0 W Tie (0 W) 37.04 V 20.51% 93.7%
Apollo Renewables Inc Apollo-M754BH-400BB
Apollo Renewables Inc
400.0 W Tie (0 W) 37.07 V 20.62% 93.7%
CertainTeed CTM10400HC11-09
CertainTeed
400.0 W Tie (0 W) 37.2 V 20.62% 93.9%
CSI Solar Co Ltd CS6R-405MS-HL {Blk}
CSI Solar Co Ltd
405.0 W +5.0 W 37.0 V 20.77% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mission Solar Energy LLC TXI10-400108BB?

Evaluate Mission Solar Energy LLC TXI10-400108BB (400.0 W STC, 37.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mission Solar Energy LLC TXI10-400108BB reaches 41.57 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 420 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (420 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Mission Solar Energy LLC TXI10-400108BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mission Solar Energy LLC TXI10-400108BB 8 kW Residential Fit

Needs 20 modules (420 sq ft) with a 25 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CertainTeed CTM10400HC11-06.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 374.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mission Solar Energy LLC TXI10-400108BB by Mission Solar Energy LLC grounded in CEC test data and NEC 690.7/690.8 limits.

How many Mission Solar Energy LLC TXI10-400108BB panels fit on a 600 V winter solar string?

At -10 C (14 F), Mission Solar Energy LLC TXI10-400108BB cold Voc rises from 37.04 V to 40.57 V (beta_Voc -0.272%/C), capping a 600 V string at 14 panels (568.0 V).

How much roof area does an 8 kW array of Mission Solar Energy LLC TXI10-400108BB need?

An 8 kW DC system uses 20 Mission Solar Energy LLC TXI10-400108BB modules (8,000 W STC / 7,498 W PTC), covering roughly 420 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does Mission Solar Energy LLC TXI10-400108BB compare against CertainTeed CTM10400HC11-06?

Mission Solar Energy LLC TXI10-400108BB outputs 400.0 W STC (37.04 V Voc, rank #9,407 of 21,677), while CertainTeed CTM10400HC11-06 delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.