Merlin Solar Technologies Inc FX160S is a 160.0 W STC (146.5 W PTC) Mono-c-Si solar module ranking #21,373 of 21,677 CEC listings (below all-CEC median; higher than 1.3% of peers). It delivers 15.18% efficiency, 23.12 V Voc at 25 C, and 25.63 V cold Voc at -10 C (23 panels max per 600 V string).
- STC Wattage
- 160.0 W
- PTC Wattage
- 146.5 W
- Voc @ 25C
- 23.12 V
- Efficiency
- 15.18%
How Does Merlin Solar Technologies Inc FX160S Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Merlin Solar Technologies Inc FX160S (Mono-c-Si) residential solar systems.
Homeowners evaluating Merlin Solar Technologies Inc FX160S need 38 panels for 6 kW or 50 panels (567 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 50 panels (567 sq ft). Under NEC 690.7(A), beta_Voc (-0.31%/C) pushes open-circuit voltage to 25.63 V at 14 F and 26.35 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Merlin Solar Technologies Inc FX160S Fall Across Listed CEC Models?
Comparison of Merlin Solar Technologies Inc FX160S (160.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Merlin Solar Technologies Inc FX160S?
Relative ranking of Merlin Solar Technologies Inc FX160S across nameplate watts, 91.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Merlin Solar Technologies Inc FX160S?
Summary of Merlin Solar Technologies Inc FX160S output rank, 8 kW array size (50 panels), efficiency rating, and 600 V string limit.
160.0 W STC · Higher Than 1.3%
160.0 W STC (-225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.18% Aperture Efficiency
Power density 151.8 W/m2 (4.73 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).
23 Panels Max @ -10 C (600 V)
Cold Voc reaches 25.63 V at -10 C (589.5 V string) and 26.35 V at -20 C (22 max).
50 Panels = 8,000 W STC
Occupies 52.7 m2 (567 sq ft) producing 7,325 W PTC; NEC 690.8 OCPD floor is 13.85 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 23.12 * (1 + (-0.31/100) * (-10 - 25)) = 25.63 V | OCPD = 1.56 * 8.88 = 13.85 A
Inputs from CEC Modules.csv for Merlin Solar Technologies Inc FX160S: Voc=23.12 V, beta_Voc=-0.31%/C, Isc=8.88 A, STC=160.0 W, Area=1.054 m2.
Result: 23 panels max on 600 V (589.5 V); 50 panels for 8 kW (567 sq ft).
What Are the Published CEC Specifications for Merlin Solar Technologies Inc FX160S?
Complete CEC test sheet for Merlin Solar Technologies Inc FX160S including Isc (8.88 A), Voc (23.12 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 160.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 146.5 W (91.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 23.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 18.89 V / 8.55 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.18% (1.054 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Merlin Solar Technologies Inc FX160S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Merlin Solar Technologies Inc FX160S.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 38 | 6.08 kW | 431 sq ft | $1,522 | $2,573 |
| 8 kW Class | 50 | 8.0 kW | 567 sq ft | $2,002 | $3,386 |
| 10 kW Class | 63 | 10.08 kW | 715 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Merlin Solar Technologies Inc Series?
Related Merlin Solar Technologies Inc power steps and black/silver trims consolidated into this Merlin Solar Technologies Inc FX160S series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Merlin Solar Technologies Inc FX155S | 155.0 W | 141.8 W | 22.94 V | 18.8 V | 14.71% |
| Merlin Solar Technologies Inc FX160S | 160.0 W | 146.5 W | 23.12 V | 18.89 V | 15.18% |
| Merlin Solar Technologies Inc FX165S | 165.0 W | 151.2 W | 23.28 V | 18.98 V | 15.65% |
How Many Merlin Solar Technologies Inc FX160S Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Merlin Solar Technologies Inc FX160S (23.12 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 26.35 V | 22 panels | 579.7 V | 37 panels |
| -10 C (14 F) | 25.63 V | 23 panels | 589.5 V | 39 panels |
| 0 C (32 F) | 24.91 V | 24 panels | 597.8 V | 40 panels |
| 25 C (77 F STC) | 23.12 V | 25 panels | 578.0 V | 43 panels |
Which Cross-Brand Solar Modules Compare Closest to Merlin Solar Technologies Inc FX160S?
Four comparable CEC modules such as Walters & Wolf Glass Co VL-A200-1-0804-160W-M (160.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Walters & Wolf Glass Co VL-A200-1-0804-160W-M Walters & Wolf Glass Co |
160.0 W | Tie (0 W) | 22.13 V | 15.53% | 92.9% |
| Auxin Solar AXN6M409T155 Auxin Solar |
155.0 W | -5.0 W | 22.68 V | 15.82% | 89.5% |
| Trina Solar TSM-160PEG4007 Trina Solar |
160.0 W | Tie (0 W) | 24.9 V | 9.73% | 87.9% |
| Gintung Energy ASEC-155G6S49 Gintung Energy |
155.0 W | -5.0 W | 22.58 V | 15.71% | 87.7% |
What Are the Design Limits and Best-Fit Uses for Merlin Solar Technologies Inc FX160S?
Evaluate Merlin Solar Technologies Inc FX160S (160.0 W STC, 23.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Merlin Solar Technologies Inc FX160S reaches 26.35 V per panel—exceeding 22 panels in series voids 600 V inverter warranties.
- Footprint constraint: 50 panels for an 8 kW build require 567 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 50 panels (567 sq ft).
- 2026 tax credit baseline: cash residential installs of Merlin Solar Technologies Inc FX160S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Merlin Solar Technologies Inc FX160S 8 kW Residential Fit
Needs 50 modules (567 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 23 panels (-10 C) or 22 panels (-20 C), or compare Walters & Wolf Glass Co VL-A200-1-0804-160W-M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 146.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Merlin Solar Technologies Inc FX160S by Merlin Solar Technologies Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Merlin Solar Technologies Inc FX160S PTC wattage (146.5 W) lower than STC (160.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 146.5 W PTC (91.6% retention) across Merlin Solar Technologies Inc FX160S's 1.054 m2 aperture.
Who should skip Merlin Solar Technologies Inc FX160S on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 50 Merlin Solar Technologies Inc FX160S panels (567 sq ft) leave unusable roof gaps vs. Walters & Wolf Glass Co VL-A200-1-0804-160W-M.
What is the 1,000 V commercial string limit for Merlin Solar Technologies Inc FX160S?
On 1,000 V commercial inverters at -10 C (25.63 V cold Voc), Merlin Solar Technologies Inc FX160S fits up to 39 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)