Lumos S48-285-29-IM is a 285.0 W STC (264.4 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.77% efficiency, 32.8 V Voc at 25 C, and 36.52 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 264.4 W
- Voc @ 25C
- 32.8 V
- Efficiency
- 14.77%
How Does Lumos S48-285-29-IM Compare Against Peer CEC Listings?
Solar engineering breakdown for Lumos S48-285-29-IM: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Measured at 285.0 W STC and 264.4 W PTC, Lumos S48-285-29-IM sits -100.0 W vs all-CEC median (below all-CEC median; higher than 17.3% of peers) among 21,677 listed modules. Power density reaches 147.7 W/m2 (5.14 percentage points below 19.91% CEC median). Lower 32.8 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 27 panels in series. Alternative peer Auxin Solar AXN6M610B295 rates 295.0 W.
Where Does Lumos S48-285-29-IM Fall Across Listed CEC Models?
Distribution marker showing Lumos S48-285-29-IM (285.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Lumos S48-285-29-IM?
Dataset percentiles tracking Lumos S48-285-29-IM power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Lumos S48-285-29-IM?
Benchmark highlights for Lumos S48-285-29-IM covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.77% Aperture Efficiency
Power density 147.7 W/m2 (5.14 percentage points below 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.52 V at -10 C (584.3 V string) and 37.58 V at -20 C (15 max).
29 Panels = 8,265 W STC
Occupies 56.0 m2 (602 sq ft) producing 7,668 W PTC; NEC 690.8 OCPD floor is 17.78 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 32.8 * (1 + (-0.324/100) * (-10 - 25)) = 36.52 V | OCPD = 1.56 * 11.4 = 17.78 A
Inputs from CEC Modules.csv for Lumos S48-285-29-IM: Voc=32.8 V, beta_Voc=-0.324%/C, Isc=11.4 A, STC=285.0 W, Area=1.93 m2.
Result: 16 panels max on 600 V (584.3 V); 29 panels for 8 kW (602 sq ft).
What Are the Published CEC Specifications for Lumos S48-285-29-IM?
Official CEC datasheet figures for Lumos S48-285-29-IM (Mono-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 264.4 W (92.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 32.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.4 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.6 V / 10.78 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.77% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Lumos S48-285-29-IM Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Lumos S48-285-29-IM modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 457 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 602 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 748 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Lumos Series?
Consolidated Lumos wattage variants sharing the Lumos S48-285-29-IM mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Lumos S48-275-29-IM | 275.0 W | 255.0 W | 32.6 V | 26.4 V | 14.25% |
| Lumos S48-280-29-IM | 280.0 W | 259.7 W | 32.7 V | 26.5 V | 14.51% |
| Lumos S48-285-29-IM | 285.0 W | 264.4 W | 32.8 V | 26.6 V | 14.77% |
| Lumos S48-290-29-IM | 290.0 W | 269.1 W | 32.9 V | 26.8 V | 15.03% |
How Many Lumos S48-285-29-IM Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Lumos S48-285-29-IM (36.52 V at 14 F). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.58 V | 15 panels | 563.7 V | 26 panels |
| -10 C (14 F) | 36.52 V | 16 panels | 584.3 V | 27 panels |
| 0 C (32 F) | 35.46 V | 16 panels | 567.4 V | 28 panels |
| 25 C (77 F STC) | 32.8 V | 18 panels | 590.4 V | 30 panels |
Which Cross-Brand Solar Modules Compare Closest to Lumos S48-285-29-IM?
Competing CEC solar panels closest to Lumos S48-285-29-IM in nameplate wattage and Voc, starting with Auxin Solar AXN6M610B295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610B295 Auxin Solar |
295.0 W | +10.0 W | 40.11 V | 17.85% | 92.9% |
| CSI Solar Co Ltd CS6PH-280P CSI Solar Co Ltd |
280.0 W | -5.0 W | 35.4 V | 18.06% | 93.0% |
| CSI Solar Co Ltd CS6PH-290M CSI Solar Co Ltd |
290.0 W | +5.0 W | 36.9 V | 18.71% | 92.8% |
| GermanSolar USA Inc GSP-285W-H GermanSolar USA Inc |
285.0 W | Tie (0 W) | 38.16 V | 16.86% | 92.6% |
What Are the Design Limits and Best-Fit Uses for Lumos S48-285-29-IM?
Evaluate Lumos S48-285-29-IM (285.0 W STC, 32.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lumos S48-285-29-IM reaches 37.58 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 602 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (602 sq ft).
- 2026 tax credit baseline: cash residential installs of Lumos S48-285-29-IM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lumos S48-285-29-IM 8 kW Residential Fit
Needs 29 modules (602 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Auxin Solar AXN6M610B295.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 264.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lumos S48-285-29-IM by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
How many Lumos S48-285-29-IM panels fit on a 600 V winter solar string?
At -10 C (14 F), Lumos S48-285-29-IM cold Voc rises from 32.8 V to 36.52 V (beta_Voc -0.324%/C), capping a 600 V string at 16 panels (584.3 V).
How much roof area does an 8 kW array of Lumos S48-285-29-IM need?
An 8 kW DC system uses 29 Lumos S48-285-29-IM modules (8,265 W STC / 7,668 W PTC), covering roughly 602 sq ft and saving ~$2,070/yr at 18.54 c/kWh.
How does Lumos S48-285-29-IM compare against Auxin Solar AXN6M610B295?
Lumos S48-285-29-IM outputs 285.0 W STC (32.8 V Voc, rank #17,598 of 21,677), while Auxin Solar AXN6M610B295 delivers 295.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)