Lumos S48-270-29-IM is a 270.0 W STC (250.2 W PTC) Mono-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 13.99% efficiency, 32.5 V Voc at 25 C, and 36.19 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 250.2 W
- Voc @ 25C
- 32.5 V
- Efficiency
- 13.99%
How Does Lumos S48-270-29-IM Compare Against Peer CEC Listings?
How Lumos Lumos S48-270-29-IM handles rooftop heat (250.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Lumos S48-270-29-IM exhibits 11.1 A short-circuit current, requiring a 17.32 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #18,572 of 21,677 (140.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 57.9 m2 for an 8 kW system (38 panels for 10 kW). Lower 32.5 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.
Where Does Lumos S48-270-29-IM Fall Across Listed CEC Models?
Where Lumos S48-270-29-IM (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Lumos S48-270-29-IM?
Percentile placement of Lumos S48-270-29-IM across power density (139.9 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Lumos S48-270-29-IM?
Four critical engineering numbers homeowners and solar installers check first when reviewing Lumos S48-270-29-IM specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
13.99% Aperture Efficiency
Power density 139.9 W/m2 (5.92 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 36.19 V at -10 C (579.0 V string) and 37.24 V at -20 C (16 max).
30 Panels = 8,100 W STC
Occupies 57.9 m2 (623 sq ft) producing 7,506 W PTC; NEC 690.8 OCPD floor is 17.32 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 32.5 * (1 + (-0.324/100) * (-10 - 25)) = 36.19 V | OCPD = 1.56 * 11.1 = 17.32 A
Inputs from CEC Modules.csv for Lumos S48-270-29-IM: Voc=32.5 V, beta_Voc=-0.324%/C, Isc=11.1 A, STC=270.0 W, Area=1.93 m2.
Result: 16 panels max on 600 V (579.0 V); 30 panels for 8 kW (623 sq ft).
What Are the Published CEC Specifications for Lumos S48-270-29-IM?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Lumos S48-270-29-IM. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 250.2 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 32.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.23 V / 10.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.324 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.99% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Lumos S48-270-29-IM Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Lumos S48-270-29-IM (270.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 478 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 623 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 789 sq ft | $2,568 | $4,342 |
How Many Lumos S48-270-29-IM Modules Fit in a Cold-Weather String?
Maximum series module counts for Lumos S48-270-29-IM from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 37.24 V | 16 panels | 595.8 V | 26 panels |
| -10 C (14 F) | 36.19 V | 16 panels | 579.0 V | 27 panels |
| 0 C (32 F) | 35.13 V | 17 panels | 597.2 V | 28 panels |
| 25 C (77 F STC) | 32.5 V | 18 panels | 585.0 V | 30 panels |
Which Cross-Brand Solar Modules Compare Closest to Lumos S48-270-29-IM?
Alternative CEC solar modules from competing brands near Lumos S48-270-29-IM (270.0 W), including CSI Solar Co Ltd CS6PH-260P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6PH-260P CSI Solar Co Ltd |
260.0 W | -10.0 W | 34.6 V | 16.77% | 92.8% |
| Auxin Solar AXN6M610B295 Auxin Solar |
295.0 W | +25.0 W | 40.11 V | 17.85% | 92.9% |
| CSI Solar Co Ltd CS6PH-280P CSI Solar Co Ltd |
280.0 W | +10.0 W | 35.4 V | 18.06% | 93.0% |
| GermanSolar USA Inc GSP-270W GermanSolar USA Inc |
270.0 W | Tie (0 W) | 37.92 V | 16.27% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Lumos S48-270-29-IM?
Evaluate Lumos S48-270-29-IM (270.0 W STC, 32.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Lumos S48-270-29-IM reaches 37.24 V per panel—exceeding 16 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 623 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (623 sq ft).
- 2026 tax credit baseline: cash residential installs of Lumos S48-270-29-IM carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Lumos S48-270-29-IM 8 kW Residential Fit
Needs 30 modules (623 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 16 panels (-20 C), or compare CSI Solar Co Ltd CS6PH-260P.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 250.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Lumos S48-270-29-IM by Lumos grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Why is Lumos S48-270-29-IM PTC wattage (250.2 W) lower than STC (270.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.2 W PTC (92.7% retention) across Lumos S48-270-29-IM's 1.93 m2 aperture.
Who should skip Lumos S48-270-29-IM on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Lumos S48-270-29-IM panels (623 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6PH-260P.
What is the 1,000 V commercial string limit for Lumos S48-270-29-IM?
On 1,000 V commercial inverters at -10 C (36.19 V cold Voc), Lumos S48-270-29-IM fits up to 27 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Lumos S48-270-29-IM.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)