LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M is a 430.0 W STC (405.2 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 19.72% efficiency, 49.6 V Voc at 25 C, and 54.22 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 430.0 W
- PTC Wattage
- 405.2 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 19.72%
How Does LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M Compare Against Peer CEC Listings?
Engineering position of LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M (430.0 W STC) vs. Aptos Solar Technology LLC DNA-144-BF26-435W across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M pairs strong 94.2% PTC-to-STC heat retention (#3,689 of 21,677) with 49.6 V nominal Voc. An 8 kW residential build (8,170 W DC, 7,699 W PTC) saves ~$2,045/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Aptos Solar Technology LLC DNA-144-BF26-435W offers a 435.0 W alternative.
Where Does LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M Fall Across Listed CEC Models?
Plots LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M at 430.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M?
Benchmarks LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M on STC wattage, thermal PTC/STC retention, and 19.72 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M by LONGi Green Energy Technology Co Ltd.
Top 35.2% STC Output
430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.72% Aperture Efficiency
Power density 197.2 W/m2 (0.19 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.22 V at -10 C (596.4 V string) and 55.54 V at -20 C (10 max).
19 Panels = 8,170 W STC
Occupies 41.4 m2 (446 sq ft) producing 7,699 W PTC; NEC 690.8 OCPD floor is 17.3 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.266/100) * (-10 - 25)) = 54.22 V | OCPD = 1.56 * 11.09 = 17.3 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M: Voc=49.6 V, beta_Voc=-0.266%/C, Isc=11.09 A, STC=430.0 W, Area=2.18 m2.
Result: 11 panels max on 600 V (596.4 V); 19 panels for 8 kW (446 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M?
Laboratory test ratings recorded for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 405.2 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.2 V / 10.44 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.72% (2.18 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (446 sq ft at 8 kW), and estimated Year-1 electric bill offset for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.02 kW | 329 sq ft | $1,507 | $2,548 |
| 8 kW Class | 19 | 8.17 kW | 446 sq ft | $2,045 | $3,458 |
| 10 kW Class | 24 | 10.32 kW | 563 sq ft | $2,583 | $4,368 |
Which Sibling Wattage & Trim Variants Belong to This LONGi Green Energy Technology Co Ltd Series?
Sibling wattage bins and frame colors grouped with LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M under LONGi Green Energy Technology Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LONGi Green Energy Technology Co Ltd LR4-72HIBD-425M | 425.0 W | 400.3 W | 49.4 V | 41.0 V | 19.5% |
| LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M | 430.0 W | 405.2 W | 49.6 V | 41.2 V | 19.72% |
| LONGi Green Energy Technology Co Ltd LR4-72HIBD-435M | 435.0 W | 410.0 W | 49.8 V | 41.4 V | 19.95% |
How Many LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M (beta_Voc -0.266%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.54 V | 10 panels | 555.4 V | 18 panels |
| -10 C (14 F) | 54.22 V | 11 panels | 596.4 V | 18 panels |
| 0 C (32 F) | 52.9 V | 11 panels | 581.9 V | 18 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M?
Closest cross-brand CEC competitors to LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M matched near 430.0 W STC and 49.6 V Voc, led by Aptos Solar Technology LLC DNA-144-BF26-435W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-BF26-435W Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.38 V | 20.71% | 92.3% |
| Caterpillar Inc PVC435MB03H Caterpillar Inc |
435.0 W | +5.0 W | 49.1 V | 20.62% | 93.7% |
| CSI Solar Co Ltd CS3W-435PB-AG CSI Solar Co Ltd |
435.0 W | +5.0 W | 48.6 V | 20.05% | 93.4% |
| CSI Solar Co Ltd CS3W-435MB-AG CSI Solar Co Ltd |
435.0 W | +5.0 W | 48.5 V | 20.14% | 92.8% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M?
Evaluate LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M (430.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M reaches 55.54 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 446 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (446 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M 8 kW Residential Fit
Needs 19 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BF26-435W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 405.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M?
Multiplying LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M's 11.09 A short-circuit current by 1.56 equals 17.3 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.22 V cold Voc at 14 F and handles 11.09 A Isc; string inverters cap LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M at 11 panels on 600 V.
Is LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)