LONGi Green Energy Technology Co Ltd LR4-60HBD-345M is a 345.0 W STC (321.2 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 18.85% efficiency, 40.7 V Voc at 25 C, and 44.52 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 321.2 W
- Voc @ 25C
- 40.7 V
- Efficiency
- 18.85%
How Does LONGi Green Energy Technology Co Ltd LR4-60HBD-345M Compare Against Peer CEC Listings?
How LONGi Green Energy Technology Co Ltd LONGi Green Energy Technology Co Ltd LR4-60HBD-345M handles rooftop heat (321.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, LONGi Green Energy Technology Co Ltd LR4-60HBD-345M exhibits 10.88 A short-circuit current, requiring a 16.97 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #13,309 of 21,677 (65.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.9 m2 for an 8 kW system (29 panels for 10 kW). Mid-range 40.7 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does LONGi Green Energy Technology Co Ltd LR4-60HBD-345M Fall Across Listed CEC Models?
Where LONGi Green Energy Technology Co Ltd LR4-60HBD-345M (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define LONGi Green Energy Technology Co Ltd LR4-60HBD-345M?
Percentile placement of LONGi Green Energy Technology Co Ltd LR4-60HBD-345M across power density (188.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M?
Four critical engineering numbers homeowners and solar installers check first when reviewing LONGi Green Energy Technology Co Ltd LR4-60HBD-345M specifications.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.85% Aperture Efficiency
Power density 188.5 W/m2 (1.06 percentage points below 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.52 V at -10 C (578.8 V string) and 45.61 V at -20 C (13 max).
24 Panels = 8,280 W STC
Occupies 43.9 m2 (473 sq ft) producing 7,709 W PTC; NEC 690.8 OCPD floor is 16.97 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.7 * (1 + (-0.268/100) * (-10 - 25)) = 44.52 V | OCPD = 1.56 * 10.88 = 16.97 A
Inputs from CEC Modules.csv for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M: Voc=40.7 V, beta_Voc=-0.268%/C, Isc=10.88 A, STC=345.0 W, Area=1.83 m2.
Result: 13 panels max on 600 V (578.8 V); 24 panels for 8 kW (473 sq ft).
What Are the Published CEC Specifications for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 321.2 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.88 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.7 V / 10.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.85% (1.83 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Bifacial glass-glass |
How Many LONGi Green Energy Technology Co Ltd LR4-60HBD-345M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LONGi Green Energy Technology Co Ltd LR4-60HBD-345M (345.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 355 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 473 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 571 sq ft | $2,505 | $4,236 |
How Many LONGi Green Energy Technology Co Ltd LR4-60HBD-345M Modules Fit in a Cold-Weather String?
Maximum series module counts for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.61 V | 13 panels | 592.9 V | 21 panels |
| -10 C (14 F) | 44.52 V | 13 panels | 578.8 V | 22 panels |
| 0 C (32 F) | 43.43 V | 13 panels | 564.6 V | 23 panels |
| 25 C (77 F STC) | 40.7 V | 14 panels | 569.8 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to LONGi Green Energy Technology Co Ltd LR4-60HBD-345M?
Alternative CEC solar modules from competing brands near LONGi Green Energy Technology Co Ltd LR4-60HBD-345M (345.0 W), including Aptos Solar Technology LLC DNA-120-BF23-335W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-BF23-335W Aptos Solar Technology LLC |
335.0 W | -10.0 W | 40.46 V | 20.21% | 92.6% |
| CSI Solar Co Ltd CS3L-335PB-AG CSI Solar Co Ltd |
335.0 W | -10.0 W | 39.4 V | 18.41% | 93.4% |
| CSI Solar Co Ltd CS3U-345PB-AG CSI Solar Co Ltd |
345.0 W | Tie (0 W) | 46.4 V | 17.78% | 92.4% |
| Auxin Solar AXN6M612B345 Auxin Solar |
345.0 W | Tie (0 W) | 47.28 V | 17.52% | 92.9% |
What Are the Design Limits and Best-Fit Uses for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M?
Evaluate LONGi Green Energy Technology Co Ltd LR4-60HBD-345M (345.0 W STC, 40.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LONGi Green Energy Technology Co Ltd LR4-60HBD-345M reaches 45.61 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 473 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (473 sq ft).
- 2026 tax credit baseline: cash residential installs of LONGi Green Energy Technology Co Ltd LR4-60HBD-345M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LONGi Green Energy Technology Co Ltd LR4-60HBD-345M 8 kW Residential Fit
Needs 24 modules (473 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-BF23-335W.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 321.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M by LONGi Green Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is LONGi Green Energy Technology Co Ltd LR4-60HBD-345M PTC wattage (321.2 W) lower than STC (345.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 321.2 W PTC (93.1% retention) across LONGi Green Energy Technology Co Ltd LR4-60HBD-345M's 1.83 m2 aperture.
Who should skip LONGi Green Energy Technology Co Ltd LR4-60HBD-345M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 LONGi Green Energy Technology Co Ltd LR4-60HBD-345M panels (473 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-120-BF23-335W.
What is the 1,000 V commercial string limit for LONGi Green Energy Technology Co Ltd LR4-60HBD-345M?
On 1,000 V commercial inverters at -10 C (44.52 V cold Voc), LONGi Green Energy Technology Co Ltd LR4-60HBD-345M fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)