Skip to main content
WireAndSun
Calculators
CEC PV Module

Lightway Green New Energy LW300(35)P1960x990 — CEC Solar Module Specifications

Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW300(35)P1960x990 is a 300.0 W STC (268.6 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.46% efficiency, 45.08 V Voc at 25 C, and 50.92 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
268.6 W
Voc @ 25C
45.08 V
Efficiency
15.46%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW300(35)P1960x990 Compare Against Peer CEC Listings?

Engineering position of Lightway Green New Energy LW300(35)P1960x990 (300.0 W STC) vs. Auxin Solar AXN6P612T305G across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, Lightway Green New Energy LW300(35)P1960x990 pairs typical 89.5% PTC-to-STC thermal output (268.6 W real-world rating) with 45.08 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,252 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6P612T305G offers a 305.0 W alternative.

Where Does Lightway Green New Energy LW300(35)P1960x990 Fall Across Listed CEC Models?

Plots Lightway Green New Energy LW300(35)P1960x990 at 300.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW300(35)P1960x990 (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 300.0 W

What Dataset Percentiles Define Lightway Green New Energy LW300(35)P1960x990?

Benchmarks Lightway Green New Energy LW300(35)P1960x990 on STC wattage, thermal PTC/STC retention, and 15.46 aperture conversion efficiency against CEC peers.

Lightway Green New Energy LW300(35)P1960x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW300(35)P1960x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention89.5%Module Efficiency15.46%

What Do the Dataset Ranks Show for Lightway Green New Energy LW300(35)P1960x990?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Lightway Green New Energy LW300(35)P1960x990 by Lightway Green New Energy.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,977

15.46% Aperture Efficiency

Power density 154.6 W/m2 (4.45 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.92 V at -10 C (560.1 V string) and 52.59 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 52.4 m2 (564 sq ft) producing 7,252 W PTC; NEC 690.8 OCPD floor is 13.54 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.08 * (1 + (-0.37/100) * (-10 - 25)) = 50.92 V | OCPD = 1.56 * 8.68 = 13.54 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW300(35)P1960x990: Voc=45.08 V, beta_Voc=-0.37%/C, Isc=8.68 A, STC=300.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (560.1 V); 27 panels for 8 kW (564 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW300(35)P1960x990?

Laboratory test ratings recorded for Lightway Green New Energy LW300(35)P1960x990 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW300(35)P1960x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 268.6 W (89.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.08 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.68 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.15 V / 8.31 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.37 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.46% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW300(35)P1960x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (564 sq ft at 8 kW), and estimated Year-1 electric bill offset for Lightway Green New Energy LW300(35)P1960x990.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 418 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 564 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 710 sq ft $2,553 $4,317

How Many Lightway Green New Energy LW300(35)P1960x990 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Lightway Green New Energy LW300(35)P1960x990 (beta_Voc -0.37%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.08V and beta_Voc=-0.37%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.59 V 11 panels 578.5 V 19 panels
-10 C (14 F) 50.92 V 11 panels 560.1 V 19 panels
0 C (32 F) 49.25 V 12 panels 591.0 V 20 panels
25 C (77 F STC) 45.08 V 13 panels 586.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW300(35)P1960x990?

Closest cross-brand CEC competitors to Lightway Green New Energy LW300(35)P1960x990 matched near 300.0 W STC and 45.08 V Voc, led by Auxin Solar AXN6P612T305G.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W +5.0 W 45.0 V 15.63% 90.3%
AXITEC AC-310P/156-72S
AXITEC
310.0 W +10.0 W 45.05 V 16.01% 89.0%
Auxin Solar AXN6M612T310
Auxin Solar
310.0 W +10.0 W 45.0 V 15.89% 89.4%
Centrosolar America DP72 310
Centrosolar America
310.0 W +10.0 W 45.18 V 15.94% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW300(35)P1960x990?

Evaluate Lightway Green New Energy LW300(35)P1960x990 (300.0 W STC, 45.08 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW300(35)P1960x990 reaches 52.59 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 564 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (564 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW300(35)P1960x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW300(35)P1960x990 8 kW Residential Fit

Needs 27 modules (564 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW300(35)P1960x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Lightway Green New Energy LW300(35)P1960x990?

Multiplying Lightway Green New Energy LW300(35)P1960x990's 8.68 A short-circuit current by 1.56 equals 13.54 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Lightway Green New Energy LW300(35)P1960x990 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.92 V cold Voc at 14 F and handles 8.68 A Isc; string inverters cap Lightway Green New Energy LW300(35)P1960x990 at 11 panels on 600 V.

Is Lightway Green New Energy LW300(35)P1960x990 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lightway Green New Energy LW300(35)P1960x990 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.