Skip to main content
WireAndSun
Calculators
CEC PV Module

LENERGY POWER INC LP-410-108M-W — CEC Solar Module Specifications

Manufacturer: LENERGY POWER INC Registry: CEC Verified Engineering Specification

LENERGY POWER INC LP-410-108M-W is a 410.0 W STC (383.6 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.6 V Voc at 25 C, and 41.21 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
383.6 W
Voc @ 25C
37.6 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LENERGY POWER INC LP-410-108M-W Compare Against Peer CEC Listings?

How LENERGY POWER INC LENERGY POWER INC LP-410-108M-W handles rooftop heat (383.6 W PTC), 8 kW sizing, and cold winter string voltage.

LENERGY POWER INC builds the LENERGY POWER INC LP-410-108M-W (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). Compared against Auxin Solar AXN10M410B (410.0 W), this model holds strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677). Lower 37.6 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.61 A overcurrent floor served by a 25 A breaker.

Where Does LENERGY POWER INC LP-410-108M-W Fall Across Listed CEC Models?

Where LENERGY POWER INC LP-410-108M-W (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LENERGY POWER INC LP-410-108M-W (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLENERGY POWER INC : 410.0 W

What Dataset Percentiles Define LENERGY POWER INC LP-410-108M-W?

Percentile placement of LENERGY POWER INC LP-410-108M-W across power density (211.3 W/m2), thermal retention, and nameplate STC wattage.

LENERGY POWER INC LP-410-108M-W Engineering BenchmarksPercentile comparison of LENERGY POWER INC LP-410-108M-W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.6%Module Efficiency21.13%

What Do the Dataset Ranks Show for LENERGY POWER INC LP-410-108M-W?

Four critical engineering numbers homeowners and solar installers check first when reviewing LENERGY POWER INC LP-410-108M-W specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.21 V at -10 C (576.9 V string) and 42.24 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,672 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.6 * (1 + (-0.274/100) * (-10 - 25)) = 41.21 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for LENERGY POWER INC LP-410-108M-W: Voc=37.6 V, beta_Voc=-0.274%/C, Isc=13.85 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (576.9 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for LENERGY POWER INC LP-410-108M-W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LENERGY POWER INC LP-410-108M-W.

Official California Energy Commission (NREL SAM) test parameters for LENERGY POWER INC LP-410-108M-W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 383.6 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.5 V / 13.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.274 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many LENERGY POWER INC LP-410-108M-W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LENERGY POWER INC LP-410-108M-W (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This LENERGY POWER INC Series?

All closely matched LENERGY POWER INC wattages and cosmetic trims sharing the LENERGY POWER INC LP-410-108M-W architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the LENERGY POWER INC LP-410-108M-W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LENERGY POWER INC LP-400-108M-W 400.0 W 374.0 W 37.1 V 31.1 V 20.62%
LENERGY POWER INC LP-405-108M-W 405.0 W 378.8 W 37.4 V 31.3 V 20.88%
LENERGY POWER INC LP-410-108M-W 410.0 W 383.6 W 37.6 V 31.5 V 21.13%
LENERGY POWER INC LP-420-108M-W 420.0 W 393.2 W 37.8 V 32.0 V 21.65%

How Many LENERGY POWER INC LP-410-108M-W Modules Fit in a Cold-Weather String?

Maximum series module counts for LENERGY POWER INC LP-410-108M-W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.6V and beta_Voc=-0.274%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.24 V 14 panels 591.4 V 23 panels
-10 C (14 F) 41.21 V 14 panels 576.9 V 24 panels
0 C (32 F) 40.18 V 14 panels 562.5 V 24 panels
25 C (77 F STC) 37.6 V 15 panels 564.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to LENERGY POWER INC LP-410-108M-W?

Alternative CEC solar modules from competing brands near LENERGY POWER INC LP-410-108M-W (410.0 W), including Auxin Solar AXN10M410B.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M410B
Auxin Solar
410.0 W Tie (0 W) 37.54 V 21.64% 94.0%
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M
DONGGUAN SUNWORTH SOLAR ENERGY CO LTD
410.0 W Tie (0 W) 37.51 V 21.58% 94.5%
Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.7 V 21.13% 94.3%
Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2
Aptos Solar Technology LLC
410.0 W Tie (0 W) 37.7 V 21.13% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LENERGY POWER INC LP-410-108M-W?

Evaluate LENERGY POWER INC LP-410-108M-W (410.0 W STC, 37.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LENERGY POWER INC LP-410-108M-W reaches 42.24 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of LENERGY POWER INC LP-410-108M-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LENERGY POWER INC LP-410-108M-W 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M410B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LENERGY POWER INC LP-410-108M-W by LENERGY POWER INC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LENERGY POWER INC LP-410-108M-W?

Multiplying LENERGY POWER INC LP-410-108M-W's 13.85 A short-circuit current by 1.56 equals 21.61 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can LENERGY POWER INC LP-410-108M-W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.21 V cold Voc at 14 F and handles 13.85 A Isc; string inverters cap LENERGY POWER INC LP-410-108M-W at 14 panels on 600 V.

Is LENERGY POWER INC LP-410-108M-W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LENERGY POWER INC LP-410-108M-W rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.