LENERGY POWER INC LP-535-144M-W is a 535.0 W STC (500.4 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.82% efficiency, 49.6 V Voc at 25 C, and 54.36 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 535.0 W
- PTC Wattage
- 500.4 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 20.82%
How Does LENERGY POWER INC LP-535-144M-W Compare Against Peer CEC Listings?
How LENERGY POWER INC LENERGY POWER INC LP-535-144M-W handles rooftop heat (500.4 W PTC), 8 kW sizing, and cold winter string voltage.
LENERGY POWER INC builds the LENERGY POWER INC LP-535-144M-W (Mono-c-Si) as a large-format commercial and ground-mount module delivering 208.2 W/m2 (0.91 percentage points above 19.91% CEC median). Compared against Chint New Energy Technology Co Ltd CHSM72M-HC-535 (535.0 W), this model holds strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677). Higher 49.6 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 21.26 A overcurrent floor served by a 25 A breaker.
Where Does LENERGY POWER INC LP-535-144M-W Fall Across Listed CEC Models?
Where LENERGY POWER INC LP-535-144M-W (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define LENERGY POWER INC LP-535-144M-W?
Percentile placement of LENERGY POWER INC LP-535-144M-W across power density (208.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for LENERGY POWER INC LP-535-144M-W?
Four critical engineering numbers homeowners and solar installers check first when reviewing LENERGY POWER INC LP-535-144M-W specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 17.5% STC Output
535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.82% Aperture Efficiency
Power density 208.2 W/m2 (0.91 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.36 V at -10 C (598.0 V string) and 55.72 V at -20 C (10 max).
15 Panels = 8,025 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,506 W PTC; NEC 690.8 OCPD floor is 21.26 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.274/100) * (-10 - 25)) = 54.36 V | OCPD = 1.56 * 13.63 = 21.26 A
Inputs from CEC Modules.csv for LENERGY POWER INC LP-535-144M-W: Voc=49.6 V, beta_Voc=-0.274%/C, Isc=13.63 A, STC=535.0 W, Area=2.57 m2.
Result: 11 panels max on 600 V (598.0 V); 15 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for LENERGY POWER INC LP-535-144M-W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for LENERGY POWER INC LP-535-144M-W.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 500.4 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.63 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.8 V / 12.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.274 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.82% (2.57 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many LENERGY POWER INC LP-535-144M-W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using LENERGY POWER INC LP-535-144M-W (535.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.42 kW | 332 sq ft | $1,607 | $2,717 |
| 8 kW Class | 15 | 8.03 kW | 415 sq ft | $2,010 | $3,398 |
| 10 kW Class | 19 | 10.16 kW | 526 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This LENERGY POWER INC Series?
All closely matched LENERGY POWER INC wattages and cosmetic trims sharing the LENERGY POWER INC LP-535-144M-W architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| LENERGY POWER INC LP-525-144M-W | 525.0 W | 490.8 W | 49.2 V | 41.4 V | 20.43% |
| LENERGY POWER INC LP-530-144M-W | 530.0 W | 495.6 W | 49.4 V | 41.6 V | 20.62% |
| LENERGY POWER INC LP-535-144M-W | 535.0 W | 500.4 W | 49.6 V | 41.8 V | 20.82% |
| LENERGY POWER INC LP-540-144M-W | 540.0 W | 505.2 W | 49.8 V | 42.0 V | 21.01% |
| LENERGY POWER INC LP-545-144M-W | 545.0 W | 510.0 W | 50.0 V | 42.2 V | 21.21% |
How Many LENERGY POWER INC LP-535-144M-W Modules Fit in a Cold-Weather String?
Maximum series module counts for LENERGY POWER INC LP-535-144M-W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.72 V | 10 panels | 557.2 V | 17 panels |
| -10 C (14 F) | 54.36 V | 11 panels | 598.0 V | 18 panels |
| 0 C (32 F) | 53.0 V | 11 panels | 583.0 V | 18 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to LENERGY POWER INC LP-535-144M-W?
Alternative CEC solar modules from competing brands near LENERGY POWER INC LP-535-144M-W (535.0 W), including Chint New Energy Technology Co Ltd CHSM72M-HC-535.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM72M-HC-535 Chint New Energy Technology Co Ltd |
535.0 W | Tie (0 W) | 49.5 V | 21.57% | 92.6% |
| Heliene 144HC-535 M10 SL Heliene |
535.0 W | Tie (0 W) | 49.47 V | 21.49% | 93.5% |
| ELITE Solar ET-M772BH535GL ELITE Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.9% | 94.1% |
| Hyperion Solar HY-WH144P8-535 Hyperion Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.74% | 92.8% |
What Are the Design Limits and Best-Fit Uses for LENERGY POWER INC LP-535-144M-W?
Evaluate LENERGY POWER INC LP-535-144M-W (535.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), LENERGY POWER INC LP-535-144M-W reaches 55.72 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 415 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of LENERGY POWER INC LP-535-144M-W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
LENERGY POWER INC LP-535-144M-W 8 kW Residential Fit
Needs 15 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72M-HC-535.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 500.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for LENERGY POWER INC LP-535-144M-W by LENERGY POWER INC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for LENERGY POWER INC LP-535-144M-W?
Multiplying LENERGY POWER INC LP-535-144M-W's 13.63 A short-circuit current by 1.56 equals 21.26 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can LENERGY POWER INC LP-535-144M-W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.36 V cold Voc at 14 F and handles 13.63 A Isc; string inverters cap LENERGY POWER INC LP-535-144M-W at 11 panels on 600 V.
Is LENERGY POWER INC LP-535-144M-W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LENERGY POWER INC LP-535-144M-W rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)