Juli New Energy JLS230P — CEC Solar Module Specifications

Manufacturer: Juli New Energy Registry: CEC Verified Engineering Specification

Juli New Energy JLS230P is a 230.0 W STC (200.5 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.05% efficiency, 36.0 V Voc at 25 C, and 40.81 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
230.0 W
PTC Wattage
200.5 W
Voc @ 25C
36.0 V
Efficiency
14.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Juli New Energy JLS230P Compare Against Peer CEC Listings?

How Juli New Energy Juli New Energy JLS230P handles rooftop heat (200.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Juli New Energy JLS230P exhibits 8.59 A short-circuit current, requiring a 13.4 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,522 of 21,677 (48.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.3 m2 for an 8 kW system (44 panels for 10 kW). Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Juli New Energy JLS230P Fall Across Listed CEC Models?

Where Juli New Energy JLS230P (230.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Juli New Energy JLS230P (230.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJuli New Energy JL: 230.0 W

What Dataset Percentiles Define Juli New Energy JLS230P?

Percentile placement of Juli New Energy JLS230P across power density (140.5 W/m2), thermal retention, and nameplate STC wattage.

Juli New Energy JLS230P Engineering BenchmarksPercentile comparison of Juli New Energy JLS230P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage230.0 WPTC/STC Retention87.2%Module Efficiency14.05%

What Do the Dataset Ranks Show for Juli New Energy JLS230P?

Four critical engineering numbers homeowners and solar installers check first when reviewing Juli New Energy JLS230P specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #20,522 / 21,677

230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,865

14.05% Aperture Efficiency

Power density 140.5 W/m2 (5.86 percentage points below 19.91% CEC median). PTC/STC ratio: 87.2% (rank #21,580).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.81 V at -10 C (571.3 V string) and 42.19 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,050 W STC

Occupies 57.3 m2 (617 sq ft) producing 7,018 W PTC; NEC 690.8 OCPD floor is 13.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.0 * (1 + (-0.382/100) * (-10 - 25)) = 40.81 V | OCPD = 1.56 * 8.59 = 13.4 A

Inputs from CEC Modules.csv for Juli New Energy JLS230P: Voc=36.0 V, beta_Voc=-0.382%/C, Isc=8.59 A, STC=230.0 W, Area=1.637 m2.

Result: 14 panels max on 600 V (571.3 V); 35 panels for 8 kW (617 sq ft).

What Are the Published CEC Specifications for Juli New Energy JLS230P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Juli New Energy JLS230P.

Official California Energy Commission (NREL SAM) test parameters for Juli New Energy JLS230P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 230.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 200.5 W (87.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.0 V / 7.67 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.382 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.05% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Juli New Energy JLS230P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Juli New Energy JLS230P (230.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.21 kW 476 sq ft $1,554 $2,628
8 kW Class 35 8.05 kW 617 sq ft $2,015 $3,407
10 kW Class 44 10.12 kW 775 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Juli New Energy Series?

All closely matched Juli New Energy wattages and cosmetic trims sharing the Juli New Energy JLS230P architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Juli New Energy JLS230P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Juli New Energy JLS225P 225.0 W 196.0 W 35.4 V 29.5 V 13.75%
Juli New Energy JLS230P 230.0 W 200.5 W 36.0 V 30.0 V 14.05%

How Many Juli New Energy JLS230P Modules Fit in a Cold-Weather String?

Maximum series module counts for Juli New Energy JLS230P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.0V and beta_Voc=-0.382%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.19 V 14 panels 590.7 V 23 panels
-10 C (14 F) 40.81 V 14 panels 571.3 V 24 panels
0 C (32 F) 39.44 V 15 panels 591.6 V 25 panels
25 C (77 F STC) 36.0 V 16 panels 576.0 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Juli New Energy JLS230P?

Alternative CEC solar modules from competing brands near Juli New Energy JLS230P (230.0 W), including Gintung Energy ASEC-230G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-230G6S
Gintung Energy
230.0 W Tie (0 W) 36.75 V 14.28% 89.7%
Grape Solar GS-P-230-CS
Grape Solar
230.0 W Tie (0 W) 36.8 V 14.3% 91.7%
Gintung Energy ASEC-230G6M
Gintung Energy
230.0 W Tie (0 W) 36.87 V 14.28% 89.4%
Anji Dasol Solar Energy Science & Technology DS-A4-230
Anji Dasol Solar Energy Science & Technology
230.0 W Tie (0 W) 36.9 V 13.97% 87.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Juli New Energy JLS230P?

Evaluate Juli New Energy JLS230P (230.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Juli New Energy JLS230P reaches 42.19 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
  • 2026 tax credit baseline: cash residential installs of Juli New Energy JLS230P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Juli New Energy JLS230P 8 kW Residential Fit

Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintung Energy ASEC-230G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 200.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Juli New Energy JLS230P by Juli New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Juli New Energy JLS230P PTC wattage (200.5 W) lower than STC (230.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 200.5 W PTC (87.2% retention) across Juli New Energy JLS230P's 1.637 m2 aperture.

Who should skip Juli New Energy JLS230P on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Juli New Energy JLS230P panels (617 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-230G6S.

What is the 1,000 V commercial string limit for Juli New Energy JLS230P?

On 1,000 V commercial inverters at -10 C (40.81 V cold Voc), Juli New Energy JLS230P fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Juli New Energy JLS230P.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.