Juli New Energy JLS230P is a 230.0 W STC (200.5 W PTC) Multi-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.05% efficiency, 36.0 V Voc at 25 C, and 40.81 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 230.0 W
- PTC Wattage
- 200.5 W
- Voc @ 25C
- 36.0 V
- Efficiency
- 14.05%
How Does Juli New Energy JLS230P Compare Against Peer CEC Listings?
How Juli New Energy Juli New Energy JLS230P handles rooftop heat (200.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Juli New Energy JLS230P exhibits 8.59 A short-circuit current, requiring a 13.4 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,522 of 21,677 (48.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.3 m2 for an 8 kW system (44 panels for 10 kW). Lower 36.0 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Juli New Energy JLS230P Fall Across Listed CEC Models?
Where Juli New Energy JLS230P (230.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Juli New Energy JLS230P?
Percentile placement of Juli New Energy JLS230P across power density (140.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Juli New Energy JLS230P?
Four critical engineering numbers homeowners and solar installers check first when reviewing Juli New Energy JLS230P specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
230.0 W STC · Higher Than 4.7%
230.0 W STC (-155.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.05% Aperture Efficiency
Power density 140.5 W/m2 (5.86 percentage points below 19.91% CEC median). PTC/STC ratio: 87.2% (rank #21,580).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.81 V at -10 C (571.3 V string) and 42.19 V at -20 C (14 max).
35 Panels = 8,050 W STC
Occupies 57.3 m2 (617 sq ft) producing 7,018 W PTC; NEC 690.8 OCPD floor is 13.4 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.0 * (1 + (-0.382/100) * (-10 - 25)) = 40.81 V | OCPD = 1.56 * 8.59 = 13.4 A
Inputs from CEC Modules.csv for Juli New Energy JLS230P: Voc=36.0 V, beta_Voc=-0.382%/C, Isc=8.59 A, STC=230.0 W, Area=1.637 m2.
Result: 14 panels max on 600 V (571.3 V); 35 panels for 8 kW (617 sq ft).
What Are the Published CEC Specifications for Juli New Energy JLS230P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Juli New Energy JLS230P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 230.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 200.5 W (87.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.0 V / 7.67 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.382 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.05% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Juli New Energy JLS230P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Juli New Energy JLS230P (230.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 27 | 6.21 kW | 476 sq ft | $1,554 | $2,628 |
| 8 kW Class | 35 | 8.05 kW | 617 sq ft | $2,015 | $3,407 |
| 10 kW Class | 44 | 10.12 kW | 775 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Juli New Energy Series?
All closely matched Juli New Energy wattages and cosmetic trims sharing the Juli New Energy JLS230P architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Juli New Energy JLS225P | 225.0 W | 196.0 W | 35.4 V | 29.5 V | 13.75% |
| Juli New Energy JLS230P | 230.0 W | 200.5 W | 36.0 V | 30.0 V | 14.05% |
How Many Juli New Energy JLS230P Modules Fit in a Cold-Weather String?
Maximum series module counts for Juli New Energy JLS230P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.19 V | 14 panels | 590.7 V | 23 panels |
| -10 C (14 F) | 40.81 V | 14 panels | 571.3 V | 24 panels |
| 0 C (32 F) | 39.44 V | 15 panels | 591.6 V | 25 panels |
| 25 C (77 F STC) | 36.0 V | 16 panels | 576.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Juli New Energy JLS230P?
Alternative CEC solar modules from competing brands near Juli New Energy JLS230P (230.0 W), including Gintung Energy ASEC-230G6S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-230G6S Gintung Energy |
230.0 W | Tie (0 W) | 36.75 V | 14.28% | 89.7% |
| Grape Solar GS-P-230-CS Grape Solar |
230.0 W | Tie (0 W) | 36.8 V | 14.3% | 91.7% |
| Gintung Energy ASEC-230G6M Gintung Energy |
230.0 W | Tie (0 W) | 36.87 V | 14.28% | 89.4% |
| Anji Dasol Solar Energy Science & Technology DS-A4-230 Anji Dasol Solar Energy Science & Technology |
230.0 W | Tie (0 W) | 36.9 V | 13.97% | 87.3% |
What Are the Design Limits and Best-Fit Uses for Juli New Energy JLS230P?
Evaluate Juli New Energy JLS230P (230.0 W STC, 36.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Juli New Energy JLS230P reaches 42.19 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
- 2026 tax credit baseline: cash residential installs of Juli New Energy JLS230P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Juli New Energy JLS230P 8 kW Residential Fit
Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Gintung Energy ASEC-230G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 200.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Juli New Energy JLS230P by Juli New Energy grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Juli New Energy JLS230P PTC wattage (200.5 W) lower than STC (230.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 200.5 W PTC (87.2% retention) across Juli New Energy JLS230P's 1.637 m2 aperture.
Who should skip Juli New Energy JLS230P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Juli New Energy JLS230P panels (617 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-230G6S.
What is the 1,000 V commercial string limit for Juli New Energy JLS230P?
On 1,000 V commercial inverters at -10 C (40.81 V cold Voc), Juli New Energy JLS230P fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Juli New Energy JLS230P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)