Skip to main content
WireAndSun
Calculators
CEC PV Module

Juli New Energy JLS220P — CEC Solar Module Specifications

Manufacturer: Juli New Energy Registry: CEC Verified Engineering Specification

Juli New Energy JLS220P is a 220.0 W STC (191.5 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.44% efficiency, 35.4 V Voc at 25 C, and 40.13 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
220.0 W
PTC Wattage
191.5 W
Voc @ 25C
35.4 V
Efficiency
13.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Juli New Energy JLS220P Compare Against Peer CEC Listings?

Engineering position of Juli New Energy JLS220P (220.0 W STC) vs. Alps Technology ATI-M660-220 across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Juli New Energy JLS220P pairs typical 87.0% PTC-to-STC thermal output (191.5 W real-world rating) with 35.4 V nominal Voc. An 8 kW residential build (8,140 W DC, 7,086 W PTC) saves ~$2,037/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Alps Technology ATI-M660-220 offers a 220.0 W alternative.

Where Does Juli New Energy JLS220P Fall Across Listed CEC Models?

Plots Juli New Energy JLS220P at 220.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Juli New Energy JLS220P (220.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJuli New Energy JL: 220.0 W

What Dataset Percentiles Define Juli New Energy JLS220P?

Benchmarks Juli New Energy JLS220P on STC wattage, thermal PTC/STC retention, and 13.44 aperture conversion efficiency against CEC peers.

Juli New Energy JLS220P Engineering BenchmarksPercentile comparison of Juli New Energy JLS220P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage220.0 WPTC/STC Retention87.0%Module Efficiency13.44%

What Do the Dataset Ranks Show for Juli New Energy JLS220P?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Juli New Energy JLS220P by Juli New Energy.

Rank #20,759 / 21,677

220.0 W STC · Higher Than 3.8%

220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,235

13.44% Aperture Efficiency

Power density 134.4 W/m2 (6.47 percentage points below 19.91% CEC median). PTC/STC ratio: 87.0% (rank #21,595).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.13 V at -10 C (561.8 V string) and 41.49 V at -20 C (14 max).

8 kW Reference Array

37 Panels = 8,140 W STC

Occupies 60.6 m2 (652 sq ft) producing 7,086 W PTC; NEC 690.8 OCPD floor is 13.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 35.4 * (1 + (-0.382/100) * (-10 - 25)) = 40.13 V | OCPD = 1.56 * 8.36 = 13.04 A

Inputs from CEC Modules.csv for Juli New Energy JLS220P: Voc=35.4 V, beta_Voc=-0.382%/C, Isc=8.36 A, STC=220.0 W, Area=1.637 m2.

Result: 14 panels max on 600 V (561.8 V); 37 panels for 8 kW (652 sq ft).

What Are the Published CEC Specifications for Juli New Energy JLS220P?

Laboratory test ratings recorded for Juli New Energy JLS220P (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Juli New Energy JLS220P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 220.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 191.5 W (87.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 35.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.5 V / 7.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.382 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.44% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Juli New Energy JLS220P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (652 sq ft at 8 kW), and estimated Year-1 electric bill offset for Juli New Energy JLS220P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 28 6.16 kW 493 sq ft $1,542 $2,607
8 kW Class 37 8.14 kW 652 sq ft $2,037 $3,445
10 kW Class 46 10.12 kW 811 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Juli New Energy Series?

Sibling wattage bins and frame colors grouped with Juli New Energy JLS220P under Juli New Energy to prevent duplicate spec pages.

Sibling CEC listings grouped into the Juli New Energy JLS220P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Juli New Energy JLS215P 215.0 W 188.6 W 34.8 V 29.0 V 16.84%
Juli New Energy JLS220P 220.0 W 191.5 W 35.4 V 29.5 V 13.44%

How Many Juli New Energy JLS220P Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Juli New Energy JLS220P (beta_Voc -0.382%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=35.4V and beta_Voc=-0.382%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.49 V 14 panels 580.9 V 24 panels
-10 C (14 F) 40.13 V 14 panels 561.8 V 24 panels
0 C (32 F) 38.78 V 15 panels 581.7 V 25 panels
25 C (77 F STC) 35.4 V 16 panels 566.4 V 28 panels

Which Cross-Brand Solar Modules Compare Closest to Juli New Energy JLS220P?

Closest cross-brand CEC competitors to Juli New Energy JLS220P matched near 220.0 W STC and 35.4 V Voc, led by Alps Technology ATI-M660-220.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Alps Technology ATI-M660-220
Alps Technology
220.0 W Tie (0 W) 36.06 V 13.67% 86.0%
Anji Technology AJP-M660-220
Anji Technology
220.0 W Tie (0 W) 36.06 V 13.55% 86.0%
Centrosolar America DP60 220
Centrosolar America
220.0 W Tie (0 W) 36.26 V 13.42% 89.8%
Anhui Rinengzhongtian Semiconductor Development QJM220-60
Anhui Rinengzhongtian Semiconductor Development
220.0 W Tie (0 W) 36.29 V 13.52% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Juli New Energy JLS220P?

Evaluate Juli New Energy JLS220P (220.0 W STC, 35.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Juli New Energy JLS220P reaches 41.49 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 37 panels for an 8 kW build require 652 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (652 sq ft).
  • 2026 tax credit baseline: cash residential installs of Juli New Energy JLS220P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Juli New Energy JLS220P 8 kW Residential Fit

Needs 37 modules (652 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Alps Technology ATI-M660-220.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 191.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Juli New Energy JLS220P by Juli New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Juli New Energy JLS220P?

Multiplying Juli New Energy JLS220P's 8.36 A short-circuit current by 1.56 equals 13.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Juli New Energy JLS220P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.13 V cold Voc at 14 F and handles 8.36 A Isc; string inverters cap Juli New Energy JLS220P at 14 panels on 600 V.

Is Juli New Energy JLS220P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Juli New Energy JLS220P rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.