Jinko Solar Co Ltd JKMS295PP-72 is a 295.0 W STC (266.2 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.2% efficiency, 42.8 V Voc at 25 C, and 47.79 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 266.2 W
- Voc @ 25C
- 42.8 V
- Efficiency
- 15.2%
How Does Jinko Solar Co Ltd JKMS295PP-72 Compare Against Peer CEC Listings?
How Jinko Solar Co Ltd Jinko Solar Co Ltd JKMS295PP-72 handles rooftop heat (266.2 W PTC), 8 kW sizing, and cold winter string voltage.
Jinko Solar Co Ltd builds the Jinko Solar Co Ltd JKMS295PP-72 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 152.1 W/m2 (4.71 percentage points below 19.91% CEC median). Compared against Chinaland Solar Energy HSE295-72P (295.0 W), this model holds typical 90.2% PTC-to-STC thermal output (266.2 W real-world rating). Mid-range 42.8 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.38 A overcurrent floor served by a 15 A breaker.
Where Does Jinko Solar Co Ltd JKMS295PP-72 Fall Across Listed CEC Models?
Where Jinko Solar Co Ltd JKMS295PP-72 (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKMS295PP-72?
Percentile placement of Jinko Solar Co Ltd JKMS295PP-72 across power density (152.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKMS295PP-72?
Four critical engineering numbers homeowners and solar installers check first when reviewing Jinko Solar Co Ltd JKMS295PP-72 specifications.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.2% Aperture Efficiency
Power density 152.1 W/m2 (4.71 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.79 V at -10 C (573.5 V string) and 49.21 V at -20 C (12 max).
28 Panels = 8,260 W STC
Occupies 54.3 m2 (585 sq ft) producing 7,454 W PTC; NEC 690.8 OCPD floor is 14.38 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 42.8 * (1 + (-0.333/100) * (-10 - 25)) = 47.79 V | OCPD = 1.56 * 9.22 = 14.38 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKMS295PP-72: Voc=42.8 V, beta_Voc=-0.333%/C, Isc=9.22 A, STC=295.0 W, Area=1.94 m2.
Result: 12 panels max on 600 V (573.5 V); 28 panels for 8 kW (585 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKMS295PP-72?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Jinko Solar Co Ltd JKMS295PP-72.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 266.2 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 42.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.4 V / 8.58 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.333 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.2% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKMS295PP-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Jinko Solar Co Ltd JKMS295PP-72 (295.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 439 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 585 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 710 sq ft | $2,510 | $4,245 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
All closely matched Jinko Solar Co Ltd wattages and cosmetic trims sharing the Jinko Solar Co Ltd JKMS295PP-72 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKMS290PP-72 | 290.0 W | 261.6 W | 42.7 V | 34.0 V | 14.95% |
| Jinko Solar Co Ltd JKMS295PP-72 | 295.0 W | 266.2 W | 42.8 V | 34.4 V | 15.2% |
How Many Jinko Solar Co Ltd JKMS295PP-72 Modules Fit in a Cold-Weather String?
Maximum series module counts for Jinko Solar Co Ltd JKMS295PP-72 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.21 V | 12 panels | 590.5 V | 20 panels |
| -10 C (14 F) | 47.79 V | 12 panels | 573.5 V | 20 panels |
| 0 C (32 F) | 46.36 V | 12 panels | 556.3 V | 21 panels |
| 25 C (77 F STC) | 42.8 V | 14 panels | 599.2 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKMS295PP-72?
Alternative CEC solar modules from competing brands near Jinko Solar Co Ltd JKMS295PP-72 (295.0 W), including Chinaland Solar Energy HSE295-72P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE295-72P Chinaland Solar Energy |
295.0 W | Tie (0 W) | 43.3 V | 15.28% | 88.5% |
| Chinaland Solar Energy HSE295-72M Chinaland Solar Energy |
295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
| BYD Company Limited BYD295P6K-36 BYD Company Limited |
295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| Centrosolar America TP7 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKMS295PP-72?
Evaluate Jinko Solar Co Ltd JKMS295PP-72 (295.0 W STC, 42.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKMS295PP-72 reaches 49.21 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 585 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (585 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKMS295PP-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKMS295PP-72 8 kW Residential Fit
Needs 28 modules (585 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Chinaland Solar Energy HSE295-72P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 266.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKMS295PP-72 by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jinko Solar Co Ltd JKMS295PP-72?
Multiplying Jinko Solar Co Ltd JKMS295PP-72's 9.22 A short-circuit current by 1.56 equals 14.38 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Jinko Solar Co Ltd JKMS295PP-72 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 47.79 V cold Voc at 14 F and handles 9.22 A Isc; string inverters cap Jinko Solar Co Ltd JKMS295PP-72 at 12 panels on 600 V.
Is Jinko Solar Co Ltd JKMS295PP-72 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jinko Solar Co Ltd JKMS295PP-72 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)