Jinko Solar Co Ltd JKM380M-72H is a 380.0 W STC (350.5 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.0% efficiency, 48.9 V Voc at 25 C, and 54.65 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 350.5 W
- Voc @ 25C
- 48.9 V
- Efficiency
- 20.0%
How Does Jinko Solar Co Ltd JKM380M-72H Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Jinko Solar Co Ltd JKM380M-72H (Mono-c-Si) residential solar systems.
Jinko Solar Co Ltd JKM380M-72H delivers 200.0 W/m2 (0.09 percentage points above 19.91% CEC median) and strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (450 sq ft). At -4 F (-20 C), string voltage climbs to 56.29 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Caterpillar Inc PVC380MP03H (380.0 W).
Where Does Jinko Solar Co Ltd JKM380M-72H Fall Across Listed CEC Models?
Comparison of Jinko Solar Co Ltd JKM380M-72H (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM380M-72H?
Relative ranking of Jinko Solar Co Ltd JKM380M-72H across nameplate watts, 92.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM380M-72H?
Summary of Jinko Solar Co Ltd JKM380M-72H output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.0% Aperture Efficiency
Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.65 V at -10 C (546.5 V string) and 56.29 V at -20 C (10 max).
22 Panels = 8,360 W STC
Occupies 41.8 m2 (450 sq ft) producing 7,711 W PTC; NEC 690.8 OCPD floor is 15.21 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.9 * (1 + (-0.336/100) * (-10 - 25)) = 54.65 V | OCPD = 1.56 * 9.75 = 15.21 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM380M-72H: Voc=48.9 V, beta_Voc=-0.336%/C, Isc=9.75 A, STC=380.0 W, Area=1.9 m2.
Result: 10 panels max on 600 V (546.5 V); 22 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM380M-72H?
Complete CEC test sheet for Jinko Solar Co Ltd JKM380M-72H including Isc (9.75 A), Voc (48.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 350.5 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.75 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.5 V / 9.39 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.336 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.0% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 144 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM380M-72H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Jinko Solar Co Ltd JKM380M-72H.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 327 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 450 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 552 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Jinko Solar Co Ltd Series?
Related Jinko Solar Co Ltd power steps and black/silver trims consolidated into this Jinko Solar Co Ltd JKM380M-72H series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jinko Solar Co Ltd JKM375M-72H | 375.0 W | 345.8 W | 48.7 V | 40.2 V | 19.74% |
| Jinko Solar Co Ltd JKM380M-72H | 380.0 W | 350.5 W | 48.9 V | 40.5 V | 20.0% |
| Jinko Solar Co Ltd JKM385M-72H | 385.0 W | 355.3 W | 49.1 V | 40.8 V | 20.26% |
How Many Jinko Solar Co Ltd JKM380M-72H Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Jinko Solar Co Ltd JKM380M-72H (48.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.29 V | 10 panels | 562.9 V | 17 panels |
| -10 C (14 F) | 54.65 V | 10 panels | 546.5 V | 18 panels |
| 0 C (32 F) | 53.01 V | 11 panels | 583.1 V | 18 panels |
| 25 C (77 F STC) | 48.9 V | 12 panels | 586.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM380M-72H?
Four comparable CEC modules such as Caterpillar Inc PVC380MP03H (380.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
| Caterpillar Inc PVC380MP03 Caterpillar Inc |
380.0 W | Tie (0 W) | 49.03 V | 20.21% | 93.5% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM380M-72H?
Evaluate Jinko Solar Co Ltd JKM380M-72H (380.0 W STC, 48.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM380M-72H reaches 56.29 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (450 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM380M-72H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM380M-72H 8 kW Residential Fit
Needs 22 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC380MP03H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM380M-72H by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Jinko Solar Co Ltd JKM380M-72H panels fit on a 600 V winter solar string?
At -10 C (14 F), Jinko Solar Co Ltd JKM380M-72H cold Voc rises from 48.9 V to 54.65 V (beta_Voc -0.336%/C), capping a 600 V string at 10 panels (546.5 V).
How much roof area does an 8 kW array of Jinko Solar Co Ltd JKM380M-72H need?
An 8 kW DC system uses 22 Jinko Solar Co Ltd JKM380M-72H modules (8,360 W STC / 7,711 W PTC), covering roughly 450 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Jinko Solar Co Ltd JKM380M-72H compare against Caterpillar Inc PVC380MP03H?
Jinko Solar Co Ltd JKM380M-72H outputs 380.0 W STC (48.9 V Voc, rank #11,043 of 21,677), while Caterpillar Inc PVC380MP03H delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)