Jinko Solar Co Ltd JKM370M-72HBL is a 370.0 W STC (340.6 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 18.97% efficiency, 48.5 V Voc at 25 C, and 53.76 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 340.6 W
- Voc @ 25C
- 48.5 V
- Efficiency
- 18.97%
How Does Jinko Solar Co Ltd JKM370M-72HBL Compare Against Peer CEC Listings?
Solar engineering breakdown for Jinko Solar Co Ltd JKM370M-72HBL: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 370.0 W STC and 340.6 W PTC, Jinko Solar Co Ltd JKM370M-72HBL sits -15.0 W vs all-CEC median (below all-CEC median; higher than 44.4% of peers) among 21,677 listed modules. Power density reaches 189.7 W/m2 (0.94 percentage points below 19.91% CEC median). Higher 48.5 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Caterpillar Inc PVC370MP03H rates 370.0 W.
Where Does Jinko Solar Co Ltd JKM370M-72HBL Fall Across Listed CEC Models?
Distribution marker showing Jinko Solar Co Ltd JKM370M-72HBL (370.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Jinko Solar Co Ltd JKM370M-72HBL?
Dataset percentiles tracking Jinko Solar Co Ltd JKM370M-72HBL power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Jinko Solar Co Ltd JKM370M-72HBL?
Benchmark highlights for Jinko Solar Co Ltd JKM370M-72HBL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.97% Aperture Efficiency
Power density 189.7 W/m2 (0.94 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.76 V at -10 C (591.4 V string) and 55.27 V at -20 C (10 max).
22 Panels = 8,140 W STC
Occupies 42.9 m2 (462 sq ft) producing 7,493 W PTC; NEC 690.8 OCPD floor is 14.99 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.5 * (1 + (-0.31/100) * (-10 - 25)) = 53.76 V | OCPD = 1.56 * 9.61 = 14.99 A
Inputs from CEC Modules.csv for Jinko Solar Co Ltd JKM370M-72HBL: Voc=48.5 V, beta_Voc=-0.31%/C, Isc=9.61 A, STC=370.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (591.4 V); 22 panels for 8 kW (462 sq ft).
What Are the Published CEC Specifications for Jinko Solar Co Ltd JKM370M-72HBL?
Official CEC datasheet figures for Jinko Solar Co Ltd JKM370M-72HBL (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 340.6 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.9 V / 9.28 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.97% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 24 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jinko Solar Co Ltd JKM370M-72HBL Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Jinko Solar Co Ltd JKM370M-72HBL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 357 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 462 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 588 sq ft | $2,593 | $4,385 |
How Many Jinko Solar Co Ltd JKM370M-72HBL Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Jinko Solar Co Ltd JKM370M-72HBL (53.76 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.27 V | 10 panels | 552.7 V | 18 panels |
| -10 C (14 F) | 53.76 V | 11 panels | 591.4 V | 18 panels |
| 0 C (32 F) | 52.26 V | 11 panels | 574.9 V | 19 panels |
| 25 C (77 F STC) | 48.5 V | 12 panels | 582.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jinko Solar Co Ltd JKM370M-72HBL?
Competing CEC solar panels closest to Jinko Solar Co Ltd JKM370M-72HBL in nameplate wattage and Voc, starting with Caterpillar Inc PVC370MP03H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVC370MP03H Caterpillar Inc |
370.0 W | Tie (0 W) | 48.6 V | 19.11% | 94.1% |
| Bluesun Solar Energy Tech CoLtd BSM370M-72 Bluesun Solar Energy Tech CoLtd |
370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| CertainTeed CT370M00-04 CertainTeed |
370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
| CertainTeed CT375M00-04 CertainTeed |
375.0 W | +5.0 W | 48.2 V | 19.93% | 93.3% |
What Are the Design Limits and Best-Fit Uses for Jinko Solar Co Ltd JKM370M-72HBL?
Evaluate Jinko Solar Co Ltd JKM370M-72HBL (370.0 W STC, 48.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jinko Solar Co Ltd JKM370M-72HBL reaches 55.27 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 462 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (462 sq ft).
- 2026 tax credit baseline: cash residential installs of Jinko Solar Co Ltd JKM370M-72HBL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jinko Solar Co Ltd JKM370M-72HBL 8 kW Residential Fit
Needs 22 modules (462 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC370MP03H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 340.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jinko Solar Co Ltd JKM370M-72HBL by Jinko Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Jinko Solar Co Ltd JKM370M-72HBL panels fit on a 600 V winter solar string?
At -10 C (14 F), Jinko Solar Co Ltd JKM370M-72HBL cold Voc rises from 48.5 V to 53.76 V (beta_Voc -0.31%/C), capping a 600 V string at 11 panels (591.4 V).
How much roof area does an 8 kW array of Jinko Solar Co Ltd JKM370M-72HBL need?
An 8 kW DC system uses 22 Jinko Solar Co Ltd JKM370M-72HBL modules (8,140 W STC / 7,493 W PTC), covering roughly 462 sq ft and saving ~$2,037/yr at 18.54 c/kWh.
How does Jinko Solar Co Ltd JKM370M-72HBL compare against Caterpillar Inc PVC370MP03H?
Jinko Solar Co Ltd JKM370M-72HBL outputs 370.0 W STC (48.5 V Voc, rank #11,697 of 21,677), while Caterpillar Inc PVC370MP03H delivers 370.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)