Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 is a 535.0 W STC (503.6 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.45 V Voc at 25 C, and 53.79 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 535.0 W
- PTC Wattage
- 503.6 W
- Voc @ 25C
- 49.45 V
- Efficiency
- 20.74%
How Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 Compare Against Peer CEC Listings?
Solar engineering breakdown for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Jiangsu Runergy New Energy Technology Co Ltd and peers, Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 stands 125.0 W above the 410.0 W Mono-c-Si median and strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,607-$2,543/yr in baseline US bill offset. Higher 49.45 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 Fall Across Listed CEC Models?
Distribution marker showing Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 (535.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535?
Dataset percentiles tracking Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535?
Benchmark highlights for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 17.5% STC Output
535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.74% Aperture Efficiency
Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.79 V at -10 C (591.7 V string) and 55.04 V at -20 C (10 max).
15 Panels = 8,025 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,554 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.45 * (1 + (-0.251/100) * (-10 - 25)) = 53.79 V | OCPD = 1.56 * 13.79 = 21.51 A
Inputs from CEC Modules.csv for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535: Voc=49.45 V, beta_Voc=-0.251%/C, Isc=13.79 A, STC=535.0 W, Area=2.58 m2.
Result: 11 panels max on 600 V (591.7 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535?
Official CEC datasheet figures for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 535.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 503.6 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.45 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.47 V / 12.9 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.74% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.42 kW | 333 sq ft | $1,607 | $2,717 |
| 8 kW Class | 15 | 8.03 kW | 417 sq ft | $2,010 | $3,398 |
| 10 kW Class | 19 | 10.16 kW | 528 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This Jiangsu Runergy New Energy Technology Co Ltd Series?
Consolidated Jiangsu Runergy New Energy Technology Co Ltd wattage variants sharing the Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-525 | 525.0 W | 493.9 W | 49.15 V | 41.15 V | 20.35% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-530 | 530.0 W | 498.7 W | 49.3 V | 41.31 V | 20.54% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 | 535.0 W | 503.6 W | 49.45 V | 41.47 V | 20.74% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-540 | 540.0 W | 508.4 W | 49.6 V | 41.64 V | 20.93% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-545 | 545.0 W | 513.2 W | 49.75 V | 41.8 V | 21.12% |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 (53.79 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.04 V | 10 panels | 550.4 V | 18 panels |
| -10 C (14 F) | 53.79 V | 11 panels | 591.7 V | 18 panels |
| 0 C (32 F) | 52.55 V | 11 panels | 578.0 V | 19 panels |
| 25 C (77 F STC) | 49.45 V | 12 panels | 593.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535?
Competing CEC solar panels closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 in nameplate wattage and Voc, starting with ELITE Solar ET-M772BH535GL.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-M772BH535GL ELITE Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.9% | 94.1% |
| Hyperion Solar HY-WH144P8-535 Hyperion Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.74% | 92.8% |
| Hyperion Solar HY-WH144P8-535-B {Blk} Hyperion Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.74% | 92.8% |
| Hyperion Solar HY-WH144P8-535-b {Wht} Hyperion Solar |
535.0 W | Tie (0 W) | 49.45 V | 20.74% | 92.8% |
What Are the Design Limits and Best-Fit Uses for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535?
Evaluate Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 (535.0 W STC, 49.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 reaches 55.04 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M772BH535GL.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 503.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 by Jiangsu Runergy New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535?
Multiplying Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535's 13.79 A short-circuit current by 1.56 equals 21.51 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.79 V cold Voc at 14 F and handles 13.79 A Isc; string inverters cap Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 at 11 panels on 600 V.
Is Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)