Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 is a 450.0 W STC (427.8 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 23.08% efficiency, 39.79 V Voc at 25 C, and 42.53 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 427.8 W
- Voc @ 25C
- 39.79 V
- Efficiency
- 23.08%
How Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 Compare Against Peer CEC Listings?
Solar engineering breakdown for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Jiangsu Runergy New Energy Technology Co Ltd and peers, Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 stands 40.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,577-$2,591/yr in baseline US bill offset. Lower 39.79 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 Fall Across Listed CEC Models?
Distribution marker showing Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 (450.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450?
Dataset percentiles tracking Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450?
Benchmark highlights for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.08% Aperture Efficiency
Power density 230.8 W/m2 (3.17 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.53 V at -10 C (595.4 V string) and 43.32 V at -20 C (13 max).
18 Panels = 8,100 W STC
Occupies 35.1 m2 (378 sq ft) producing 7,700 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.79 * (1 + (-0.197/100) * (-10 - 25)) = 42.53 V | OCPD = 1.56 * 14.0 = 21.84 A
Inputs from CEC Modules.csv for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450: Voc=39.79 V, beta_Voc=-0.197%/C, Isc=14.0 A, STC=450.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (595.4 V); 18 panels for 8 kW (378 sq ft).
What Are the Published CEC Specifications for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450?
Official CEC datasheet figures for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 427.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.79 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.22 V / 13.55 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.197 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.08% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 294 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 378 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 483 sq ft | $2,591 | $4,380 |
How Many Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 (42.53 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.32 V | 13 panels | 563.2 V | 23 panels |
| -10 C (14 F) | 42.53 V | 14 panels | 595.4 V | 23 panels |
| 0 C (32 F) | 41.75 V | 14 panels | 584.5 V | 23 panels |
| 25 C (77 F STC) | 39.79 V | 15 panels | 596.9 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450?
Competing CEC solar panels closest to Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 in nameplate wattage and Voc, starting with Auxin Solar AXN10M450B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M450B Auxin Solar |
450.0 W | Tie (0 W) | 39.75 V | 23.2% | 91.4% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T450NF(BK) HD HYUNDAI ENERGY SOLUTIONS CO LTD |
450.0 W | Tie (0 W) | 39.2 V | 23.2% | 94.9% |
| AXITEC AC-450TGB/108BB AXITEC |
450.0 W | Tie (0 W) | 38.8 V | 23.68% | 95.1% |
| ELITE Solar ET-N754TBH455GB ELITE Solar |
455.0 W | +5.0 W | 39.86 V | 23.33% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450?
Evaluate Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 (450.0 W STC, 39.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 reaches 43.32 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 378 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (378 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 8 kW Residential Fit
Needs 18 modules (378 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN10M450B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 by Jiangsu Runergy New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450?
Multiplying Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450's 14.0 A short-circuit current by 1.56 equals 21.84 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.53 V cold Voc at 14 F and handles 14.0 A Isc; string inverters cap Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 at 14 panels on 600 V.
Is Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)