JA Solar JAP72S01-315/SC — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP72S01-315/SC is a 315.0 W STC (290.7 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.76% efficiency, 45.85 V Voc at 25 C, and 50.71 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
290.7 W
Voc @ 25C
45.85 V
Efficiency
16.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP72S01-315/SC Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAP72S01-315/SC: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from JA Solar and peers, JA Solar JAP72S01-315/SC stands 36.2 W above the 278.8 W Multi-c-Si median and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Sizing 6 kW (20 panels) to 10 kW (32 panels) yields $1,577-$2,523/yr in baseline US bill offset. Mid-range 45.85 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does JA Solar JAP72S01-315/SC Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAP72S01-315/SC (315.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP72S01-315/SC (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP72S01-: 315.0 W

What Dataset Percentiles Define JA Solar JAP72S01-315/SC?

Dataset percentiles tracking JA Solar JAP72S01-315/SC power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAP72S01-315/SC Engineering BenchmarksPercentile comparison of JA Solar JAP72S01-315/SC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention92.3%Module Efficiency16.76%

What Do the Dataset Ranks Show for JA Solar JAP72S01-315/SC?

Benchmark highlights for JA Solar JAP72S01-315/SC covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,871

16.76% Aperture Efficiency

Power density 167.6 W/m2 (3.15 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.71 V at -10 C (557.8 V string) and 52.1 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 48.9 m2 (526 sq ft) producing 7,558 W PTC; NEC 690.8 OCPD floor is 14.06 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.85 * (1 + (-0.303/100) * (-10 - 25)) = 50.71 V | OCPD = 1.56 * 9.01 = 14.06 A

Inputs from CEC Modules.csv for JA Solar JAP72S01-315/SC: Voc=45.85 V, beta_Voc=-0.303%/C, Isc=9.01 A, STC=315.0 W, Area=1.88 m2.

Result: 11 panels max on 600 V (557.8 V); 26 panels for 8 kW (526 sq ft).

What Are the Published CEC Specifications for JA Solar JAP72S01-315/SC?

Official CEC datasheet figures for JA Solar JAP72S01-315/SC (Multi-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP72S01-315/SC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 290.7 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.01 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.09 V / 8.49 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.303 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.76% (1.88 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP72S01-315/SC Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAP72S01-315/SC modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 405 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 526 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 648 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAP72S01-315/SC mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the JA Solar JAP72S01-315/SC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP72S01-305/SC 305.0 W 281.2 W 45.27 V 36.78 V 16.22%
JA Solar JAP72S01-310/SC 310.0 W 286.0 W 45.56 V 36.89 V 16.49%
JA Solar JAP72S01-315/SC 315.0 W 290.7 W 45.85 V 37.09 V 16.76%
JA Solar JAP72S01-320/SC 320.0 W 295.4 W 46.12 V 37.28 V 17.02%

How Many JA Solar JAP72S01-315/SC Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAP72S01-315/SC (50.71 V at 14 F).

Computed from Voc=45.85V and beta_Voc=-0.303%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.1 V 11 panels 573.1 V 19 panels
-10 C (14 F) 50.71 V 11 panels 557.8 V 19 panels
0 C (32 F) 49.32 V 12 panels 591.8 V 20 panels
25 C (77 F STC) 45.85 V 13 panels 596.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP72S01-315/SC?

Competing CEC solar panels closest to JA Solar JAP72S01-315/SC in nameplate wattage and Voc, starting with Centrosolar America EP72 315BW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Boviet Solar Technology Co Ltd BVM6612M-315
Boviet Solar Technology Co Ltd
315.0 W Tie (0 W) 46.1 V 16.23% 90.5%
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP72S01-315/SC?

Evaluate JA Solar JAP72S01-315/SC (315.0 W STC, 45.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP72S01-315/SC reaches 52.1 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 526 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (526 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP72S01-315/SC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP72S01-315/SC 8 kW Residential Fit

Needs 26 modules (526 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America EP72 315BW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 290.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP72S01-315/SC by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAP72S01-315/SC?

Multiplying JA Solar JAP72S01-315/SC's 9.01 A short-circuit current by 1.56 equals 14.06 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAP72S01-315/SC pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.71 V cold Voc at 14 F and handles 9.01 A Isc; string inverters cap JA Solar JAP72S01-315/SC at 11 panels on 600 V.

Is JA Solar JAP72S01-315/SC eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP72S01-315/SC rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.