JA Solar JAP6(BK)-72-310/MP is a 310.0 W STC (274.4 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.99% efficiency, 45.81 V Voc at 25 C, and 51.33 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 274.4 W
- Voc @ 25C
- 45.81 V
- Efficiency
- 15.99%
How Does JA Solar JAP6(BK)-72-310/MP Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6(BK)-72-310/MP (Multi-c-Si) residential solar systems.
Homeowners evaluating JA Solar JAP6(BK)-72-310/MP need 20 panels for 6 kW or 26 panels (542 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). Under NEC 690.7(A), beta_Voc (-0.344%/C) pushes open-circuit voltage to 51.33 V at 14 F and 52.9 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAP6(BK)-72-310/MP Fall Across Listed CEC Models?
Comparison of JA Solar JAP6(BK)-72-310/MP (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAP6(BK)-72-310/MP?
Relative ranking of JA Solar JAP6(BK)-72-310/MP across nameplate watts, 88.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAP6(BK)-72-310/MP?
Summary of JA Solar JAP6(BK)-72-310/MP output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.99% Aperture Efficiency
Power density 160.0 W/m2 (3.92 percentage points below 19.91% CEC median). PTC/STC ratio: 88.5% (rank #21,133).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.33 V at -10 C (564.6 V string) and 52.9 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.4 m2 (542 sq ft) producing 7,134 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.81 * (1 + (-0.344/100) * (-10 - 25)) = 51.33 V | OCPD = 1.56 * 8.8 = 13.73 A
Inputs from CEC Modules.csv for JA Solar JAP6(BK)-72-310/MP: Voc=45.81 V, beta_Voc=-0.344%/C, Isc=8.8 A, STC=310.0 W, Area=1.938 m2.
Result: 11 panels max on 600 V (564.6 V); 26 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6(BK)-72-310/MP?
Complete CEC test sheet for JA Solar JAP6(BK)-72-310/MP including Isc (8.8 A), Voc (45.81 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 274.4 W (88.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.8 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.58 V / 8.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.344 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.99% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6(BK)-72-310/MP Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6(BK)-72-310/MP.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 417 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 688 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Related JA Solar power steps and black/silver trims consolidated into this JA Solar JAP6(BK)-72-310/MP series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6(BK)-72-300/MP | 300.0 W | 265.3 W | 45.67 V | 36.9 V | 15.48% |
| JA Solar JAP6(BK)-72-305/MP | 305.0 W | 269.9 W | 45.74 V | 37.24 V | 15.73% |
| JA Solar JAP6(BK)-72-310/MP | 310.0 W | 274.4 W | 45.81 V | 37.58 V | 15.99% |
| JA Solar JAP6(BK)-72-315/MP | 315.0 W | 279.0 W | 45.9 V | 37.91 V | 16.25% |
How Many JA Solar JAP6(BK)-72-310/MP Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAP6(BK)-72-310/MP (45.81 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.9 V | 11 panels | 581.9 V | 18 panels |
| -10 C (14 F) | 51.33 V | 11 panels | 564.6 V | 19 panels |
| 0 C (32 F) | 49.75 V | 12 panels | 597.0 V | 20 panels |
| 25 C (77 F STC) | 45.81 V | 13 panels | 595.5 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-72-310/MP?
Four comparable CEC modules such as Boviet Solar Technology Co Ltd BVM6612P-310 (310.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612P-310 Boviet Solar Technology Co Ltd |
310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| Centrosolar America CP72 310-C1 Centrosolar America |
310.0 W | Tie (0 W) | 45.8 V | 15.98% | 90.3% |
| BYD Company Limited BYD 310P6C-36 BYD Company Limited |
310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.2% |
| BYD Company Limited BYD310P6K-36 BYD Company Limited |
310.0 W | Tie (0 W) | 45.79 V | 15.98% | 91.6% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-72-310/MP?
Evaluate JA Solar JAP6(BK)-72-310/MP (310.0 W STC, 45.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-72-310/MP reaches 52.9 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-72-310/MP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6(BK)-72-310/MP 8 kW Residential Fit
Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6(BK)-72-310/MP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6(BK)-72-310/MP PTC wattage (274.4 W) lower than STC (310.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 274.4 W PTC (88.5% retention) across JA Solar JAP6(BK)-72-310/MP's 1.938 m2 aperture.
Who should skip JA Solar JAP6(BK)-72-310/MP on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 JA Solar JAP6(BK)-72-310/MP panels (542 sq ft) leave unusable roof gaps vs. Boviet Solar Technology Co Ltd BVM6612P-310.
What is the 1,000 V commercial string limit for JA Solar JAP6(BK)-72-310/MP?
On 1,000 V commercial inverters at -10 C (51.33 V cold Voc), JA Solar JAP6(BK)-72-310/MP fits up to 19 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)