JA Solar JAP6(BK)-60-220 is a 220.0 W STC (195.4 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.45% efficiency, 36.83 V Voc at 25 C, and 41.52 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 195.4 W
- Voc @ 25C
- 36.83 V
- Efficiency
- 13.45%
How Does JA Solar JAP6(BK)-60-220 Compare Against Peer CEC Listings?
How JA Solar JA Solar JAP6(BK)-60-220 handles rooftop heat (195.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, JA Solar JAP6(BK)-60-220 exhibits 8.14 A short-circuit current, requiring a 12.7 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,759 of 21,677 (58.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 60.5 m2 for an 8 kW system (46 panels for 10 kW). Lower 36.83 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does JA Solar JAP6(BK)-60-220 Fall Across Listed CEC Models?
Where JA Solar JAP6(BK)-60-220 (220.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAP6(BK)-60-220?
Percentile placement of JA Solar JAP6(BK)-60-220 across power density (134.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAP6(BK)-60-220?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6(BK)-60-220 specifications.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.45% Aperture Efficiency
Power density 134.6 W/m2 (6.46 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.52 V at -10 C (581.3 V string) and 42.86 V at -20 C (13 max).
37 Panels = 8,140 W STC
Occupies 60.5 m2 (651 sq ft) producing 7,230 W PTC; NEC 690.8 OCPD floor is 12.7 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.83 * (1 + (-0.364/100) * (-10 - 25)) = 41.52 V | OCPD = 1.56 * 8.14 = 12.7 A
Inputs from CEC Modules.csv for JA Solar JAP6(BK)-60-220: Voc=36.83 V, beta_Voc=-0.364%/C, Isc=8.14 A, STC=220.0 W, Area=1.635 m2.
Result: 14 panels max on 600 V (581.3 V); 37 panels for 8 kW (651 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6(BK)-60-220?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6(BK)-60-220.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 195.4 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.83 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.14 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 28.92 V / 7.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.364 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.45% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6(BK)-60-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6(BK)-60-220 (220.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 493 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 651 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 810 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6(BK)-60-220 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6(BK)-60-215 | 215.0 W | 190.9 W | 36.66 V | 28.72 V | 13.15% |
| JA Solar JAP6(BK)-60-220 | 220.0 W | 195.4 W | 36.83 V | 28.92 V | 13.45% |
How Many JA Solar JAP6(BK)-60-220 Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAP6(BK)-60-220 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.86 V | 13 panels | 557.2 V | 23 panels |
| -10 C (14 F) | 41.52 V | 14 panels | 581.3 V | 24 panels |
| 0 C (32 F) | 40.18 V | 14 panels | 562.5 V | 24 panels |
| 25 C (77 F STC) | 36.83 V | 16 panels | 589.3 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6(BK)-60-220?
Alternative CEC solar modules from competing brands near JA Solar JAP6(BK)-60-220 (220.0 W), including APOS Energy AS220.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| APOS Energy AS220 APOS Energy |
220.0 W | Tie (0 W) | 36.63 V | 13.26% | 89.5% |
| Grape Solar GS-P-220-CS Grape Solar |
220.0 W | Tie (0 W) | 36.6 V | 13.68% | 91.6% |
| Guangdong Golden Glass Technologies GG220M2-30/1640x992 Guangdong Golden Glass Technologies |
220.0 W | Tie (0 W) | 36.6 V | 13.52% | 90.2% |
| Greenlite Solar Canada GLS-220 Greenlite Solar Canada |
220.0 W | Tie (0 W) | 37.08 V | 13.63% | 90.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6(BK)-60-220?
Evaluate JA Solar JAP6(BK)-60-220 (220.0 W STC, 36.83 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6(BK)-60-220 reaches 42.86 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 651 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (651 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6(BK)-60-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6(BK)-60-220 8 kW Residential Fit
Needs 37 modules (651 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare APOS Energy AS220.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 195.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6(BK)-60-220 by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6(BK)-60-220 PTC wattage (195.4 W) lower than STC (220.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 195.4 W PTC (88.8% retention) across JA Solar JAP6(BK)-60-220's 1.635 m2 aperture.
Who should skip JA Solar JAP6(BK)-60-220 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 37 JA Solar JAP6(BK)-60-220 panels (651 sq ft) leave unusable roof gaps vs. APOS Energy AS220.
What is the 1,000 V commercial string limit for JA Solar JAP6(BK)-60-220?
On 1,000 V commercial inverters at -10 C (41.52 V cold Voc), JA Solar JAP6(BK)-60-220 fits up to 24 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)