JA Solar JAP6-72-330/3BB is a 330.0 W STC (298.5 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.02% efficiency, 46.05 V Voc at 25 C, and 51.05 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 298.5 W
- Voc @ 25C
- 46.05 V
- Efficiency
- 17.02%
How Does JA Solar JAP6-72-330/3BB Compare Against Peer CEC Listings?
Engineering position of JA Solar JAP6-72-330/3BB (330.0 W STC) vs. Advance Power API-P330 across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, JA Solar JAP6-72-330/3BB pairs typical 90.5% PTC-to-STC thermal output (298.5 W real-world rating) with 46.05 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,462 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Advance Power API-P330 offers a 330.0 W alternative.
Where Does JA Solar JAP6-72-330/3BB Fall Across Listed CEC Models?
Plots JA Solar JAP6-72-330/3BB at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAP6-72-330/3BB?
Benchmarks JA Solar JAP6-72-330/3BB on STC wattage, thermal PTC/STC retention, and 17.02 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAP6-72-330/3BB?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6-72-330/3BB by JA Solar.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.02% Aperture Efficiency
Power density 170.3 W/m2 (2.89 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.05 V at -10 C (561.5 V string) and 52.47 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.4 m2 (522 sq ft) producing 7,462 W PTC; NEC 690.8 OCPD floor is 14.18 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.05 * (1 + (-0.31/100) * (-10 - 25)) = 51.05 V | OCPD = 1.56 * 9.09 = 14.18 A
Inputs from CEC Modules.csv for JA Solar JAP6-72-330/3BB: Voc=46.05 V, beta_Voc=-0.31%/C, Isc=9.09 A, STC=330.0 W, Area=1.938 m2.
Result: 11 panels max on 600 V (561.5 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-72-330/3BB?
Laboratory test ratings recorded for JA Solar JAP6-72-330/3BB (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 298.5 W (90.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.11 V / 8.66 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.02% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-72-330/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6-72-330/3BB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 396 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAP6-72-330/3BB under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6-72-325/3BB | 325.0 W | 293.8 W | 45.9 V | 37.84 V | 16.77% |
| JA Solar JAP6-72-330/3BB | 330.0 W | 298.5 W | 46.05 V | 38.11 V | 17.02% |
How Many JA Solar JAP6-72-330/3BB Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAP6-72-330/3BB (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.47 V | 11 panels | 577.2 V | 19 panels |
| -10 C (14 F) | 51.05 V | 11 panels | 561.5 V | 19 panels |
| 0 C (32 F) | 49.62 V | 12 panels | 595.4 V | 20 panels |
| 25 C (77 F STC) | 46.05 V | 13 panels | 598.6 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-330/3BB?
Closest cross-brand CEC competitors to JA Solar JAP6-72-330/3BB matched near 330.0 W STC and 46.05 V Voc, led by Advance Power API-P330.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P330 Advance Power |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| Auxin Solar AXN6P612T330 Auxin Solar |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| Centrosolar America TM7 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| Centrosolar America TM7S 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-330/3BB?
Evaluate JA Solar JAP6-72-330/3BB (330.0 W STC, 46.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-330/3BB reaches 52.47 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-330/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-72-330/3BB 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P330.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 298.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-72-330/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-72-330/3BB?
Multiplying JA Solar JAP6-72-330/3BB's 9.09 A short-circuit current by 1.56 equals 14.18 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAP6-72-330/3BB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.05 V cold Voc at 14 F and handles 9.09 A Isc; string inverters cap JA Solar JAP6-72-330/3BB at 11 panels on 600 V.
Is JA Solar JAP6-72-330/3BB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-72-330/3BB rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)