JA Solar JAP6-72-315/4BB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-72-315/4BB is a 315.0 W STC (291.7 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.25% efficiency, 45.95 V Voc at 25 C, and 50.79 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
291.7 W
Voc @ 25C
45.95 V
Efficiency
16.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-72-315/4BB Compare Against Peer CEC Listings?

Engineering position of JA Solar JAP6-72-315/4BB (315.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-315 across 1,407 CEC Multi-c-Si solar modules.

Ranking #15,387 across 21,677 CEC solar panels (below all-CEC median; higher than 27.3% of peers), JA Solar JAP6-72-315/4BB operates as a compact residential or specialty off-grid module sitting 36.2 W above the 278.8 W Multi-c-Si median. Mid-range 45.95 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), 26 panels occupy 542 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does JA Solar JAP6-72-315/4BB Fall Across Listed CEC Models?

Plots JA Solar JAP6-72-315/4BB at 315.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-72-315/4BB (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-72-3: 315.0 W

What Dataset Percentiles Define JA Solar JAP6-72-315/4BB?

Benchmarks JA Solar JAP6-72-315/4BB on STC wattage, thermal PTC/STC retention, and 16.25 aperture conversion efficiency against CEC peers.

JA Solar JAP6-72-315/4BB Engineering BenchmarksPercentile comparison of JA Solar JAP6-72-315/4BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention92.6%Module Efficiency16.25%

What Do the Dataset Ranks Show for JA Solar JAP6-72-315/4BB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6-72-315/4BB by JA Solar.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,735

16.25% Aperture Efficiency

Power density 162.5 W/m2 (3.66 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.79 V at -10 C (558.7 V string) and 52.17 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 50.4 m2 (542 sq ft) producing 7,584 W PTC; NEC 690.8 OCPD floor is 14.01 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.95 * (1 + (-0.301/100) * (-10 - 25)) = 50.79 V | OCPD = 1.56 * 8.98 = 14.01 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-315/4BB: Voc=45.95 V, beta_Voc=-0.301%/C, Isc=8.98 A, STC=315.0 W, Area=1.938 m2.

Result: 11 panels max on 600 V (558.7 V); 26 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-72-315/4BB?

Laboratory test ratings recorded for JA Solar JAP6-72-315/4BB (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-315/4BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 291.7 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.95 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.19 V / 8.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.25% (1.938 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-72-315/4BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (542 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6-72-315/4BB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 417 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 542 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 668 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAP6-72-315/4BB under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAP6-72-315/4BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-72-305/4BB 305.0 W 282.3 W 45.37 V 36.88 V 15.73%
JA Solar JAP6-72-310/4BB 310.0 W 287.0 W 45.66 V 36.99 V 15.99%
JA Solar JAP6-72-315/4BB 315.0 W 291.7 W 45.95 V 37.19 V 16.25%
JA Solar JAP6-72-320/4BB 320.0 W 296.5 W 46.22 V 37.38 V 16.51%

How Many JA Solar JAP6-72-315/4BB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAP6-72-315/4BB (beta_Voc -0.301%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.95V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.17 V 11 panels 573.9 V 19 panels
-10 C (14 F) 50.79 V 11 panels 558.7 V 19 panels
0 C (32 F) 49.41 V 12 panels 592.9 V 20 panels
25 C (77 F STC) 45.95 V 13 panels 597.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-315/4BB?

Closest cross-brand CEC competitors to JA Solar JAP6-72-315/4BB matched near 315.0 W STC and 45.95 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-315.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-315
Boviet Solar Technology Co Ltd
315.0 W Tie (0 W) 46.1 V 16.23% 90.5%
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-315/4BB?

Evaluate JA Solar JAP6-72-315/4BB (315.0 W STC, 45.95 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-315/4BB reaches 52.17 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-315/4BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-72-315/4BB 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-315.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 291.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-315/4BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAP6-72-315/4BB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-72-315/4BB cold Voc rises from 45.95 V to 50.79 V (beta_Voc -0.301%/C), capping a 600 V string at 11 panels (558.7 V).

How much roof area does an 8 kW array of JA Solar JAP6-72-315/4BB need?

An 8 kW DC system uses 26 JA Solar JAP6-72-315/4BB modules (8,190 W STC / 7,584 W PTC), covering roughly 542 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does JA Solar JAP6-72-315/4BB compare against Boviet Solar Technology Co Ltd BVM6612M-315?

JA Solar JAP6-72-315/4BB outputs 315.0 W STC (45.95 V Voc, rank #15,387 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-315 delivers 315.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.