Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6-72-315/4BB/RE — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-72-315/4BB/RE is a 315.0 W STC (288.5 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.25% efficiency, 45.98 V Voc at 25 C, and 50.82 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
315.0 W
PTC Wattage
288.5 W
Voc @ 25C
45.98 V
Efficiency
16.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-72-315/4BB/RE Compare Against Peer CEC Listings?

Engineering position of JA Solar JAP6-72-315/4BB/RE (315.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-315 across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, JA Solar JAP6-72-315/4BB/RE pairs strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677) with 45.98 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,501 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-315 offers a 315.0 W alternative.

Where Does JA Solar JAP6-72-315/4BB/RE Fall Across Listed CEC Models?

Plots JA Solar JAP6-72-315/4BB/RE at 315.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-72-315/4BB/RE (315.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-72-3: 315.0 W

What Dataset Percentiles Define JA Solar JAP6-72-315/4BB/RE?

Benchmarks JA Solar JAP6-72-315/4BB/RE on STC wattage, thermal PTC/STC retention, and 16.25 aperture conversion efficiency against CEC peers.

JA Solar JAP6-72-315/4BB/RE Engineering BenchmarksPercentile comparison of JA Solar JAP6-72-315/4BB/RE wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage315.0 WPTC/STC Retention91.6%Module Efficiency16.25%

What Do the Dataset Ranks Show for JA Solar JAP6-72-315/4BB/RE?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6-72-315/4BB/RE by JA Solar.

Rank #15,387 / 21,677

315.0 W STC · Higher Than 27.3%

315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,735

16.25% Aperture Efficiency

Power density 162.5 W/m2 (3.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.82 V at -10 C (559.0 V string) and 52.21 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,190 W STC

Occupies 50.4 m2 (542 sq ft) producing 7,501 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.98 * (1 + (-0.301/100) * (-10 - 25)) = 50.82 V | OCPD = 1.56 * 8.89 = 13.87 A

Inputs from CEC Modules.csv for JA Solar JAP6-72-315/4BB/RE: Voc=45.98 V, beta_Voc=-0.301%/C, Isc=8.89 A, STC=315.0 W, Area=1.938 m2.

Result: 11 panels max on 600 V (559.0 V); 26 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-72-315/4BB/RE?

Laboratory test ratings recorded for JA Solar JAP6-72-315/4BB/RE (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-72-315/4BB/RE.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 315.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 288.5 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.89 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.73 V / 8.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.25% (1.938 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-72-315/4BB/RE Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (542 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6-72-315/4BB/RE.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.3 kW 417 sq ft $1,577 $2,666
8 kW Class 26 8.19 kW 542 sq ft $2,050 $3,466
10 kW Class 32 10.08 kW 668 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAP6-72-315/4BB/RE under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAP6-72-315/4BB/RE wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-72-305/4BB/RE 305.0 W 279.1 W 45.48 V 36.28 V 15.73%
JA Solar JAP6-72-310/4BB/RE 310.0 W 283.8 W 45.68 V 36.51 V 15.99%
JA Solar JAP6-72-315/4BB/RE 315.0 W 288.5 W 45.98 V 36.73 V 16.25%
JA Solar JAP6-72-320/4BB/RE 320.0 W 293.1 W 46.48 V 37.17 V 16.51%

How Many JA Solar JAP6-72-315/4BB/RE Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAP6-72-315/4BB/RE (beta_Voc -0.301%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.98V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.21 V 11 panels 574.3 V 19 panels
-10 C (14 F) 50.82 V 11 panels 559.0 V 19 panels
0 C (32 F) 49.44 V 12 panels 593.3 V 20 panels
25 C (77 F STC) 45.98 V 13 panels 597.7 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-315/4BB/RE?

Closest cross-brand CEC competitors to JA Solar JAP6-72-315/4BB/RE matched near 315.0 W STC and 45.98 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-315.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-315
Boviet Solar Technology Co Ltd
315.0 W Tie (0 W) 46.1 V 16.23% 90.5%
Centrosolar America EP72 315BW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
Centrosolar America EP72 315SW
Centrosolar America
315.0 W Tie (0 W) 45.75 V 16.38% 91.2%
GCL System Integration Technology Co Ltd GCL-P6/72315
GCL System Integration Technology Co Ltd
315.0 W Tie (0 W) 45.6 V 16.23% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-315/4BB/RE?

Evaluate JA Solar JAP6-72-315/4BB/RE (315.0 W STC, 45.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-315/4BB/RE reaches 52.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-315/4BB/RE carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-72-315/4BB/RE 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-315.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-72-315/4BB/RE by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-72-315/4BB/RE?

Multiplying JA Solar JAP6-72-315/4BB/RE's 8.89 A short-circuit current by 1.56 equals 13.87 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAP6-72-315/4BB/RE pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.82 V cold Voc at 14 F and handles 8.89 A Isc; string inverters cap JA Solar JAP6-72-315/4BB/RE at 11 panels on 600 V.

Is JA Solar JAP6-72-315/4BB/RE eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-72-315/4BB/RE rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.