JA Solar JAP6-72-315/4BB/RE is a 315.0 W STC (288.5 W PTC) Multi-c-Si solar module ranking #15,387 of 21,677 CEC listings (below all-CEC median; higher than 27.3% of peers). It delivers 16.25% efficiency, 45.98 V Voc at 25 C, and 50.82 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 315.0 W
- PTC Wattage
- 288.5 W
- Voc @ 25C
- 45.98 V
- Efficiency
- 16.25%
How Does JA Solar JAP6-72-315/4BB/RE Compare Against Peer CEC Listings?
Engineering position of JA Solar JAP6-72-315/4BB/RE (315.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-315 across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, JA Solar JAP6-72-315/4BB/RE pairs strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677) with 45.98 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,501 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-315 offers a 315.0 W alternative.
Where Does JA Solar JAP6-72-315/4BB/RE Fall Across Listed CEC Models?
Plots JA Solar JAP6-72-315/4BB/RE at 315.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAP6-72-315/4BB/RE?
Benchmarks JA Solar JAP6-72-315/4BB/RE on STC wattage, thermal PTC/STC retention, and 16.25 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAP6-72-315/4BB/RE?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAP6-72-315/4BB/RE by JA Solar.
315.0 W STC · Higher Than 27.3%
315.0 W STC (-70.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.25% Aperture Efficiency
Power density 162.5 W/m2 (3.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.82 V at -10 C (559.0 V string) and 52.21 V at -20 C (11 max).
26 Panels = 8,190 W STC
Occupies 50.4 m2 (542 sq ft) producing 7,501 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.98 * (1 + (-0.301/100) * (-10 - 25)) = 50.82 V | OCPD = 1.56 * 8.89 = 13.87 A
Inputs from CEC Modules.csv for JA Solar JAP6-72-315/4BB/RE: Voc=45.98 V, beta_Voc=-0.301%/C, Isc=8.89 A, STC=315.0 W, Area=1.938 m2.
Result: 11 panels max on 600 V (559.0 V); 26 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-72-315/4BB/RE?
Laboratory test ratings recorded for JA Solar JAP6-72-315/4BB/RE (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 315.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 288.5 W (91.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.98 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.73 V / 8.58 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.301 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.25% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-72-315/4BB/RE Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (542 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAP6-72-315/4BB/RE.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.3 kW | 417 sq ft | $1,577 | $2,666 |
| 8 kW Class | 26 | 8.19 kW | 542 sq ft | $2,050 | $3,466 |
| 10 kW Class | 32 | 10.08 kW | 668 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAP6-72-315/4BB/RE under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6-72-305/4BB/RE | 305.0 W | 279.1 W | 45.48 V | 36.28 V | 15.73% |
| JA Solar JAP6-72-310/4BB/RE | 310.0 W | 283.8 W | 45.68 V | 36.51 V | 15.99% |
| JA Solar JAP6-72-315/4BB/RE | 315.0 W | 288.5 W | 45.98 V | 36.73 V | 16.25% |
| JA Solar JAP6-72-320/4BB/RE | 320.0 W | 293.1 W | 46.48 V | 37.17 V | 16.51% |
How Many JA Solar JAP6-72-315/4BB/RE Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAP6-72-315/4BB/RE (beta_Voc -0.301%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.21 V | 11 panels | 574.3 V | 19 panels |
| -10 C (14 F) | 50.82 V | 11 panels | 559.0 V | 19 panels |
| 0 C (32 F) | 49.44 V | 12 panels | 593.3 V | 20 panels |
| 25 C (77 F STC) | 45.98 V | 13 panels | 597.7 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-315/4BB/RE?
Closest cross-brand CEC competitors to JA Solar JAP6-72-315/4BB/RE matched near 315.0 W STC and 45.98 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-315.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-315 Boviet Solar Technology Co Ltd |
315.0 W | Tie (0 W) | 46.1 V | 16.23% | 90.5% |
| Centrosolar America EP72 315BW Centrosolar America |
315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| Centrosolar America EP72 315SW Centrosolar America |
315.0 W | Tie (0 W) | 45.75 V | 16.38% | 91.2% |
| GCL System Integration Technology Co Ltd GCL-P6/72315 GCL System Integration Technology Co Ltd |
315.0 W | Tie (0 W) | 45.6 V | 16.23% | 90.5% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-315/4BB/RE?
Evaluate JA Solar JAP6-72-315/4BB/RE (315.0 W STC, 45.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-315/4BB/RE reaches 52.21 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-315/4BB/RE carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-72-315/4BB/RE 8 kW Residential Fit
Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-315.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 288.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-72-315/4BB/RE by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-72-315/4BB/RE?
Multiplying JA Solar JAP6-72-315/4BB/RE's 8.89 A short-circuit current by 1.56 equals 13.87 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAP6-72-315/4BB/RE pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.82 V cold Voc at 14 F and handles 8.89 A Isc; string inverters cap JA Solar JAP6-72-315/4BB/RE at 11 panels on 600 V.
Is JA Solar JAP6-72-315/4BB/RE eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-72-315/4BB/RE rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)