Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6-60-265/4BB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-265/4BB is a 265.0 W STC (245.4 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.21% efficiency, 38.05 V Voc at 25 C, and 42.06 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
245.4 W
Voc @ 25C
38.05 V
Efficiency
16.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-265/4BB Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-60-265/4BB handles rooftop heat (245.4 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAP6-60-265/4BB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 162.1 W/m2 (3.70 percentage points below 19.91% CEC median). Compared against Centrosolar America TM6 265xx (265.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Lower 38.05 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.16 A overcurrent floor served by a 15 A breaker.

Where Does JA Solar JAP6-60-265/4BB Fall Across Listed CEC Models?

Where JA Solar JAP6-60-265/4BB (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-265/4BB (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 265.0 W

What Dataset Percentiles Define JA Solar JAP6-60-265/4BB?

Percentile placement of JA Solar JAP6-60-265/4BB across power density (162.1 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAP6-60-265/4BB Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-265/4BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention92.6%Module Efficiency16.21%

What Do the Dataset Ranks Show for JA Solar JAP6-60-265/4BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-265/4BB specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,855

16.21% Aperture Efficiency

Power density 162.1 W/m2 (3.70 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.06 V at -10 C (588.8 V string) and 43.2 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,607 W PTC; NEC 690.8 OCPD floor is 14.16 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.05 * (1 + (-0.301/100) * (-10 - 25)) = 42.06 V | OCPD = 1.56 * 9.08 = 14.16 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-265/4BB: Voc=38.05 V, beta_Voc=-0.301%/C, Isc=9.08 A, STC=265.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (588.8 V); 31 panels for 8 kW (546 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-265/4BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-265/4BB.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-265/4BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 245.4 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.05 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.08 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.02 V / 8.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.21% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-265/4BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-265/4BB (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 405 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 546 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 669 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-60-265/4BB architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the JA Solar JAP6-60-265/4BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-60-255/4BB 255.0 W 236.0 W 37.61 V 30.59 V 15.59%
JA Solar JAP6-60-260/4BB 260.0 W 240.7 W 37.84 V 30.81 V 15.9%
JA Solar JAP6-60-265/4BB 265.0 W 245.4 W 38.05 V 31.02 V 16.21%
JA Solar JAP6-60-270/4BB 270.0 W 250.2 W 38.27 V 31.23 V 16.51%

How Many JA Solar JAP6-60-265/4BB Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-60-265/4BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.05V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.2 V 13 panels 561.6 V 23 panels
-10 C (14 F) 42.06 V 14 panels 588.8 V 23 panels
0 C (32 F) 40.91 V 14 panels 572.7 V 24 panels
25 C (77 F STC) 38.05 V 15 panels 570.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-265/4BB?

Alternative CEC solar modules from competing brands near JA Solar JAP6-60-265/4BB (265.0 W), including Centrosolar America TM6 265xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM6 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
Centrosolar America TM6S 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
GCL System Integration Technology Co Ltd GCL-P6/60265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.29% 90.5%
GCL System Integration Technology Co Ltd GCL-P6/60B265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.26% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-265/4BB?

Evaluate JA Solar JAP6-60-265/4BB (265.0 W STC, 38.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-265/4BB reaches 43.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-265/4BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-265/4BB 8 kW Residential Fit

Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 265xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 245.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-265/4BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-60-265/4BB?

Multiplying JA Solar JAP6-60-265/4BB's 9.08 A short-circuit current by 1.56 equals 14.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAP6-60-265/4BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.06 V cold Voc at 14 F and handles 9.08 A Isc; string inverters cap JA Solar JAP6-60-265/4BB at 14 panels on 600 V.

Is JA Solar JAP6-60-265/4BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-60-265/4BB rely on utility bill offset (~$2,055/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.