Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6-60-265/4BB/RE — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-265/4BB/RE is a 265.0 W STC (242.7 W PTC) Multi-c-Si solar module ranking #18,880 of 21,677 CEC listings (below all-CEC median; higher than 11.7% of peers). It delivers 16.21% efficiency, 38.14 V Voc at 25 C, and 42.16 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
265.0 W
PTC Wattage
242.7 W
Voc @ 25C
38.14 V
Efficiency
16.21%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-265/4BB/RE Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-60-265/4BB/RE handles rooftop heat (242.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, JA Solar JAP6-60-265/4BB/RE exhibits 9.1 A short-circuit current, requiring a 14.2 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,880 of 21,677 (13.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.7 m2 for an 8 kW system (38 panels for 10 kW). Lower 38.14 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does JA Solar JAP6-60-265/4BB/RE Fall Across Listed CEC Models?

Where JA Solar JAP6-60-265/4BB/RE (265.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-265/4BB/RE (265.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 265.0 W

What Dataset Percentiles Define JA Solar JAP6-60-265/4BB/RE?

Percentile placement of JA Solar JAP6-60-265/4BB/RE across power density (162.1 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAP6-60-265/4BB/RE Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-265/4BB/RE wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage265.0 WPTC/STC Retention91.6%Module Efficiency16.21%

What Do the Dataset Ranks Show for JA Solar JAP6-60-265/4BB/RE?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-265/4BB/RE specifications.

Rank #18,880 / 21,677

265.0 W STC · Higher Than 11.7%

265.0 W STC (-120.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,855

16.21% Aperture Efficiency

Power density 162.1 W/m2 (3.70 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.16 V at -10 C (590.2 V string) and 43.31 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,215 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,524 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.14 * (1 + (-0.301/100) * (-10 - 25)) = 42.16 V | OCPD = 1.56 * 9.1 = 14.2 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-265/4BB/RE: Voc=38.14 V, beta_Voc=-0.301%/C, Isc=9.1 A, STC=265.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (590.2 V); 31 panels for 8 kW (546 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-265/4BB/RE?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-265/4BB/RE.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-265/4BB/RE.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 265.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 242.7 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.14 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.1 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.89 V / 8.58 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.21% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-265/4BB/RE Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-265/4BB/RE (265.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.09 kW 405 sq ft $1,524 $2,577
8 kW Class 31 8.21 kW 546 sq ft $2,055 $3,475
10 kW Class 38 10.07 kW 669 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAP6-60-265/4BB/RE architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the JA Solar JAP6-60-265/4BB/RE wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-60-260/4BB/RE 260.0 W 238.0 W 37.98 V 30.55 V 15.9%
JA Solar JAP6-60-265/4BB/RE 265.0 W 242.7 W 38.14 V 30.89 V 16.21%
JA Solar JAP6-60-270/4BB/RE 270.0 W 247.3 W 38.3 V 31.21 V 16.51%

How Many JA Solar JAP6-60-265/4BB/RE Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-60-265/4BB/RE from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.14V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.31 V 13 panels 563.0 V 23 panels
-10 C (14 F) 42.16 V 14 panels 590.2 V 23 panels
0 C (32 F) 41.01 V 14 panels 574.1 V 24 panels
25 C (77 F STC) 38.14 V 15 panels 572.1 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-265/4BB/RE?

Alternative CEC solar modules from competing brands near JA Solar JAP6-60-265/4BB/RE (265.0 W), including GCL System Integration Technology Co Ltd GCL-P6/60265.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.29% 90.5%
GCL System Integration Technology Co Ltd GCL-P6/60B265
GCL System Integration Technology Co Ltd
265.0 W Tie (0 W) 38.1 V 16.26% 90.2%
Boviet Solar Technology Co Ltd BVM6610M-265
Boviet Solar Technology Co Ltd
265.0 W Tie (0 W) 38.2 V 16.29% 91.6%
Centrosolar America TM6 265xx
Centrosolar America
265.0 W Tie (0 W) 38.0 V 16.22% 90.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-265/4BB/RE?

Evaluate JA Solar JAP6-60-265/4BB/RE (265.0 W STC, 38.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-265/4BB/RE reaches 43.31 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-265/4BB/RE carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-265/4BB/RE 8 kW Residential Fit

Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,055/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60265.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-265/4BB/RE by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is JA Solar JAP6-60-265/4BB/RE PTC wattage (242.7 W) lower than STC (265.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 242.7 W PTC (91.6% retention) across JA Solar JAP6-60-265/4BB/RE's 1.635 m2 aperture.

Who should skip JA Solar JAP6-60-265/4BB/RE on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 JA Solar JAP6-60-265/4BB/RE panels (546 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-P6/60265.

What is the 1,000 V commercial string limit for JA Solar JAP6-60-265/4BB/RE?

On 1,000 V commercial inverters at -10 C (42.16 V cold Voc), JA Solar JAP6-60-265/4BB/RE fits up to 23 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.