Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAP6-60-260/3BB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-260/3BB is a 260.0 W STC (234.7 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.9% efficiency, 37.98 V Voc at 25 C, and 42.1 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
234.7 W
Voc @ 25C
37.98 V
Efficiency
15.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-260/3BB Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAP6-60-260/3BB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 260.0 W STC and 234.7 W PTC, JA Solar JAP6-60-260/3BB sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 159.0 W/m2 (4.01 percentage points below 19.91% CEC median). Lower 37.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W rates 260.0 W.

Where Does JA Solar JAP6-60-260/3BB Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAP6-60-260/3BB (260.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-260/3BB (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 260.0 W

What Dataset Percentiles Define JA Solar JAP6-60-260/3BB?

Dataset percentiles tracking JA Solar JAP6-60-260/3BB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAP6-60-260/3BB Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-260/3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention90.3%Module Efficiency15.9%

What Do the Dataset Ranks Show for JA Solar JAP6-60-260/3BB?

Benchmark highlights for JA Solar JAP6-60-260/3BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,312

15.9% Aperture Efficiency

Power density 159.0 W/m2 (4.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.1 V at -10 C (589.4 V string) and 43.28 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,276 W PTC; NEC 690.8 OCPD floor is 14.1 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.98 * (1 + (-0.31/100) * (-10 - 25)) = 42.1 V | OCPD = 1.56 * 9.04 = 14.1 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-260/3BB: Voc=37.98 V, beta_Voc=-0.31%/C, Isc=9.04 A, STC=260.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (589.4 V); 31 panels for 8 kW (546 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-260/3BB?

Official CEC datasheet figures for JA Solar JAP6-60-260/3BB (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-260/3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 234.7 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.98 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.04 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.63 V / 8.49 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.9% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-260/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAP6-60-260/3BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 422 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 546 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 686 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAP6-60-260/3BB mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the JA Solar JAP6-60-260/3BB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAP6-60-250/3BB 250.0 W 222.9 W 37.54 V 29.98 V 15.29%
JA Solar JAP6-60-255/3BB 255.0 W 230.1 W 37.82 V 30.29 V 15.59%
JA Solar JAP6-60-260/3BB 260.0 W 234.7 W 37.98 V 30.63 V 15.9%
JA Solar JAP6-60-265/3BB 265.0 W 239.4 W 38.14 V 30.96 V 16.21%
JA Solar JAP6-60-270/3BB 270.0 W 244.0 W 38.3 V 31.29 V 16.51%

How Many JA Solar JAP6-60-260/3BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAP6-60-260/3BB (42.1 V at 14 F).

Computed from Voc=37.98V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.28 V 13 panels 562.6 V 23 panels
-10 C (14 F) 42.1 V 14 panels 589.4 V 23 panels
0 C (32 F) 40.92 V 14 panels 572.9 V 24 panels
25 C (77 F STC) 37.98 V 15 panels 569.7 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-260/3BB?

Competing CEC solar panels closest to JA Solar JAP6-60-260/3BB in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
260.0 W Tie (0 W) 38.0 V 16.01% 88.5%
Chinaland Solar Energy HSE260-60M
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 16.01% 90.5%
Chinaland Solar Energy HSE260-60M-B
Chinaland Solar Energy
260.0 W Tie (0 W) 38.0 V 15.21% 90.4%
GermanSolar USA GSP6-60-260W
GermanSolar USA
260.0 W Tie (0 W) 38.0 V 15.98% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-260/3BB?

Evaluate JA Solar JAP6-60-260/3BB (260.0 W STC, 37.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-260/3BB reaches 43.28 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-260/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-260/3BB 8 kW Residential Fit

Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 234.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-260/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAP6-60-260/3BB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAP6-60-260/3BB cold Voc rises from 37.98 V to 42.1 V (beta_Voc -0.31%/C), capping a 600 V string at 14 panels (589.4 V).

How much roof area does an 8 kW array of JA Solar JAP6-60-260/3BB need?

An 8 kW DC system uses 31 JA Solar JAP6-60-260/3BB modules (8,060 W STC / 7,276 W PTC), covering roughly 546 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does JA Solar JAP6-60-260/3BB compare against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W?

JA Solar JAP6-60-260/3BB outputs 260.0 W STC (37.98 V Voc, rank #19,146 of 21,677), while Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.