JA Solar JAM78S10-455/MR is a 455.0 W STC (427.9 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.56% efficiency, 53.87 V Voc at 25 C, and 58.85 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 427.9 W
- Voc @ 25C
- 53.87 V
- Efficiency
- 21.56%
How Does JA Solar JAM78S10-455/MR Compare Against Peer CEC Listings?
Engineering position of JA Solar JAM78S10-455/MR (455.0 W STC) vs. CSI Solar Co Ltd CS3Y-460P across 5,889 CEC Mono-c-Si solar modules.
Ranking #5,417 across 21,677 CEC solar panels (top 26.2%; higher than 73.8% of peers), JA Solar JAM78S10-455/MR operates as a modern high-density residential and light-commercial module sitting 45.0 W above the 410.0 W Mono-c-Si median. Higher 53.87 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), 18 panels occupy 409 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAM78S10-455/MR Fall Across Listed CEC Models?
Plots JA Solar JAM78S10-455/MR at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM78S10-455/MR?
Benchmarks JA Solar JAM78S10-455/MR on STC wattage, thermal PTC/STC retention, and 21.56 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for JA Solar JAM78S10-455/MR?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM78S10-455/MR by JA Solar.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.56% Aperture Efficiency
Power density 215.6 W/m2 (1.65 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.85 V at -10 C (588.5 V string) and 60.27 V at -20 C (9 max).
18 Panels = 8,190 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,702 W PTC; NEC 690.8 OCPD floor is 16.47 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.87 * (1 + (-0.264/100) * (-10 - 25)) = 58.85 V | OCPD = 1.56 * 10.56 = 16.47 A
Inputs from CEC Modules.csv for JA Solar JAM78S10-455/MR: Voc=53.87 V, beta_Voc=-0.264%/C, Isc=10.56 A, STC=455.0 W, Area=2.11 m2.
Result: 10 panels max on 600 V (588.5 V); 18 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for JA Solar JAM78S10-455/MR?
Laboratory test ratings recorded for JA Solar JAM78S10-455/MR (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 427.9 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.87 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.83 V / 9.93 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.264 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.56% (2.11 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM78S10-455/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (409 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM78S10-455/MR.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 318 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 409 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 500 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Sibling wattage bins and frame colors grouped with JA Solar JAM78S10-455/MR under JA Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM78S10-450/MR | 450.0 W | 423.1 W | 53.58 V | 45.51 V | 21.33% |
| JA Solar JAM78S10-455/MR | 455.0 W | 427.9 W | 53.87 V | 45.83 V | 21.56% |
How Many JA Solar JAM78S10-455/MR Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for JA Solar JAM78S10-455/MR (beta_Voc -0.264%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 60.27 V | 9 panels | 542.4 V | 16 panels |
| -10 C (14 F) | 58.85 V | 10 panels | 588.5 V | 16 panels |
| 0 C (32 F) | 57.43 V | 10 panels | 574.3 V | 17 panels |
| 25 C (77 F STC) | 53.87 V | 11 panels | 592.6 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM78S10-455/MR?
Closest cross-brand CEC competitors to JA Solar JAM78S10-455/MR matched near 455.0 W STC and 53.87 V Voc, led by CSI Solar Co Ltd CS3Y-460P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | +5.0 W | 52.0 V | 20.09% | 93.1% |
| Heliene 144HC-460 Heliene |
460.0 W | +5.0 W | 51.26 V | 20.81% | 92.4% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI HD HYUNDAI ENERGY SOLUTIONS CO LTD |
455.0 W | Tie (0 W) | 50.0 V | 20.97% | 93.9% |
| HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455YI HD HYUNDAI ENERGY SOLUTIONS CO LTD |
455.0 W | Tie (0 W) | 50.0 V | 20.97% | 93.8% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM78S10-455/MR?
Evaluate JA Solar JAM78S10-455/MR (455.0 W STC, 53.87 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM78S10-455/MR reaches 60.27 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM78S10-455/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM78S10-455/MR 8 kW Residential Fit
Needs 18 modules (409 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-460P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM78S10-455/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM78S10-455/MR panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM78S10-455/MR cold Voc rises from 53.87 V to 58.85 V (beta_Voc -0.264%/C), capping a 600 V string at 10 panels (588.5 V).
How much roof area does an 8 kW array of JA Solar JAM78S10-455/MR need?
An 8 kW DC system uses 18 JA Solar JAM78S10-455/MR modules (8,190 W STC / 7,702 W PTC), covering roughly 409 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does JA Solar JAM78S10-455/MR compare against CSI Solar Co Ltd CS3Y-460P?
JA Solar JAM78S10-455/MR outputs 455.0 W STC (53.87 V Voc, rank #5,417 of 21,677), while CSI Solar Co Ltd CS3Y-460P delivers 460.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)