JA Solar JAM78D30-590/MB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM78D30-590/MB is a 590.0 W STC (553.2 W PTC) Mono-c-Si solar module ranking #1,597 of 21,677 CEC listings (top 8.1%; higher than 91.9% of peers). It delivers 21.69% efficiency, 53.3 V Voc at 25 C, and 57.91 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
590.0 W
PTC Wattage
553.2 W
Voc @ 25C
53.3 V
Efficiency
21.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM78D30-590/MB Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM78D30-590/MB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 590.0 W STC and 553.2 W PTC, JA Solar JAM78D30-590/MB sits +205.0 W vs all-CEC median (top 8.1%; higher than 91.9% of peers) among 21,677 listed modules. Power density reaches 216.9 W/m2 (1.78 percentage points above 19.91% CEC median). Higher 53.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer Elin Energy (Sirius PV) ELNSM78M-HC-BF-590 rates 590.0 W.

Where Does JA Solar JAM78D30-590/MB Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM78D30-590/MB (590.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM78D30-590/MB (590.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM78D30-: 590.0 W

What Dataset Percentiles Define JA Solar JAM78D30-590/MB?

Dataset percentiles tracking JA Solar JAM78D30-590/MB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAM78D30-590/MB Engineering BenchmarksPercentile comparison of JA Solar JAM78D30-590/MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage590.0 WPTC/STC Retention93.8%Module Efficiency21.69%

What Do the Dataset Ranks Show for JA Solar JAM78D30-590/MB?

Benchmark highlights for JA Solar JAM78D30-590/MB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #1,597 / 21,677

Top 8.1% STC Output

590.0 W STC (+205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,894

21.69% Aperture Efficiency

Power density 216.9 W/m2 (1.78 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.91 V at -10 C (579.1 V string) and 59.22 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,260 W STC

Occupies 38.1 m2 (410 sq ft) producing 7,745 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.3 * (1 + (-0.247/100) * (-10 - 25)) = 57.91 V | OCPD = 1.56 * 13.93 = 21.73 A

Inputs from CEC Modules.csv for JA Solar JAM78D30-590/MB: Voc=53.3 V, beta_Voc=-0.247%/C, Isc=13.93 A, STC=590.0 W, Area=2.72 m2.

Result: 10 panels max on 600 V (579.1 V); 14 panels for 8 kW (410 sq ft).

What Are the Published CEC Specifications for JA Solar JAM78D30-590/MB?

Official CEC datasheet figures for JA Solar JAM78D30-590/MB (Mono-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM78D30-590/MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 590.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 553.2 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.93 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.8 V / 13.17 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.69% (2.72 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM78D30-590/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM78D30-590/MB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.49 kW 322 sq ft $1,624 $2,747
8 kW Class 14 8.26 kW 410 sq ft $2,067 $3,496
10 kW Class 17 10.03 kW 498 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM78D30-590/MB mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the JA Solar JAM78D30-590/MB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM78D30-580/MB 580.0 W 543.5 W 53.11 V 44.35 V 21.32%
JA Solar JAM78D30-585/MB 585.0 W 548.3 W 53.2 V 44.56 V 21.51%
JA Solar JAM78D30-590/MB 590.0 W 553.2 W 53.3 V 44.8 V 21.69%
JA Solar JAM78D30-595/MB 595.0 W 558.0 W 53.4 V 45.05 V 21.88%

How Many JA Solar JAM78D30-590/MB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM78D30-590/MB (57.91 V at 14 F).

Computed from Voc=53.3V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.22 V 10 panels 592.2 V 16 panels
-10 C (14 F) 57.91 V 10 panels 579.1 V 17 panels
0 C (32 F) 56.59 V 10 panels 565.9 V 17 panels
25 C (77 F STC) 53.3 V 11 panels 586.3 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM78D30-590/MB?

Competing CEC solar panels closest to JA Solar JAM78D30-590/MB in nameplate wattage and Voc, starting with Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Elin Energy (Sirius PV) ELNSM78M-HC-BF-590
Elin Energy (Sirius PV)
590.0 W Tie (0 W) 53.83 V 21.3% 94.4%
Aptos Solar Technology LLC DNA-144-BFN10-590W-DG
Aptos Solar Technology LLC
590.0 W Tie (0 W) 52.4 V 22.87% 95.0%
BLUESUN GROUP LIMITED BSM590M10-72HNH
BLUESUN GROUP LIMITED
590.0 W Tie (0 W) 52.4 V 22.87% 95.0%
FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585
FS GREEN ENERGIES PRIVATE LIMITED
585.0 W -5.0 W 53.1 V 22.85% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM78D30-590/MB?

Evaluate JA Solar JAM78D30-590/MB (590.0 W STC, 53.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM78D30-590/MB reaches 59.22 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 410 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM78D30-590/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM78D30-590/MB 8 kW Residential Fit

Needs 14 modules (410 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Elin Energy (Sirius PV) ELNSM78M-HC-BF-590.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 553.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM78D30-590/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM78D30-590/MB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM78D30-590/MB cold Voc rises from 53.3 V to 57.91 V (beta_Voc -0.247%/C), capping a 600 V string at 10 panels (579.1 V).

How much roof area does an 8 kW array of JA Solar JAM78D30-590/MB need?

An 8 kW DC system uses 14 JA Solar JAM78D30-590/MB modules (8,260 W STC / 7,745 W PTC), covering roughly 410 sq ft and saving ~$2,067/yr at 18.54 c/kWh.

How does JA Solar JAM78D30-590/MB compare against Elin Energy (Sirius PV) ELNSM78M-HC-BF-590?

JA Solar JAM78D30-590/MB outputs 590.0 W STC (53.3 V Voc, rank #1,597 of 21,677), while Elin Energy (Sirius PV) ELNSM78M-HC-BF-590 delivers 590.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.