Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAM78D10-440/MB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM78D10-440/MB is a 440.0 W STC (411.8 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.47% efficiency, 53.01 V Voc at 25 C, and 57.89 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
411.8 W
Voc @ 25C
53.01 V
Efficiency
20.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM78D10-440/MB Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM78D10-440/MB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 440.0 W STC and 411.8 W PTC, JA Solar JAM78D10-440/MB sits +55.0 W vs all-CEC median (top 31.6%; higher than 68.4% of peers) among 21,677 listed modules. Power density reaches 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). Higher 53.01 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer CSI Solar Co Ltd CS3Y-440PB-AG rates 440.0 W.

Where Does JA Solar JAM78D10-440/MB Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM78D10-440/MB (440.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM78D10-440/MB (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM78D10-: 440.0 W

What Dataset Percentiles Define JA Solar JAM78D10-440/MB?

Dataset percentiles tracking JA Solar JAM78D10-440/MB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAM78D10-440/MB Engineering BenchmarksPercentile comparison of JA Solar JAM78D10-440/MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention93.6%Module Efficiency20.47%

What Do the Dataset Ranks Show for JA Solar JAM78D10-440/MB?

Benchmark highlights for JA Solar JAM78D10-440/MB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,713

20.47% Aperture Efficiency

Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.89 V at -10 C (578.9 V string) and 59.28 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,824 W PTC; NEC 690.8 OCPD floor is 16.18 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.01 * (1 + (-0.263/100) * (-10 - 25)) = 57.89 V | OCPD = 1.56 * 10.37 = 16.18 A

Inputs from CEC Modules.csv for JA Solar JAM78D10-440/MB: Voc=53.01 V, beta_Voc=-0.263%/C, Isc=10.37 A, STC=440.0 W, Area=2.15 m2.

Result: 10 panels max on 600 V (578.9 V); 19 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for JA Solar JAM78D10-440/MB?

Official CEC datasheet figures for JA Solar JAM78D10-440/MB (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM78D10-440/MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 411.8 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.01 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.68 V / 9.85 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.47% (2.15 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM78D10-440/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM78D10-440/MB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 324 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 440 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 532 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM78D10-440/MB mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the JA Solar JAM78D10-440/MB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM78D10-435/MB 435.0 W 407.0 W 52.74 V 44.31 V 20.23%
JA Solar JAM78D10-440/MB 440.0 W 411.8 W 53.01 V 44.68 V 20.47%
JA Solar JAM78D10-445/MB 445.0 W 416.6 W 53.29 V 44.96 V 20.7%

How Many JA Solar JAM78D10-440/MB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM78D10-440/MB (57.89 V at 14 F).

Computed from Voc=53.01V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 59.28 V 10 panels 592.8 V 16 panels
-10 C (14 F) 57.89 V 10 panels 578.9 V 17 panels
0 C (32 F) 56.5 V 10 panels 565.0 V 17 panels
25 C (77 F STC) 53.01 V 11 panels 583.1 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM78D10-440/MB?

Competing CEC solar panels closest to JA Solar JAM78D10-440/MB in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3Y-440PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-440PB-AG
CSI Solar Co Ltd
440.0 W Tie (0 W) 51.2 V 19.13% 93.7%
Bluesun Solar CoLtd BSM440M-72HBD
Bluesun Solar CoLtd
440.0 W Tie (0 W) 50.0 V 20.28% 92.7%
Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi
Bright Spot Solar LLC
445.0 W +5.0 W 50.6 V 20.14% 93.5%
Aptos Solar Technology LLC DNA-144-BF26-435W
Aptos Solar Technology LLC
435.0 W -5.0 W 49.38 V 20.71% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM78D10-440/MB?

Evaluate JA Solar JAM78D10-440/MB (440.0 W STC, 53.01 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM78D10-440/MB reaches 59.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 440 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM78D10-440/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM78D10-440/MB 8 kW Residential Fit

Needs 19 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-440PB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 411.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM78D10-440/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM78D10-440/MB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM78D10-440/MB cold Voc rises from 53.01 V to 57.89 V (beta_Voc -0.263%/C), capping a 600 V string at 10 panels (578.9 V).

How much roof area does an 8 kW array of JA Solar JAM78D10-440/MB need?

An 8 kW DC system uses 19 JA Solar JAM78D10-440/MB modules (8,360 W STC / 7,824 W PTC), covering roughly 440 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does JA Solar JAM78D10-440/MB compare against CSI Solar Co Ltd CS3Y-440PB-AG?

JA Solar JAM78D10-440/MB outputs 440.0 W STC (53.01 V Voc, rank #6,418 of 21,677), while CSI Solar Co Ltd CS3Y-440PB-AG delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls