JA Solar JAM72S10-395/MR is a 395.0 W STC (369.7 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 49.3 V Voc at 25 C, and 53.91 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 369.7 W
- Voc @ 25C
- 49.3 V
- Efficiency
- 20.26%
How Does JA Solar JAM72S10-395/MR Compare Against Peer CEC Listings?
How JA Solar JA Solar JAM72S10-395/MR handles rooftop heat (369.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, JA Solar JAM72S10-395/MR exhibits 10.27 A short-circuit current, requiring a 16.02 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.9 m2 for an 8 kW system (26 panels for 10 kW). Higher 49.3 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does JA Solar JAM72S10-395/MR Fall Across Listed CEC Models?
Where JA Solar JAM72S10-395/MR (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAM72S10-395/MR?
Percentile placement of JA Solar JAM72S10-395/MR across power density (202.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAM72S10-395/MR?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM72S10-395/MR specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.26% Aperture Efficiency
Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.91 V at -10 C (593.0 V string) and 55.22 V at -20 C (10 max).
21 Panels = 8,295 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,764 W PTC; NEC 690.8 OCPD floor is 16.02 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.3 * (1 + (-0.267/100) * (-10 - 25)) = 53.91 V | OCPD = 1.56 * 10.27 = 16.02 A
Inputs from CEC Modules.csv for JA Solar JAM72S10-395/MR: Voc=49.3 V, beta_Voc=-0.267%/C, Isc=10.27 A, STC=395.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (593.0 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72S10-395/MR?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM72S10-395/MR.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 369.7 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.06 V / 9.62 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.26% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM72S10-395/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM72S10-395/MR (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |
How Many JA Solar JAM72S10-395/MR Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAM72S10-395/MR from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.22 V | 10 panels | 552.2 V | 18 panels |
| -10 C (14 F) | 53.91 V | 11 panels | 593.0 V | 18 panels |
| 0 C (32 F) | 52.59 V | 11 panels | 578.5 V | 19 panels |
| 25 C (77 F STC) | 49.3 V | 12 panels | 591.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S10-395/MR?
Alternative CEC solar modules from competing brands near JA Solar JAM72S10-395/MR (395.0 W), including ELITE Solar ET-M672BH395WW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-M672BH395WW ELITE Solar |
395.0 W | Tie (0 W) | 49.5 V | 19.85% | 93.3% |
| ELITE Solar ET-M672BH395GL ELITE Solar |
395.0 W | Tie (0 W) | 49.6 V | 19.36% | 93.2% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S10-395/MR?
Evaluate JA Solar JAM72S10-395/MR (395.0 W STC, 49.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S10-395/MR reaches 55.22 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S10-395/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72S10-395/MR 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M672BH395WW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72S10-395/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAM72S10-395/MR PTC wattage (369.7 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 369.7 W PTC (93.6% retention) across JA Solar JAM72S10-395/MR's 1.95 m2 aperture.
Who should skip JA Solar JAM72S10-395/MR on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 JA Solar JAM72S10-395/MR panels (441 sq ft) leave unusable roof gaps vs. ELITE Solar ET-M672BH395WW.
What is the 1,000 V commercial string limit for JA Solar JAM72S10-395/MR?
On 1,000 V commercial inverters at -10 C (53.91 V cold Voc), JA Solar JAM72S10-395/MR fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAM72S10-395/MR.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)