JA Solar JAM72S09-400/PR is a 400.0 W STC (373.3 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.62% efficiency, 49.92 V Voc at 25 C, and 54.6 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 373.3 W
- Voc @ 25C
- 49.92 V
- Efficiency
- 20.62%
How Does JA Solar JAM72S09-400/PR Compare Against Peer CEC Listings?
Solar engineering breakdown for JA Solar JAM72S09-400/PR: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 400.0 W STC and 373.3 W PTC, JA Solar JAM72S09-400/PR sits +15.0 W vs all-CEC median (top 45.5%; higher than 54.5% of peers) among 21,677 listed modules. Power density reaches 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). Higher 49.92 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-400-H rates 400.0 W.
Where Does JA Solar JAM72S09-400/PR Fall Across Listed CEC Models?
Distribution marker showing JA Solar JAM72S09-400/PR (400.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define JA Solar JAM72S09-400/PR?
Dataset percentiles tracking JA Solar JAM72S09-400/PR power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for JA Solar JAM72S09-400/PR?
Benchmark highlights for JA Solar JAM72S09-400/PR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.62% Aperture Efficiency
Power density 206.2 W/m2 (0.71 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.6 V at -10 C (546.0 V string) and 55.94 V at -20 C (10 max).
20 Panels = 8,000 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,466 W PTC; NEC 690.8 OCPD floor is 16.11 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.92 * (1 + (-0.268/100) * (-10 - 25)) = 54.6 V | OCPD = 1.56 * 10.33 = 16.11 A
Inputs from CEC Modules.csv for JA Solar JAM72S09-400/PR: Voc=49.92 V, beta_Voc=-0.268%/C, Isc=10.33 A, STC=400.0 W, Area=1.94 m2.
Result: 10 panels max on 600 V (546.0 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72S09-400/PR?
Official CEC datasheet figures for JA Solar JAM72S09-400/PR (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 373.3 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.92 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.78 V / 9.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.62% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM72S09-400/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many JA Solar JAM72S09-400/PR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 313 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 418 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 522 sq ft | $2,503 | $4,232 |
How Many JA Solar JAM72S09-400/PR Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM72S09-400/PR (54.6 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.94 V | 10 panels | 559.4 V | 17 panels |
| -10 C (14 F) | 54.6 V | 10 panels | 546.0 V | 18 panels |
| 0 C (32 F) | 53.26 V | 11 panels | 585.9 V | 18 panels |
| 25 C (77 F STC) | 49.92 V | 12 panels | 599.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S09-400/PR?
Competing CEC solar panels closest to JA Solar JAM72S09-400/PR in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-400-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | +5.0 W | 49.45 V | 20.35% | 93.3% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC Boviet Solar Technology Co Ltd |
405.0 W | +5.0 W | 49.45 V | 19.95% | 93.6% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S09-400/PR?
Evaluate JA Solar JAM72S09-400/PR (400.0 W STC, 49.92 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S09-400/PR reaches 55.94 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S09-400/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72S09-400/PR 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 373.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72S09-400/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many JA Solar JAM72S09-400/PR panels fit on a 600 V winter solar string?
At -10 C (14 F), JA Solar JAM72S09-400/PR cold Voc rises from 49.92 V to 54.6 V (beta_Voc -0.268%/C), capping a 600 V string at 10 panels (546.0 V).
How much roof area does an 8 kW array of JA Solar JAM72S09-400/PR need?
An 8 kW DC system uses 20 JA Solar JAM72S09-400/PR modules (8,000 W STC / 7,466 W PTC), covering roughly 418 sq ft and saving ~$2,002/yr at 18.54 c/kWh.
How does JA Solar JAM72S09-400/PR compare against Boviet Solar Technology Co Ltd BVM6612M-400-H?
JA Solar JAM72S09-400/PR outputs 400.0 W STC (49.92 V Voc, rank #9,407 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-400-H delivers 400.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)