JA Solar JAM72S09-385/PR is a 385.0 W STC (359.0 W PTC) Mono-c-Si solar module ranking #10,723 of 21,677 CEC listings (at all-CEC median; higher than 49.1% of peers). It delivers 19.85% efficiency, 49.04 V Voc at 25 C, and 53.64 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 385.0 W
- PTC Wattage
- 359.0 W
- Voc @ 25C
- 49.04 V
- Efficiency
- 19.85%
How Does JA Solar JAM72S09-385/PR Compare Against Peer CEC Listings?
Solar engineering breakdown for JA Solar JAM72S09-385/PR: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from JA Solar and peers, JA Solar JAM72S09-385/PR stands 25.0 W below the 410.0 W Mono-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,542-$2,505/yr in baseline US bill offset. Higher 49.04 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does JA Solar JAM72S09-385/PR Fall Across Listed CEC Models?
Distribution marker showing JA Solar JAM72S09-385/PR (385.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define JA Solar JAM72S09-385/PR?
Dataset percentiles tracking JA Solar JAM72S09-385/PR power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for JA Solar JAM72S09-385/PR?
Benchmark highlights for JA Solar JAM72S09-385/PR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
385.0 W STC · Higher Than 49.1%
385.0 W STC (equal to all-CEC median) vs 410.0 W Mono-c-Si median.
19.85% Aperture Efficiency
Power density 198.5 W/m2 (0.06 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.64 V at -10 C (590.0 V string) and 54.95 V at -20 C (10 max).
21 Panels = 8,085 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,539 W PTC; NEC 690.8 OCPD floor is 15.87 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.04 * (1 + (-0.268/100) * (-10 - 25)) = 53.64 V | OCPD = 1.56 * 10.17 = 15.87 A
Inputs from CEC Modules.csv for JA Solar JAM72S09-385/PR: Voc=49.04 V, beta_Voc=-0.268%/C, Isc=10.17 A, STC=385.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (590.0 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for JA Solar JAM72S09-385/PR?
Official CEC datasheet figures for JA Solar JAM72S09-385/PR (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 385.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 359.0 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.04 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.17 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.9 V / 9.65 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.85% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM72S09-385/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many JA Solar JAM72S09-385/PR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.16 kW | 334 sq ft | $1,542 | $2,607 |
| 8 kW Class | 21 | 8.09 kW | 439 sq ft | $2,025 | $3,424 |
| 10 kW Class | 26 | 10.01 kW | 543 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Consolidated JA Solar wattage variants sharing the JA Solar JAM72S09-385/PR mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM72S09-375/PR | 375.0 W | 349.4 W | 48.47 V | 39.27 V | 19.35% |
| JA Solar JAM72S09-380/PR | 380.0 W | 354.2 W | 48.75 V | 39.59 V | 19.61% |
| JA Solar JAM72S09-385/PR | 385.0 W | 359.0 W | 49.04 V | 39.9 V | 19.85% |
| JA Solar JAM72S09-390/PR | 390.0 W | 363.8 W | 49.35 V | 40.21 V | 20.12% |
| JA Solar JAM72S09-395/PR | 395.0 W | 368.6 W | 49.64 V | 40.48 V | 20.38% |
How Many JA Solar JAM72S09-385/PR Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM72S09-385/PR (53.64 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.95 V | 10 panels | 549.5 V | 18 panels |
| -10 C (14 F) | 53.64 V | 11 panels | 590.0 V | 18 panels |
| 0 C (32 F) | 52.33 V | 11 panels | 575.6 V | 19 panels |
| 25 C (77 F STC) | 49.04 V | 12 panels | 588.5 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72S09-385/PR?
Competing CEC solar panels closest to JA Solar JAM72S09-385/PR in nameplate wattage and Voc, starting with EMMVEE Photovoltaic Power Private Limited E385M72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| EMMVEE Photovoltaic Power Private Limited E385M72 EMMVEE Photovoltaic Power Private Limited |
385.0 W | Tie (0 W) | 48.9 V | 19.32% | 92.0% |
| Boviet Solar Technology Co Ltd BVM6612M-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-385-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.5 V | 19.85% | 93.1% |
| Boviet Solar Technology Co Ltd BVM6612M-385L-H Boviet Solar Technology Co Ltd |
385.0 W | Tie (0 W) | 48.45 V | 19.35% | 93.2% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM72S09-385/PR?
Evaluate JA Solar JAM72S09-385/PR (385.0 W STC, 49.04 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72S09-385/PR reaches 54.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 21 panels (439 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM72S09-385/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM72S09-385/PR 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare EMMVEE Photovoltaic Power Private Limited E385M72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM72S09-385/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM72S09-385/PR?
Multiplying JA Solar JAM72S09-385/PR's 10.17 A short-circuit current by 1.56 equals 15.87 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can JA Solar JAM72S09-385/PR pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.64 V cold Voc at 14 F and handles 10.17 A Isc; string inverters cap JA Solar JAM72S09-385/PR at 11 panels on 600 V.
Is JA Solar JAM72S09-385/PR eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM72S09-385/PR rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)